A new methodology for identification of critical lines using damping sensitivity analysis

When an inter-area mode dominates a low-frequency oscillation in a stressed condition, control of the active power flow of interface lines, with compensating devices, can effectively reduce the electromechanical power oscillations. In general, interface lines in which inter-area oscillations are large are considered to be good locations for installation of compensating devices. A sensitivity analysis with respect to change in active power flow can provide an important factor in electric power system operation. This paper proposes a new methodology to calculate the damping sensitivity with respect to change in active power flow, which can be useful for accurate selection of critical lines from the viewpoint of small-signal stability. In the proposed methodology, a damping sensitivity index is used to select the critical lines to damp power system oscillations. This paper describes how to derive the damping sensitivity for the selected mode and illustrates an example applying the proposed algorithm to a simple two-area system and the New England 39-bus test system.

[1]  H. Ghasemi,et al.  Oscillatory stability limit prediction using stochastic subspace identification , 2006, IEEE Transactions on Power Systems.

[2]  P. Kundur,et al.  Power system stability and control , 1994 .

[3]  Pouyan Pourbeik,et al.  Damping and synchronizing torques induced on generators by FACTS stabilizers in multimachine power systems , 1996 .

[4]  H. F. Wang,et al.  Application of the controllable series compensator in damping power system oscillations , 1996 .

[5]  H. Ghasemi,et al.  On-Line Damping Torque Estimation and Oscillatory Stability Margin Prediction , 2007, IEEE Transactions on Power Systems.

[6]  M. Khammash,et al.  Sensitivity based structured singular value approach to stability robustness of power systems , 2000 .

[7]  H. F. Wang,et al.  Indices for selecting the best location of PSSs or FACTS-based stabilisers in multimachine power systems: a comparative study , 1997 .

[8]  Hiroshi Okamoto,et al.  A method for identification of effective locations of variable impedance apparatus on enhancement of steady-state stability in large scale power systems , 1995 .

[9]  H. F. Wang,et al.  Selection of robust installing locations and feedback signals of FACTS-based stabilizers in multi-machine power systems , 1999 .

[10]  Vijay Vittal,et al.  Effect of nonlinear modal interaction on control performance: use of normal forms technique in control design. II. Case studies , 1998 .

[11]  U.P. Mhaskar,et al.  Power oscillation damping using FACTS devices: modal controllability, observability in local signals, and location of transfer function zeros , 2006, IEEE Transactions on Power Systems.

[12]  Chung-Liang Chang,et al.  Experience with power system stabilizers in a longitudinal power system , 1995 .

[13]  Joe H. Chow,et al.  Concepts for design of FACTS controllers to damp power swings , 1995 .

[14]  M. Ghandhari,et al.  A Robust Control Strategy for Shunt and Series Reactive Compensators to Dame Electromechanical Oscillations , 2001, IEEE Power Engineering Review.

[15]  Arturo Roman Messina,et al.  An investigation on the use of power system stabilizers for damping inter-area oscillations in longitudinal power systems , 1998 .

[16]  Vijay Vittal,et al.  Effect of nonlinear modal interaction on control performance: use of normal forms technique in control design. I. General theory and procedure , 1998 .

[17]  N. Martins,et al.  Determination of suitable locations for power system stabilizers and static VAr compensators for damping electromechanical oscillations in large scale power systems , 1989, Conference Papers Power Industry Computer Application Conference.

[18]  H. Happ Power system control and stability , 1979, Proceedings of the IEEE.

[19]  Mehrdad Ghandhari,et al.  Improving power system dynamics by series-connected FACTS devices , 1997 .

[20]  Peter W. Sauer,et al.  Power System Dynamics and Stability , 1997 .