Outcomes Following Temporary Kapandji Pinning Technique and Distal Radial LCP Fixation for Intra-Articular Fractures of the Displaced Distal Radius

In partially or completely displaced intra-articular fracture of the distal radius , achieving satisfactory reduction and maintenance of good reduction before applying the plate may be difficult. Especially to accomplish the anatomic volar tilt remains a problem. Typically, the Kapandji technique has been described to reduce and stabilize a large displaced and extra-articular fracture of the distal radius. We present the results of a prospective series using the temporary Kapandji technique for K-wire intrafocal fixation followed by rigid fixation with distal radial locking compression plate. The mean follow-up period totaled 12 months. A total of 57 patients were evaluated by radiographic and clinical review. The modified Mayo wrist score was used for postoperative patient evaluation. The clinical results on follow-up were good to excellent. Minimal joint stiffness and functional outcomes of the wrist and elbow were satisfactory. Statically significant differences were found between the preoperative and postoperative radiologic parameters. No skin infection due to K-wire insertion was noted, and the fracture healed completely in every case. This paper reports the results of 57 cases of intra-articular fractures of the distal radius treated by Kapandji wires as a reduction tool and definitive fixation by the application of a locked volar plate. It could be performed easily and reliably. K-wires were used to temporarily maintain reduction throughout the rigid fixation without further displacement in the follow-up clinic. The results proved appropriate, and the technique has merit, as it obviates the need for dorsal exposure in most cases.

[1]  Y. Abe,et al.  Arthroscopic-Assisted Reduction of Intra-articular Distal Radius Fracture. , 2017, Hand clinics.

[2]  S. Asadollahi,et al.  Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature , 2013, Journal of Orthopaedics and Traumatology.

[3]  J. Birkmeyer,et al.  Variations in the use of internal fixation for distal radial fracture in the United States medicare population. , 2011, The Journal of bone and joint surgery. American volume.

[4]  S. Nicol,et al.  Should unstable extra-articular distal radial fractures be treated with fixed-angle volar-locked plates or percutaneous Kirschner wires? A prospective randomised controlled trial. , 2011, Injury.

[5]  C. Orces,et al.  Epidemiology of fall related forearm and wrist fractures among adults treated in US hospital emergency departments , 2010, Injury Prevention.

[6]  C. Court-Brown,et al.  Nonoperative fracture treatment in the modern era. , 2010, The Journal of trauma.

[7]  A. Devitt,et al.  Radiological outcomes of distal radius extra-articular fragility fractures treated with extra-focal kirschner wires. , 2010, Injury.

[8]  M. Swiontkowski Functional Outcomes for Unstable Distal Radial Fractures Treated with Open Reduction and Internal Fixation or Closed Reduction and Percutaneous Fixation: A Prospective Randomized Trial , 2010 .

[9]  O. Franko,et al.  Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial. , 2009, The Journal of bone and joint surgery. American volume.

[10]  M. Hofbauer,et al.  Volar fixed-angle plate osteosynthesis of unstable distal radius fractures: 12 months results , 2009, Archives of Orthopaedic and Trauma Surgery.

[11]  S. Trigg Fluoroscopic Evaluation of Intra-Articular Screw Placement During Locked Volar Plating of the Distal Radius: A Cadaveric Study , 2009 .

[12]  E. Akelman,et al.  Fluoroscopic evaluation of intra-articular screw placement during locked volar plating of the distal radius: a cadaveric study. , 2008, The Journal of hand surgery.

[13]  Mohit Bhandari,et al.  Variability in the assessment of fracture-healing in orthopaedic trauma studies. , 2008, The Journal of bone and joint surgery. American volume.

[14]  K. Chung,et al.  Treatment of unstable distal radial fractures with the volar locking plating system. , 2006, The Journal of bone and joint surgery. American volume.

[15]  C. Court-Brown,et al.  Epidemiology of adult fractures: A review. , 2006, Injury.

[16]  E. Panagiotopoulos,et al.  Correlation between radiological parameters and patient-rated wrist dysfunction following fractures of the distal radius. , 2005, Injury.

[17]  T. Azzopardi,et al.  Unstable extra-articular fractures of the distal radius: a prospective, randomised study of immobilisation in a cast versus supplementary percutaneous pinning. , 2005, The Journal of bone and joint surgery. British volume.

[18]  M. Henry,et al.  Volar Fixed‐Angle Plating of the Distal Radius , 2005, The Journal of the American Academy of Orthopaedic Surgeons.

[19]  K. Chung,et al.  Intrafocal Pinning of Distal Radius Fractures: A Simplified Approach , 2002, Annals of plastic surgery.

[20]  T. Henmi,et al.  Fractures of the Distal End of Radius in Elderly Patients: A Comparative Study of Anatomical and Functional Results , 2002, Journal of orthopaedic surgery.

[21]  P. Nicholson,et al.  The unstable distal radial fracture one year post Kapandji intrafocal pinning. , 1999, Injury.

[22]  D. Goutallier,et al.  Trans-styloid fixation of fractures of the distal radius. A prospective randomized comparison between 6- and 1-week postoperative immobilization in 60 fractures. , 1999, Acta orthopaedica Scandinavica.

[23]  P. Broos,et al.  Kapandji pinning or closed reduction for extra-articular distal radius fractures. , 1998, The Journal of trauma.

[24]  J. Kingma,et al.  K-wire fixation for redislocated Colles' fractures. Malunion in 8/21 cases. , 1997, Acta orthopaedica Scandinavica.

[25]  A. Palmer,et al.  The effect of dorsally angulated distal radius fractures on distal radioulnar joint congruency and forearm rotation. , 1996, The Journal of hand surgery.

[26]  A. Freeland,et al.  Buttress Pinning in the Unstable Distal Radial Fracture , 1995, Journal of hand surgery.

[27]  K. An,et al.  Functional ranges of motion of the wrist joint. , 1991, The Journal of hand surgery.

[28]  M. McQueen,et al.  Colles fracture: does the anatomical result affect the final function? , 1988, The Journal of bone and joint surgery. British volume.

[29]  I. Stockley,et al.  Fractures of the Distal Radius Intermediate and End Results in Relation to Radiologic Parameters , 1987, Clinical orthopaedics and related research.

[30]  A. Kapandji L'embrochage intra-focal des fractures de l'extrémité inférieure du radius dix ans après , 1987 .

[31]  R. L. Linscheid,et al.  Difficult wrist fractures. Perilunate fracture-dislocations of the wrist. , 1987, Clinical orthopaedics and related research.

[32]  R. Ericson,et al.  Colles' fracture. How should its displacement be measured and how should it be immobilized? , 1981, The Journal of bone and joint surgery. American volume.

[33]  J. Dowling,et al.  Comminuted Colles' fractures. Evaluation of a method of treatment. , 1961, The Journal of bone and joint surgery. American volume.