The effect of shear on in vitro platelet and leukocyte material-induced activation

The failure to understand the mechanisms of biomaterial-associated thrombosis prevents us from improving the blood compatibility of stents and mechanical heart valves. Blood-material interactions trigger a complex series of events and anticoagulant and anti-platelet therapies are needed to reduce the risks of thrombotic complications with most cardiovascular materials. While material interaction with platelets has been widely studied, little is currently known on material-induced leukocyte activation in the presence of shear. In vitro experiments were performed to assess the effect of flow on blood cell activation induced by medical grade metals, ST316L and TiAl6V4. Blood was circulated in flow chambers preloaded with or without metal wires at shear rates of 100, 500, and 1500 s−1. Platelet and leukocyte activation, leukocyte-platelet aggregation, and tissue factor expression on monocytes were measured by flow cytometry. Metal surfaces were characterized by scanning electron microscopy. Under physiological shear rates, no significant platelet microparticle formation was observed. However, significant CD11b up-regulation, leukocyte-platelet aggregates, and tissue factor expression were observed at 100 s−1. As shear rate increased to 1500 s−1, leukocyte activation reduced to control values. TiAl6V4-induced leukocyte activation was generally lower than that of ST316L. Adhesion significantly decreased with increasing shear rate to 1500 s−1. In blood, increase within physiological shear rates led to a significant reduction in in vitro material-induced leukocyte activation, suggesting that difference between material biocompatibility may be better identified at low shear rates or under pathological shear conditions.

[1]  M. Sefton,et al.  Leukocyte activation and leukocyte procoagulant activities after blood contact with polystyrene and polyethylene glycol-immobilized polystyrene beads. , 2001, The Journal of laboratory and clinical medicine.

[2]  S. Heo,et al.  Osseointegration of anodized titanium implants under different current voltages: a rabbit study. , 2007, Journal of oral rehabilitation.

[3]  Arnan Mitchell,et al.  A shear gradient–dependent platelet aggregation mechanism drives thrombus formation , 2009, Nature Medicine.

[4]  Patrick W Serruys,et al.  Coronary stents: looking forward. , 2010, Journal of the American College of Cardiology.

[5]  A. Branzi,et al.  Monocyte-derived tissue factor contributes to stent thrombosis in an in vitro system. , 2004, Journal of the American College of Cardiology.

[6]  J. Lausmaa,et al.  Interactions between human whole blood and modified TiO2-surfaces: influence of surface topography and oxide thickness on leukocyte adhesion and activation. , 2001, Biomaterials.

[7]  James M. Anderson,et al.  Inhibition of bacterial and leukocyte adhesion under shear stress conditions by material surface chemistry , 2003, Journal of biomaterials science. Polymer edition.

[8]  C. Kessler,et al.  Flow-based measurements of von Willebrand factor (VWF) function: binding to collagen and platelet adhesion under physiological shear rate. , 2010, Thrombosis research.

[9]  C. Claussen,et al.  Thrombogenicity of various endovascular stent types: an in vitro evaluation. , 2002, Journal of vascular and interventional radiology : JVIR.

[10]  P. Davies,et al.  Hemodynamically Driven Stent Strut Design , 2009, Annals of Biomedical Engineering.

[11]  S. Goto,et al.  Platelet surface P-selectin molecules increased after exposing platelet to a high shear flow. , 2000, International angiology : a journal of the International Union of Angiology.

[12]  Shaun P Jackson,et al.  Shear-dependent tether formation during platelet translocation on von Willebrand factor. , 2002, Blood.

[13]  Emir Baki Denkbaş,et al.  In vitro biocompatibility of plasma-aided surface-modified 316L stainless steel for intracoronary stents , 2010, Biomedical materials.

[14]  Y. Sakai,et al.  Stent-Induced Expression and Activation of the Leukocyte Integrin Mac-1 Is Associated With Neointimal Thickening and Restenosis , 2003, Circulation.

