Corneal surface reconstruction algorithm using Zernike polynomial representation: improvements.

Recently Sicam et al. [J. Opt. Soc. Am. A21, 1300 (2004)] presented a new corneal reconstruction algorithm for estimating corneal sag by Zernike polynomials. An equivalent but simpler derivation of the model equations is presented. The algorithm is tested on a sphere, a conic, and a toric. These tests reveal significant height errors that accrue with distance from the corneal apex. Additional postprocessing steps are introduced to circumvent these errors. A consistent and significant reduction in height errors is observed across the test surfaces. Finally, Sicam used the conic p-value p as a measure of algorithm efficacy. Further investigation shows that the finite Zernike representation affected the reported results. The p-value should therefore be used with caution as an efficacy measure.

[1]  Jason Turuwhenua,et al.  A Novel Low-Order Method for Recovery of the Corneal Shape , 2004, Optometry and vision science : official publication of the American Academy of Optometry.

[2]  Joris Coppens,et al.  Corneal surface reconstruction algorithm that uses Zernike polynomial representation. , 2004, Journal of the Optical Society of America. A, Optics, image science, and vision.

[3]  S. Klein,et al.  Axial Curvature and the Skew Ray Error in Corneal Topography , 1997, Optometry and vision science : official publication of the American Academy of Optometry.

[4]  Henri E. Bal,et al.  Real-time, adaptive measurement of corneal shapes , 2002, Comput. Sci. Eng..

[5]  S A Klein,et al.  A spline surface algorithm for reconstruction of corneal topography from a videokeratographic reflection pattern. , 1995, Optometry and vision science : official publication of the American Academy of Optometry.

[6]  J. M. Miller,et al.  Representation of videokeratoscopic height data with Zernike polynomials. , 1995, Journal of the Optical Society of America. A, Optics, image science, and vision.

[7]  Frans C. A. Groen,et al.  A new instrument to measure the shape of the cornea based on pseudo random colour coding , 1997 .

[8]  R A Applegate,et al.  Mathematical Model of a Placido Disk Keratometer and Its Implications for Recovery of Corneal Topography , 1997, Optometry and vision science : official publication of the American Academy of Optometry.

[9]  S A Klein Corneal Topography Reconstruction Algorithm that Avoids the Skew Ray Ambiguity and the Skew Ray Error , 1997, Optometry and vision science : official publication of the American Academy of Optometry.

[10]  Howard C. Howland,et al.  Noninvasive measurement of corneal topography , 1995 .

[11]  R. Ambrósio,et al.  Computerized Corneal Topography and Its Importance to Wavefront Technology , 2001, Cornea.