Application of the unequal two-tone method for AM-AM and AM-PM characterization of MMIC power amplifiers
暂无分享,去创建一个
The unequal 2-tone method is reviewed and applied to K-Band MMIC power amplifiers. The technique can be used to simultaneously characterize AM-AM, AM-PM conversion coefficients and insertion phase under drive as well as estimate third order intermodulation ratio and intercept point. The method may be applied by making a simple modification to existing equal 2-tone or mixer test systems. Test results are presented in-fixture for a 1 W power amplifier MMIC at 22 GHz and on-wafer in a production environment for two 20 GHz power amplifier MMIC.
[1] Fadhel M. Ghannouchi,et al. A new unequal three-tone signal method for AM-AM and AM-PM distortion measurements suitable for characterization of satellite communication transmitters/transponders , 2000 .
[2] J. P. Laico,et al. A medium power traveling-wave tube for 6,000-mc radio relay , 1956 .