[15]  S. Usami,et al.  Analysis of the effect of disturbed flow on monocytic adhesion to endothelial cells. , 2002, Journal of biomechanics.

[16]  N. Nomura,et al.  In vitro short-term platelet adhesion on various metals , 2009, Journal of Artificial Organs.

[17]  J. Hathcock Flow effects on coagulation and thrombosis. , 2006, Arteriosclerosis, thrombosis, and vascular biology.

[18]  J. Brash,et al.  A cone-and-plate device for the investigation of platelet biomaterial interactions. , 1997, Journal of biomedical materials research.

[19]  Yutaka Komai,et al.  Mechanotransduction in leukocyte activation: a review. , 2007, Biorheology.

[20]  A. Tárnok,et al.  Rapid in vitro biocompatibility assay of endovascular stents by flow cytometry using platelet activation and platelet-leukocyte aggregation. , 1999, Cytometry.

[21]  C. Gemmell,et al.  Platelet interactions with titanium: modulation of platelet activity by surface topography. , 2001, Biomaterials.

[22]  T. Tamaki,et al.  Reduced platelet adhesion to titanium metal coated with apatite, albumin-apatite composite or laminin-apatite composite. , 2005, Biomaterials.

[23]  F. Luscinskas,et al.  Neutrophil Recruitment under Shear Flow: It's All about Endothelial Cell Rings and Gaps , 2009, Microcirculation.

[24]  C. Kirkpatrick,et al.  Modification of human polymorphonuclear neutrophilic cell (PMN)-adhesion on biomaterial surfaces by protein preadsorption under static and flow conditions , 2003, Journal of materials science. Materials in medicine.

[25]  P. Tengvall,et al.  The ability of surface characteristics of materials to trigger leukocyte tissue factor expression. , 2010, Biomaterials.

[26]  Claus Harder,et al.  Silicon carbide coating of nitinol stents to increase antithrombogenic properties and reduce nickel release. , 2008, Cardiovascular revascularization medicine : including molecular interventions.

[27]  W. Kao,et al.  Evaluation of leukocyte adhesion on polyurethanes: the effects of shear stress and blood proteins. , 2000, Biomaterials.

[28]  S. Hayakawa,et al.  Platelet adhesion on titanium oxide gels: effect of surface oxidation. , 2004, Biomaterials.

[29]  宮崎 泰彦 High shear stress can initiate both platelet aggregation and shedding of procoagulant containing microparticles , 1999 .

[30]  P. Walker,et al.  Disturbed flow promotes deposition of leucocytes from flowing whole blood in a model of a damaged vessel wall , 2004, British journal of haematology.

[31]  M. Sefton,et al.  Material-induced tissue factor expression but not CD11b upregulation depends on the presence of platelets. , 2003, Journal of biomedical materials research. Part A.

[32]  P. Hjemdahl,et al.  Platelet-leukocyte aggregation under shear stress: Differential involvement of selectins and integrins , 2003, Thrombosis and Haemostasis.

[33]  Wolfgang Schramm,et al.  Mechanism of platelet adhesion to von Willebrand factor and microparticle formation under high shear stress. , 2006, Blood.

[34]  O. McCarty,et al.  Preferential binding of platelets to monocytes over neutrophils under flow. , 2005, Biochemical and biophysical research communications.

[35]  K S Sakariassen,et al.  Shear-induced platelet activation and platelet microparticle formation at blood flow conditions as in arteries with a severe stenosis. , 1997, Arteriosclerosis, thrombosis, and vascular biology.

[36]  T. Hansen,et al.  Modification of human platelet adhesion on biomaterial surfaces by protein preadsorption under static and flow conditions , 2004, Journal of materials science. Materials in medicine.

[37]  D. Agrawal,et al.  In stent restenosis: bane of the stent era , 2006, Journal of Clinical Pathology.