Enhancement of lateral flow assay performance by electromagnetic relocation of reporter particles

Lateral flow assays (LFAs) are a widely-used point-of care diagnostic format, but suffer from limited analytical sensitivity, especially when read by eye. It has recently been reported that LFA performance can be improved by using magnetic reporter particles and an external magnetic field applied at the test line. The mechanism of sensitivity/performance enhancement was suggested to be concentration/retardation of reporter particles at the test line. Here we demonstrate an additional mechanism of particle relocation where reporter particles from the lower depths of the translucent LFA strip relocate to more-visible locations nearer to the top surface, producing a more visible signal. With a magnetic field we observed an improvement in sensitivity of human chorionic gonadotropin (hCG) detection from 1.25 ng/mL to 0.31 ng/mL. We also observed an increase of the color intensity per particle in test lines when the magnetic field was present.

[1]  Richard C. Willson,et al.  Persistent Luminescence Strontium Aluminate Nanoparticles as Reporters in Lateral Flow Assays , 2014, Analytical chemistry.

[2]  Zhi-ping Zhang,et al.  Rapid detection of Bacillus anthracis spores using a super-paramagnetic lateral-flow immunological detection system. , 2013, Biosensors & bioelectronics.

[3]  Hongchen Gu,et al.  Development of lateral flow immunoassay system based on superparamagnetic nanobeads as labels for rapid quantitative detection of cardiac troponin I , 2009 .

[4]  Mingyuan Gao,et al.  Lateral flow immunochromatographic assay for sensitive pesticide detection by using Fe3O4 nanoparticle aggregates as color reagents. , 2011, Analytical chemistry.

[5]  Il-Hoon Cho,et al.  Ultrasensitive detection of microbial cells using magnetic focus enhanced lateral flow sensors. , 2016, Chemical communications.

[6]  Marco H Hefti,et al.  Rapid, high sensitivity, point-of-care test for cardiac troponin based on optomagnetic biosensor. , 2010, Clinica chimica acta; international journal of clinical chemistry.

[7]  Robert H Gilman,et al.  Development and Evaluation of a Magnetic Immunochromatographic Test To Detect Taenia solium, Which Causes Taeniasis and Neurocysticercosis in Humans , 2010, Clinical and Vaccine Immunology.

[8]  Andreas Manz,et al.  On-chip free-flow magnetophoresis: continuous flow separation of magnetic particles and agglomerates. , 2004, Analytical chemistry.

[9]  Nicole Pamme,et al.  Mobile magnetic particles as solid-supports for rapid surface-based bioanalysis in continuous flow. , 2009, Lab on a chip.

[10]  D. S. Hage,et al.  Studies on the rate and control of antibody oxidation by periodate. , 1995, Analytical biochemistry.

[11]  Kevin W Eliceiri,et al.  NIH Image to ImageJ: 25 years of image analysis , 2012, Nature Methods.

[12]  T. Morozova,et al.  Active bead-linked immunoassay on protein microarrays. , 2006, Analytica chimica acta.

[13]  Hongchen Gu,et al.  Study of superparamagnetic nanoparticles as labels in the quantitative lateral flow immunoassay , 2009 .

[14]  Ronald Laborde,et al.  Rapid detection of HIV-1 p24 antigen using magnetic immuno-chromatography (MICT). , 2009, Journal of virological methods.

[15]  M. Medina‐Sánchez,et al.  Improving sensitivity of gold nanoparticle-based lateral flow assays by using wax-printed pillars as delay barriers of microfluidics. , 2014, Lab on a chip.

[16]  Wen-Hsiang Chen,et al.  Functionalized viral nanoparticles as ultrasensitive reporters in lateral-flow assays. , 2013, The Analyst.

[17]  R. Niessner,et al.  Magnetic nanogold microspheres-based lateral-flow immunodipstick for rapid detection of aflatoxin B2 in food. , 2009, Biosensors & bioelectronics.

[18]  J. Conrad,et al.  Aptamer-Phage Reporters for Ultrasensitive Lateral Flow Assays. , 2015, Analytical chemistry.

[19]  Brendan O’Farrell,et al.  Evolution in Lateral Flow–Based Immunoassay Systems , 2008, Lateral Flow Immunoassay.

[20]  Geertruida A. Posthuma-Trumpie,et al.  Lateral flow (immuno)assay: its strengths, weaknesses, opportunities and threats. A literature survey , 2009, Analytical and bioanalytical chemistry.

[21]  W. Dittmer,et al.  Sensitive and rapid immunoassay for parathyroid hormone using magnetic particle labels and magnetic actuation. , 2008, Journal of immunological methods.

[22]  Maxim P Nikitin,et al.  Rapid dry-reagent immunomagnetic biosensing platform based on volumetric detection of nanoparticles on 3D structures. , 2016, Biosensors & bioelectronics.

[23]  Jonathan D Posner,et al.  Two orders of magnitude improvement in detection limit of lateral flow assays using isotachophoresis. , 2014, Analytical chemistry.

[24]  Li-Jun Bi,et al.  Detection of Bacillus anthracis spores by super-paramagnetic lateral-flow immunoassays based on "Road Closure". , 2015, Biosensors & bioelectronics.

[25]  T. Granade,et al.  Rapid Detection and Differentiation of Antibodies to HIV-1 and HIV-2 Using Multivalent Antigens and Magnetic Immunochromatography Testing , 2010, Clinical and Vaccine Immunology.

[26]  Richard C. Willson,et al.  Sensitive Detection of Norovirus Using Phage Nanoparticle Reporters in Lateral-Flow Assay , 2015, PloS one.

[27]  Mwj Menno Prins,et al.  Rapid integrated biosensor for multiplexed immunoassays based on actuated magnetic nanoparticles. , 2009, Lab on a chip.

[28]  Patrick E. Guire,et al.  Lateral flow immunoassay using magnetoresistive sensors , 2009 .

[29]  Susana Cardoso,et al.  GMR sensors and magnetic nanoparticles for immuno-chromatographic assays , 2012 .

[30]  L. Berendsen,et al.  Amorphous carbon nanoparticles: a versatile label for rapid diagnostic (immuno)assays , 2011, Analytical and Bioanalytical Chemistry.