Influence of cortical bone thickness and implant length on implant stability at the time of surgery--clinical, prospective, biomechanical, and imaging study.

This clinical study is the first to quantitatively evaluate both regional bone structure by computed tomography preoperatively and dental implant stability by resonance frequency analysis at the time of surgery to explore the relation between local bone structure and dental implant stability in humans. Implant stability at the time of installation is often difficult to achieve in lower density bone and implant stability might influence treatment efficacy. Few clinical studies have reported detailed bone characteristics obtained using computed tomography prior to surgery and comprehensive implant stability measurements at the time of surgery. We hypothesized that thicker cortical bone would improve the stability of the dental implant at the time of placement. Before radiographic examination, diagnostic radiographic templates were made by incorporating radiopaque indicators. Computed tomography scans were obtained for 50 edentulous subjects prior to surgery. Preoperatively, the thickness of the cortical bone at the sites of implant insertion was measured digitally, and then implant insertion surgery was performed. A total of 225-implant stability measurements were made using a resonance frequency analyzer. There was a strong linear correlation between cortical bone thickness and resonance frequency (r = 0.84, P < 0.0001). The implant length had a weak negative correlation with stability (r = -0.25, P < 0.0005). These results suggest that the initial stability at the time of implant installation is influenced more by cortical bone thickness than by implant length. The cortical and cancellous ratio of local bone is extremely important for implant stability at the time of surgery and determining the local bone condition is critical for treatment success.

[1]  J. Rubenstein,et al.  Ten-year results for Brånemark implants immediately loaded with fixed prostheses at implant placement. , 1997, The International journal of oral & maxillofacial implants.

[2]  R. Jaffin,et al.  The excessive loss of Branemark fixtures in type IV bone: a 5-year analysis. , 1991, Journal of periodontology.

[3]  L Sennerby,et al.  A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. , 1992, The International journal of oral & maxillofacial implants.

[4]  J Gunne,et al.  Osseointegrated implants in edentulous jaws: a 2-year longitudinal study. , 1990, The International journal of oral & maxillofacial implants.

[5]  Roger Watson,et al.  Tissue-integrated prostheses , 1985 .

[6]  S. R. Bryant The effects of age, jaw site, and bone condition on oral implant outcomes. , 1998, The International journal of prosthodontics.

[7]  J. Hirsch,et al.  Biological factors contributing to failures of osseointegrated oral implants. (I). Success criteria and epidemiology. , 1998, European journal of oral sciences.

[8]  I Herrmann,et al.  A multicenter study of overdentures supported by Brånemark implants. , 1993, The International journal of oral & maxillofacial implants.

[9]  B. Gantes,et al.  Bone density assessments of dental implant sites: 1. Quantitative computed tomography. , 2003, The International journal of oral & maxillofacial implants.

[10]  M. Quirynen,et al.  Impact of systemic diseases and medication on osseointegration. , 2003, Periodontology 2000.

[11]  L Sennerby,et al.  Stability assessments and histology of titanium implants placed simultaneously with autogenous onlay bone in the rabbit tibia. , 1998, International journal of oral and maxillofacial surgery.

[12]  G A Favero,et al.  Considerations preliminary to the application of early and immediate loading protocols in dental implantology. , 2000, Clinical oral implants research.

[13]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[14]  N. Lang,et al.  Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits. , 1996 .

[15]  L Sennerby,et al.  Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature. , 1998, The International journal of prosthodontics.

[16]  C. Gamble,et al.  Bone classification: an objective scale of bone density using the computerized tomography scan. , 2001, Clinical oral implants research.

[17]  J. Brunski Biomaterials and biomechanics in dental implant design. , 1988, The International journal of oral & maxillofacial implants.

[18]  L. Cooper,et al.  Immediate mandibular rehabilitation with endosseous implants: simultaneous extraction, implant placement, and loading. , 2002, The International journal of oral & maxillofacial implants.

[19]  John B. Brunski,et al.  In Vivo Bone Response to Biomechanical Loading at the Bone/Dental-Implant Interface , 1999, Advances in dental research.

[20]  Jean-Pierre Bernard,et al.  Predicting osseointegration by means of implant primary stability. , 2004, Clinical oral implants research.

[21]  L Sennerby,et al.  Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study. , 1999, International journal of oral and maxillofacial surgery.

[22]  T. Albrektsson,et al.  Aging, osteoporosis, and dental implants , 2002 .

[23]  M. Quirynen,et al.  Morphology and dimensions of the mandibular jaw bone in the interforaminal region in patients requiring implants in the distal areas. , 2003, Clinical oral implants research.

[24]  P. Branemark,et al.  Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. , 1977, Scandinavian journal of plastic and reconstructive surgery. Supplementum.

[25]  Rickard Brånemark,et al.  Biomechanical characterization of osseointegration: An experimental in vivo investigation in the beagle dog , 1998, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[26]  A. Gonshor,et al.  Retrospective multicenter analysis of 3i endosseous dental implants placed over a five-year period. , 1996, Clinical oral implants research.

[27]  K. Nilner,et al.  Early functional loading of Brånemark dental implants: 5-year clinical follow-up study. , 2000, Clinical implant dentistry and related research.

[28]  M. Ueda,et al.  A comparative study of removal torque of endosseous implants in the fibula, iliac crest and scapula of cadavers: preliminary report. , 1997, Clinical oral implants research.

[29]  L Sennerby,et al.  Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. , 2000, Clinical implant dentistry and related research.

[30]  U. Lekholm,et al.  Influence of mono- and bicortical anchorage on the integration of titanium implants. A study in the rabbit tibia. , 1996, International journal of oral and maxillofacial surgery.

[31]  J. Hirsch,et al.  Biological factors contributing to failures of osseointegrated oral implants. (II). Etiopathogenesis. , 1998, European journal of oral sciences.

[32]  P. Branemark,et al.  Brånemark Novum: a new treatment concept for rehabilitation of the edentulous mandible. Preliminary results from a prospective clinical follow-up study. , 1999, Clinical implant dentistry and related research.

[33]  U. Lekholm,et al.  Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits. , 1996, Clinical oral implants research.

[34]  P. Branemark,et al.  Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. , 1990, The International journal of oral & maxillofacial implants.

[35]  P Nilsson,et al.  Biomechanical characterization of osseointegration during healing: an experimental in vivo study in the rat. , 1997, Biomaterials.

[36]  N Meredith,et al.  A review of nondestructive test methods and their application to measure the stability and osseointegration of bone anchored endosseous implants. , 1998, Critical reviews in biomedical engineering.

[37]  P Missika,et al.  Optimal implant stabilization in low density bone. , 2001, Clinical oral implants research.

[38]  M. Tschabitscher,et al.  Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible. , 2003, Clinical oral implants research.

[39]  Saadoun Ap,et al.  Clinical results and guidelines on Steri-Oss endosseous implants. , 1992 .

[40]  Reinhilde Jacobs,et al.  Preoperative radiologic planning of implant surgery in compromised patients. , 2003, Periodontology 2000.