Novel BOD optical fiber biosensor based on co-immobilized microorganisms in ormosils matrix.

A biochemical oxygen demand (BOD) sensor has been developed, which is based on an immobilized mixed culture of microorganisms combined with a dissolved oxygen (DO) optical fiber. The sensing film for BOD measurement consists of an organically-modified silicate (ORMOSIL) film embedded with tri(4,7-diphenyl-1,10-phenanthroline) ruthenium(II) perchlorate and three kinds of seawater microorganisms immobilized on a polyvinyl alcohol sol-gel matrix. The BOD measurements were carried out in the kinetic mode inside a light-proof cell and with constant temperature. Measurements were taken for 3 min followed by 10 min recovery time in 10 mg/L glucose/glutamate (GGA) BOD standard solution, and the range of determination was from 0.2 to 40 mg/L GGA. The effects of temperature, pH and sodium chloride concentration on the BOD sensing films were studied. BOD values estimated by this optical BOD sensing film correlate well with those determined by the conventional BOD5 method for seawater samples.

[1]  Jae Kyung Jang,et al.  A microbial fuel cell with improved cathode reaction as a low biochemical oxygen demand sensor , 2003, Biotechnology Letters.

[2]  R. Renneberg,et al.  Arxula adeninivorans Based Sensor for the Estimation of BOD , 1998 .

[3]  A. Walcarius Electroanalysis with Pure, Chemically Modified and Sol-Gel-Derived Silica-Based Materials , 2001 .

[4]  E. Tamiya,et al.  An organic pollution sensor based on surface photovoltage , 1998 .

[5]  H. Schmidt Organic modification of glass structure new glasses or new polymers , 1989 .

[6]  Kwok-Yin Wong,et al.  The performance of oxygen sensing films with ruthenium-adsorbed fumed silica dispersed in silicone rubber , 1999 .

[7]  R. Renneberg,et al.  Measurement of biodegradable substances with a mycelia-sensor based on the salt tolerant yeast Arxula adeninivorans LS3 , 2000 .

[8]  C. Brinker Sol-gel science , 1990 .

[9]  Jae Kyung Jang,et al.  Continuous determination of biochemical oxygen demand using microbial fuel cell type biosensor. , 2004, Biosensors & bioelectronics.

[10]  Shaojun Dong,et al.  Co-immobilized microbial biosensor for BOD estimation based on sol-gel derived composite material. , 2003, Biosensors & bioelectronics.

[11]  Ingo Klimant,et al.  Oxygen-Sensitive Luminescent Materials Based on Silicone-Soluble Ruthenium Diimine Complexes , 1995 .

[12]  K. Asai,et al.  Fluorescence quenching oxygen sensor using an aluminum phthalocyanine–polystyrene film , 2000 .

[13]  Baohong Liu,et al.  A BOD biosensor based on a microorganism immobilized on an Al2O3 sol–gel matrix , 2002, Analytical and bioanalytical chemistry.

[14]  I Karube,et al.  Optical fiber biosensor for the determination of low biochemical oxygen demand. , 2000, Biosensors & bioelectronics.

[15]  Ingo Klimant,et al.  Optical Fiber Sensor for Biological Oxygen Demand , 1994 .

[16]  Shigeru Maeda,et al.  A Bod Sensor Using Klebsiella Oxytoca AS1 , 1994 .

[17]  Isao Karube,et al.  Biosensor for the estimation of low biochemical oxygen demand , 1999 .

[18]  Frieder W. Scheller,et al.  A fast estimation of biochemical oxygen demand using microbial sensors , 1988, Applied Microbiology and Biotechnology.

[19]  I Karube,et al.  Microbial electrode BOD sensors , 1977, Biotechnology and bioengineering.

[20]  蒋亚琪,et al.  Luminescence quenching behavior of oxygen sensing ORMOSIL films based on ruthenium complex , 2001 .

[21]  B Mattiasson,et al.  Immobilised activated sludge based biosensor for biochemical oxygen demand measurement. , 2000, Biosensors & bioelectronics.

[22]  Shikha Rastogi,et al.  Development and characterization of a novel immobilized microbial membrane for rapid determination of biochemical oxygen demand load in industrial waste-waters. , 2003, Biosensors & bioelectronics.

[23]  R. Renneberg,et al.  Designing an amperometric thick-film microbial BOD sensor. , 2000, Biosensors & bioelectronics.

[24]  K. Neoh,et al.  Measurement of BOD by initial rate of response of a microbial sensor , 1993 .

[25]  Xiao-ru Wang,et al.  Fluorescent response of sol-gel derived ormosils for optical ammonia sensing film , 2004 .

[26]  Z. Qian,et al.  RESPONSE CHARACTERISTICS OF A DEAD-CELL BOD SENSOR , 1998 .

[27]  Koji Nakane,et al.  Properties and structure of poly(vinyl alcohol)/silica composites , 1999 .

[28]  Kwok-Yin Wong,et al.  Comparison of BOD optical fiber biosensors based on different microorganisms immobilized in ormosil matrixes , 2004 .

[29]  Paul Hartmann,et al.  Photobleaching of a ruthenium complex in polymers used for oxygen optodes and its inhibition by singlet oxygen quenchers , 1998 .

[30]  A. König,et al.  Multimicrobial sensor using microstructured three-dimensional electrodes based on silicon technology. , 2000, Analytical chemistry.

[31]  R. Renneberg,et al.  Measurement of biodegradable substances using the salt-tolerant yeast Arxula adeninivorans for a microbial sensor immobilized with poly(carbamoyl)sulfonate (PCS). Part II: Application of the novel biosensor to real samples from coastal and island regions. , 1999, Biosensors & bioelectronics.