Reducing the effects of acoustic heterogeneity with an iterative reconstruction method from experimental data in microwave induced thermoacoustic tomography.

PURPOSE An iterative reconstruction method has been previously reported by the authors of this paper. However, the iterative reconstruction method was demonstrated by solely using the numerical simulations. It is essential to apply the iterative reconstruction method to practice conditions. The objective of this work is to validate the capability of the iterative reconstruction method for reducing the effects of acoustic heterogeneity with the experimental data in microwave induced thermoacoustic tomography. METHODS Most existing reconstruction methods need to combine the ultrasonic measurement technology to quantitatively measure the velocity distribution of heterogeneity, which increases the system complexity. Different to existing reconstruction methods, the iterative reconstruction method combines time reversal mirror technique, fast marching method, and simultaneous algebraic reconstruction technique to iteratively estimate the velocity distribution of heterogeneous tissue by solely using the measured data. Then, the estimated velocity distribution is used subsequently to reconstruct the highly accurate image of microwave absorption distribution. Experiments that a target placed in an acoustic heterogeneous environment are performed to validate the iterative reconstruction method. RESULTS By using the estimated velocity distribution, the target in an acoustic heterogeneous environment can be reconstructed with better shape and higher image contrast than targets that are reconstructed with a homogeneous velocity distribution. CONCLUSIONS The distortions caused by the acoustic heterogeneity can be efficiently corrected by utilizing the velocity distribution estimated by the iterative reconstruction method. The advantage of the iterative reconstruction method over the existing correction methods is that it is successful in improving the quality of the image of microwave absorption distribution without increasing the system complexity.

[1]  Vasilis Ntziachristos,et al.  Statistical optoacoustic image reconstruction using a-priori knowledge on the location of acoustic distortions , 2011 .

[2]  Bradley E. Treeby,et al.  Artifact Trapping During Time Reversal Photoacoustic Imaging for Acoustically Heterogeneous Media , 2010, IEEE Transactions on Medical Imaging.

[3]  Lihong V. Wang,et al.  Enhancement of photoacoustic tomography by ultrasonic computed tomography based on optical excitation of elements of a full-ring transducer array. , 2013, Optics letters.

[4]  Qing Huo Liu,et al.  RECONSTRUCTION OF MICROWAVE ABSORPTION PROPERTIES IN HETEROGENEOUS TISSUE FOR MICROWAVE-INDUCED THERMO-ACOUSTIC TOMOGRAPHY , 2012 .

[5]  M. Lindstrom,et al.  A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries , 2007, Physics in medicine and biology.

[6]  Da Xing,et al.  Thermoacoustic molecular tomography with magnetic nanoparticle contrast agents for targeted tumor detection. , 2010, Medical physics.

[7]  Barry D. Van Veen,et al.  Development of Anatomically Realistic Numerical Breast Phantoms With Accurate Dielectric Properties for Modeling Microwave Interactions With the Human Breast , 2008, IEEE Transactions on Biomedical Engineering.

[8]  Qing Huo Liu,et al.  AN INTEGRATED SIMULATION APPROACH AND EXPERIMENTAL RESEARCH ON MICROWAVE INDUCED THERMO-ACOUSTIC TOMOGRAPHY SYSTEM , 2013 .

[9]  Zhengrong Liang,et al.  Haustral Fold Segmentation With Curvature-Guided Level Set Evolution , 2013, IEEE Transactions on Biomedical Engineering.

[10]  D. Xing,et al.  The feasibility of using microwave-induced thermoacoustic tomography for detection and evaluation of renal calculi , 2010, Physics in Medicine and Biology.

[11]  Mark A. Anastasio,et al.  3D laser optoacoustic ultrasonic imaging system for research in mice (LOUIS-3DM) , 2014, Photonics West - Biomedical Optics.

[12]  Hao Xin,et al.  Microwave-Induced Thermoacoustic Imaging Model for Potential Breast Cancer Detection , 2012, IEEE Transactions on Biomedical Engineering.

[13]  S. Sanei Characterisation of fat and malignancy in transmissive ultrasound breast tomographs applying fuzzy logic , 1998, Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286).

[14]  Zaiping Nie,et al.  A prototype system of microwave induced thermo-acoustic tomography for breast tumor , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[15]  Haijiang Zhang,et al.  An improved automatic time-of-flight picker for medical ultrasound tomography. , 2009, Ultrasonics.

[16]  Yuan Xu,et al.  Effects of acoustic heterogeneity in breast thermoacoustic tomography , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  Qing Huo Liu,et al.  Microwave-Induced Thermal Acoustic Tomography for Breast Tumor Based on Compressive Sensing , 2013, IEEE Transactions on Biomedical Engineering.

[18]  Wiendelt Steenbergen,et al.  Speed-of-sound compensated photoacoustic tomography for accurate imaging. , 2012, Medical physics.

[19]  Lorenzo Crocco,et al.  An Effective Procedure for MNP-Enhanced Breast Cancer Microwave Imaging , 2014, IEEE Transactions on Biomedical Engineering.

[20]  Yulia Hristova,et al.  Time reversal in thermoacoustic tomography—an error estimate , 2008, 0812.0606.

[21]  Vasilis Ntziachristos,et al.  Near-field thermoacoustic tomography of small animals , 2011, Physics in medicine and biology.

[22]  Xu Li,et al.  Toward Carbon-Nanotube-Based Theranostic Agents for Microwave Detection and Treatment of Breast Cancer: Enhanced Dielectric and Heating Response of Tissue-Mimicking Materials , 2010, IEEE Transactions on Biomedical Engineering.

[23]  D. Xing,et al.  Three-dimensional thermoacoustic imaging for early breast cancer detection. , 2012, Medical physics.

[24]  Ryan J Halter,et al.  The correlation of in vivo and ex vivo tissue dielectric properties to validate electromagnetic breast imaging: initial clinical experience , 2009, Physiological measurement.

[25]  Klaus Mueller,et al.  Refraction corrected transmission ultrasound computed tomography for application in breast imaging. , 2010, Medical physics.

[26]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.

[27]  Linh V. Nguyen,et al.  Reconstruction and time reversal in thermoacoustic tomography in acoustically homogeneous and inhomogeneous media , 2008 .

[28]  S. Hagness,et al.  Toward contrast-enhanced microwave-induced thermoacoustic imaging of breast cancer: an experimental study of the effects of microbubbles on simple thermoacoustic targets , 2009, Physics in medicine and biology.

[29]  M. Lindstrom,et al.  A large-scale study of the ultrawideband microwave dielectric properties of normal breast tissue obtained from reduction surgeries , 2007, Physics in medicine and biology.

[30]  N. Duric,et al.  Detection of breast cancer with ultrasound tomography: first results with the Computed Ultrasound Risk Evaluation (CURE) prototype. , 2007, Medical physics.

[31]  Lihong V. Wang,et al.  Thermoacoustic tomography with correction for acoustic speed variations , 2006, Physics in medicine and biology.

[32]  Da Xing,et al.  Microwave-induced thermoacoustic computed tomography with a clinical contrast agent of NMG2[Gd(DTPA)] , 2012 .