Image-guided neuro-endovascular interventional studies often require a high resolution image quality which requires the use of small focal-spot sizes. There is always a tradeoff while choosing focal-spot sizes. The use of small- focal-spots gives better spatial resolution but limits x-ray tube output and tube loading. The use of larger- focal-spots provides better heat dissipation capacity and higher x-ray output but gives rise to geometric blurring hence loss of spatial resolution. A method has been proposed which incorporates the use of the line-focus principle that can achieve a smaller projected focal-spot while keeping the actual focal-spot size as the medium focal-spot. Here the gantry is tilted to reduce the effective anode angle, hence the central axis is tilted producing a smaller projected focal-spot. This was tested by acquiring images of a Pipeline stent in the right jugular vein and a guidewire of a rabbit using a high-resolution CMOSbased fluoroscopic detector with 75um pixels. Also the gantry was tilted in the anode-cathode direction shifting the central axis to the anode side of the beam and the rabbit was aligned with the new perpendicular ray. Acquired images, for small focal-spot, medium focal-spot, and 7-degree tilted medium focal-spot were compared. While small focal-spot images demonstrated superior resolution, and both tilted and untilted medium focal spot images demonstrated lower noise due to the increased tube output the tilted medium focal spot images exhibited improved resolution. Line profiles and quantitative measures of generalized relative object detectability confirmed the advantage of the tilted medium focalspot method above all.
[1]
Ciprian N. Ionita,et al.
Graphics processing unit (GPU) implementation of image processing algorithms to improve system performance of the control acquisition, processing, and image display system (CAPIDS) of the micro-angiographic fluoroscope (MAF)
,
2012,
Medical Imaging.
[2]
Stephen Rudin,et al.
Overcoming x-ray tube small focal spot output limitations for high resolution region of interest imaging
,
2012,
Medical Imaging.
[3]
M Russ,et al.
New family of generalized metrics for comparative imaging system evaluation
,
2015,
Medical Imaging.
[4]
S Rudin,et al.
Relative object detectability (ROD): a new metric for comparing x-ray image detector performance for a specified object of interest
,
2014,
Medical Imaging.
[5]
M Russ,et al.
Focal spot size reduction using asymmetric collimation to enable reduced anode angles with a conventional angiographic x-ray tube for use with high resolution detectors
,
2017,
Medical Imaging.
[6]
Stephen Rudin,et al.
Experimental and theoretical performance analysis for a CMOS-based high resolution image detector
,
2014,
Medical Imaging.