Method of applying internal standard to dried matrix spot samples for use in quantitative bioanalysis.

A novel technique is presented that addresses the issue of how to apply internal standard (IS) to dried matrix spot (DMS) samples that allows the IS to integrate with the sample prior to extraction. The TouchSpray, a piezo electric spray system, from The Technology Partnership (TTP), was used to apply methanol containing IS to dried blood spot (DBS) samples. It is demonstrated that this method of IS application has the potential to work in practice, for use in quantitative determination of circulating exposures of pharmaceuticals in toxicokinetic and pharmacokinetic studies. Three different methods of IS application were compared: addition of IS to control blood prior to DBS sample preparation (control 1), incorporation into extraction solvent (control 2), and the novel use of TouchSpray technology (test). It is demonstrated that there was no significant difference in accuracy and precision data using these three techniques obtained using both manual extraction and direct elution.

[1]  P. Abu-Rabie Direct analysis of DBS: emerging and desirable technologies , 2011 .

[2]  F. Fernández,et al.  Ambient sampling/ionization mass spectrometry: applications and current trends. , 2011, Analytical chemistry.

[3]  K. Heinig,et al.  Determination of oseltamivir (Tamiflu®) and oseltamivir carboxylate in dried blood spots using offline or online extraction. , 2011, Bioanalysis.

[4]  H. T. Karnes,et al.  Direct analysis of dried blood spots by in-line desorption combined with high-resolution chromatography and mass spectrometry for quantification of maple syrup urine disease biomarkers leucine and isoleucine , 2011, Analytical and bioanalytical chemistry.

[5]  J. McElnay,et al.  Metronidazole Population Pharmacokinetics in Preterm Neonates Using Dried Blood-Spot Sampling , 2011, Pediatrics.

[6]  Patrice Mangin,et al.  Automated system for on-line desorption of dried blood spots applied to LC/MS/MS pharmacokinetic study of flurbiprofen and its metabolite. , 2011, Journal of pharmaceutical and biomedical analysis.

[7]  M. Barfield,et al.  Use of dried plasma spots in the determination of pharmacokinetics in clinical studies: validation of a quantitative bioanalytical method. , 2011, Analytical chemistry.

[8]  Neil Spooner,et al.  The effect of hematocrit on assay bias when using DBS samples for the quantitative bioanalysis of drugs. , 2010, Bioanalysis.

[9]  P. Abu-Rabie,et al.  Study to assess the effect of age of control human and animal blood on its suitability for use in quantitative bioanalytical DBS methods. , 2010, Bioanalysis.

[10]  G. V. Van Berkel,et al.  Liquid microjunction surface sampling coupled with high-pressure liquid chromatography-electrospray ionization-mass spectrometry for analysis of drugs and metabolites in whole-body thin tissue sections. , 2010, Analytical chemistry.

[11]  S. Aburuz,et al.  A Simple Dried Blood Spot Assay for Therapeutic Drug Monitoring of Lamotrigine , 2010 .

[12]  Chester L. Bowen,et al.  Direct analysis of dried blood spots utilizing desorption electrospray ionization (DESI) mass spectrometry. , 2010, The Analyst.

[13]  P. Abu-Rabie,et al.  Direct quantitative bioanalysis of drugs in dried blood spot samples using a thin-layer chromatography mass spectrometer interface. , 2009, Analytical chemistry.

[14]  L. Stolk,et al.  Dried Blood Spot Methods in Therapeutic Drug Monitoring: Methods, Assays, and Pitfalls , 2009, Therapeutic drug monitoring.

[15]  M. Barfield,et al.  Dried blood spots as a sample collection technique for the determination of pharmacokinetics in clinical studies: considerations for the validation of a quantitative bioanalytical method. , 2009, Analytical chemistry.

[16]  O. Ovchinnikova,et al.  Established and emerging atmospheric pressure surface sampling/ionization techniques for mass spectrometry. , 2008, Journal of mass spectrometry : JMS.

[17]  Neil Spooner,et al.  Application of dried blood spots combined with HPLC-MS/MS for the quantification of acetaminophen in toxicokinetic studies. , 2008, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[18]  Vinod P. Shah,et al.  Bioanalytical Method Validation—A Revisit with a Decade of Progress , 2000, Pharmaceutical Research.