Elastic surface contour detection for the measurement of ejection fraction in myocardial perfusion SPET

Abstract. The aim of this study was to investigate the use of an automated three-dimensional myocardial contour detection method using elastic surfaces for the assessment of left ventricular ejection fraction (EF) from electrocardiographically (ECG) triggered myocardial perfusion single-photon emission tomography (SPET). The validity of this method was studied on the basis of both phantom measurements and patient studies. Phantom measurements were performed using an elastic phantom of the left ventricle simulating a beating heart, with a simulated EF ranging from 10% to 78%. The data from 27 patients who had undergone both ECG-triggered myocardial perfusion SPET and planar gated radionuclide ventriculography (RNV) were used to compare the EF derived from the SPET data with the automated contour detection method and the EF derived from the RNV data with standard analysis software. EF values as measured by RNV ranged from 11% to 68%. The overall accuracy of the automated contour detection method proved to be very high. In the phantom study the deviation of the measured EF from the reference values was less than 4% for all of the simulated EFs. The studies on the patient data yielded a correlation coefficient (Pearson) greater than 0.94 as compared with planar RNV. Intra- and inter-observer reproducibility was high, with correlation coefficients exceeding 0.97. It is concluded that the proposed method allows accurate, reproducible and fast measurement of the left ventricular EF on the basis of myocardial perfusion SPET.

[1]  K. Hammermeister,et al.  Variables Predictive of Survival in Patients with Coronary Disease: Selection by Univariate and Multivariate Analyses from the Clinical, Electrocardiographic, Exercise, Arteriographic, and Quantitative Angiographic Evaluations , 1979 .

[2]  J M Bacos,et al.  The usefulness of radionuclide ventriculography for the identification and assessment of patients with coronary heart disease. , 1980, American heart journal.

[3]  G Germano,et al.  Automatic reorientation of three-dimensional, transaxial myocardial perfusion SPECT images. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[5]  C. Cooke,et al.  Three-dimensional display of cardiac single photon emission computed tomography. , 1993, American journal of cardiac imaging.

[6]  A. DeMaria,et al.  Recommendations Regarding Quantitation in M-Mode Echocardiography: Results of a Survey of Echocardiographic Measurements , 1978, Circulation.

[7]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[8]  T. Faber,et al.  Three-dimensional motion and perfusion quantification in gated single-photon emission computed tomograms. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  D. L. Johnston,et al.  Determination of ventricular ejection fraction: a comparison of available imaging methods. The Cardiovascular Imaging Working Group. , 1997, Mayo Clinic proceedings.

[10]  Torsten Kuwert,et al.  Three-dimensional contour detection of left ventricular myocardium using elastic surfaces , 1999, European Journal of Nuclear Medicine.

[11]  W Grossman,et al.  Estimation of left ventricular volumes in man from biplane cineangiograms filmed in oblique projections. , 1978, The American journal of cardiology.

[12]  J. Sau,et al.  Automated detection of the left ventricular region in gated nuclear cardiac imaging , 1996, IEEE Transactions on Biomedical Engineering.

[13]  R R Miller,et al.  A New, Simplified and Accurate Method for Determining Ejection Fraction with Two‐dimensional Echocardiography , 1981, Circulation.

[14]  T. Brady,et al.  Exercise radionuclide ejection fraction: correlation with exercise contrast ventriculography. , 1979, Radiology.

[15]  E. Hoffman,et al.  Quantitation in Positron Emission Computed Tomography: 1. Effect of Object Size , 1979, Journal of computer assisted tomography.

[16]  P. Hugenholtz,et al.  The In Vivo Determination of Left Ventricular Volume: Comparison of the Fiberoptic‐Indicator Dilution and the Angiocardiographic Methods , 1968, Circulation.

[17]  R. Railton,et al.  Inter-observer variation in estimates by nuclear angiography of left ventricular ejection fraction and ejection rate. , 1980, The British journal of radiology.

[18]  J A Parker,et al.  Radionuclide left ventriculography with the slant hole collimator. , 1977, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  T. Gjørup,et al.  Reproducibility in the analysis of multigated radionuclide studies of left ventricular ejection fraction. , 1989, Investigative radiology.

[20]  E G DePuey,et al.  Left ventricular ejection fraction assessed from gated technetium-99m-sestamibi SPECT. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[21]  R. Pettigrew,et al.  Three-dimensional displays of left ventricular epicardial surface from standard cardiac SPECT perfusion quantification techniques. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[22]  D. Berman,et al.  Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[23]  H Sandler,et al.  The use of single plane angiocardiograms for the calculation of left ventricular volume in man. , 1968, American heart journal.

[24]  Kuang-Tao A. Yang,et al.  Evaluation of global and regional left ventricular function using technetium-99m sestamibi ECG-gated single-photon emission tomography , 1998, European Journal of Nuclear Medicine.