Structure Optimization of Force Feedback Device in Virtual Cardiovascular Surgery

In virtual cardiovascular surgery, the force feedback is transmitted via the flexible guide wire. In the force transmission, disturbance always occurs due to flexible deformation, and this would make it hard to ensure immersion by rendering the force feedback in actuator. As the effect of flexible deformation is related to the length of guide wire, experiment is designed to assess the force transmission of guide wire when the length between the actuator and operating point changes. In this paper, three indexes are proposed to search for the length between the actuator and the device entrance. And the optimal scope length of guide wire is found out to ensure the guide wire has the best performance for the force transmission.

[1]  Fernando Bello,et al.  Real-time guidewire simulation in complex vascular models , 2009, The Visual Computer.

[2]  Hans Knutsson,et al.  Simulation of Patient Specific Cervical Hip Fracture Surgery With a Volume Haptic Interface , 2008, IEEE Transactions on Biomedical Engineering.

[3]  Derek Gould,et al.  A realistic elastic rod model for real-time simulation of minimally invasive vascular interventions , 2010, The Visual Computer.

[4]  P. Polygerinos,et al.  Triaxial Catheter-Tip Force Sensor for MRI-Guided Cardiac Procedures , 2013, IEEE/ASME Transactions on Mechatronics.

[5]  C. Karaliotas,et al.  When simulation in surgical training meets virtual reality , 2011 .

[6]  Wiro J. Niessen,et al.  Simulation of Guide Wire Propagation for Minimally Invasive Vascular Interventions , 2002, MICCAI.

[7]  Shih-Tseng Lee,et al.  Development of an Augmented Reality Force Feedback Virtual Surgery Training Platform , 2011 .

[8]  Moharam Habibnejad Korayem,et al.  AFM Based Nano Telemanipulation for Indenting on the Human Chromosomes Using the Sliding Mode Impedance Controller , 2012 .

[9]  Allison M. Okamura,et al.  Force modeling for needle insertion into soft tissue , 2004, IEEE Transactions on Biomedical Engineering.

[10]  Gábor Székely,et al.  Evaluation of a new virtual-reality training simulator for hysteroscopy , 2009, Surgical Endoscopy.

[11]  Marlies P. Schijven,et al.  European consensus on a competency-based virtual reality training program for basic endoscopic surgical psychomotor skills , 2010, Surgical Endoscopy.

[12]  Lixu Gu,et al.  Computerized Medical Imaging and Graphics a Hybrid Deformable Model for Real-time Surgical Simulation , 2022 .

[13]  Yeong-Hwa Chang,et al.  Development scheme of haptic-based system for interactive deformable simulation , 2010, Comput. Aided Des..

[14]  John Kenneth Salisbury,et al.  Stability of Haptic Rendering: Discretization, Quantization, Time Delay, and Coulomb Effects , 2006, IEEE Transactions on Robotics.

[15]  Theo Arts,et al.  Computational modeling of volumetric soft tissue growth: application to the cardiac left ventricle , 2009, Biomechanics and modeling in mechanobiology.

[16]  Yuan-Shin Lee,et al.  Investigating Human Performance in a Virtual Reality Haptic Simulator as Influenced by Fidelity and System Latency , 2012, IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans.

[17]  Thenkurussi Kesavadas,et al.  Design and fabrication of a robotic mechanism for remote steering and positioning of interventional devices , 2010, The international journal of medical robotics + computer assisted surgery : MRCAS.

[18]  P. Lanzer,et al.  Catheter-based cardiovascular interventions , 2013 .

[19]  Libin Zhang,et al.  Measurement Performance Assessment: Dynamic Calibration Compared with Static Calibration Method for Roller Tester of Vehicle Brake Force , 2014 .

[20]  Blake Hannaford,et al.  Control law design for haptic interfaces to virtual reality , 2002, IEEE Trans. Control. Syst. Technol..

[21]  Shuxiang Guo,et al.  A novel master-slave robotic catheter system for Vascular Interventional Surgery , 2013, 2013 IEEE International Conference on Mechatronics and Automation.

[22]  Gang Wang,et al.  State control of a 12 DOF mobile manipulator via centroid feedback , 2013 .

[23]  Grigore C. Burdea,et al.  The Rutgers Master II-new design force-feedback glove , 2002 .

[24]  C. Duriez,et al.  New approaches to catheter navigation for interventional radiology simulation , 2006, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[25]  Walter Herzog,et al.  Feedback controlled force enhancement and activation reduction of voluntarily activated quadriceps femoris during sub-maximal muscle action. , 2012, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[26]  Yuru Zhang,et al.  Toward In-Vivo Force and Motion Measurement for Vascular Surgery , 2014, IEEE Transactions on Instrumentation and Measurement.

[27]  Farid Ferguene,et al.  Dynamic External Force Feedback Loop Control of a Robot Manipulator Using a Neural Compensator—Application to the Trajectory Following in an Unknown Environment , 2009, Int. J. Appl. Math. Comput. Sci..

[28]  E. Grinspun,et al.  Discrete elastic rods , 2008, SIGGRAPH 2008.

[29]  Steven D. Wexner,et al.  Review of available methods of simulation training to facilitate surgical education , 2010, Surgical Endoscopy.

[30]  William M. Wells,et al.  Medical Image Computing and Computer-Assisted Intervention — MICCAI’98 , 1998, Lecture Notes in Computer Science.

[31]  Lucy Y. Pao,et al.  Isotropic force control for haptic interfaces , 2004 .

[32]  Tianmiao Wang,et al.  Vascular deformation for vascular interventional surgery simulation , 2010, The international journal of medical robotics + computer assisted surgery : MRCAS.

[33]  Doug A. Bowman,et al.  Evaluating Display Fidelity and Interaction Fidelity in a Virtual Reality Game , 2012, IEEE Transactions on Visualization and Computer Graphics.

[34]  Katherine J. Kuchenbecker,et al.  Improving contact realism through event-based haptic feedback , 2006, IEEE Transactions on Visualization and Computer Graphics.

[35]  L. Jones Kinesthetic Sensing , 2000 .

[36]  Hui-Nam Pak,et al.  Development of a force-reflecting robotic platform for cardiac catheter navigation. , 2010, Artificial organs.

[37]  Daehie Hong,et al.  Haptic-based resistance training machine and its application to biceps exercises , 2011 .

[38]  弗雷德里克·奥尔森 An interventional simulation device , 2003 .

[39]  Anthony G. Gallagher,et al.  Construct validation of a novel hybrid virtual-reality simulator for training and assessing laparoscopic colectomy; results from the first course for experienced senior laparoscopic surgeons , 2008, Surgical Endoscopy.