Few-view cone-beam CT reconstruction with deformed prior image.

PURPOSE Prior images can be incorporated into the image reconstruction process to improve the quality of subsequent cone-beam CT (CBCT) images from sparse-view or low-dose projections. The purpose of this work is to develop a deformed prior image-based reconstruction (DPIR) strategy to mitigate the deformation between the prior image and the target image. METHODS The deformed prior image is obtained by a projection-based registration approach. Specifically, the deformation vector fields used to deform the prior image are estimated through iteratively matching the forward projection of the deformed prior image and the measured on-treatment projections. The deformed prior image is then used as the prior image in the standard prior image constrained compressed sensing (PICCS) algorithm. A simulation study on an XCAT phantom and a clinical study on a head-and-neck cancer patient were conducted to evaluate the performance of the proposed DPIR strategy. RESULTS The deformed prior image matches the geometry of the on-treatment CBCT more closely as compared to the original prior image. Consequently, the performance of the DPIR strategy from few-view projections is improved in comparison to the standard PICCS algorithm, based on both visual inspection and quantitative measures. In the XCAT phantom study using 20 projections, the average root mean squared error is reduced from 14% in PICCS to 10% in DPIR, and the average universal quality index increases from 0.88 in PICCS to 0.92 in DPIR. CONCLUSIONS The present DPIR approach provides a practical solution to the mismatch problem between the prior image and target image, which improves the performance of the original PICCS algorithm for CBCT reconstruction from few-view or low-dose projections.

[1]  Lei Xing,et al.  Cone beam CT imaging with limited angle of projections and prior knowledge for volumetric verification of non-coplanar beam radiation therapy: a proof of concept study. , 2013, Physics in medicine and biology.

[2]  Fang-Fang Yin,et al.  Radiation dose from cone beam CT in a pediatric phantom: risk estimation of cancer incidence. , 2010, AJR. American journal of roentgenology.

[3]  A. Katsevich Analysis of an exact inversion algorithm for spiral cone-beam CT. , 2002, Physics in medicine and biology.

[4]  Charles W. Coffey,et al.  Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. , 2009, International journal of radiation oncology, biology, physics.

[5]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[6]  Xuejun Gu,et al.  Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[7]  Lei Zhang,et al.  Low-Dose X-ray CT Reconstruction via Dictionary Learning , 2012, IEEE Transactions on Medical Imaging.

[8]  J H Siewerdsen,et al.  Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype. , 2006, Medical physics.

[9]  Lei Xing,et al.  Improved compressed sensing-based cone-beam CT reconstruction using adaptive prior image constraints , 2012, Physics in medicine and biology.

[10]  Xiaochuan Pan,et al.  Accurate image reconstruction in circular cone-beam computed tomography by total variation minimization: a preliminary investigation , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[11]  Jie Tang,et al.  Low radiation dose C-arm cone-beam CT based on prior image constrained compressed sensing (PICCS): including compensation for image volume mismatch between multiple data acquisitions , 2009, Medical Imaging.

[12]  Steve B. Jiang,et al.  Low-dose CT reconstruction via edge-preserving total variation regularization , 2010, Physics in medicine and biology.

[13]  Timothy D. Solberg,et al.  Noise reduction in low-dose cone beam CT by incorporating prior volumetric image information , 2013 .

[14]  T. Mackie,et al.  Fast free-form deformable registration via calculus of variations , 2004, Physics in medicine and biology.

[15]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.

[16]  Guang-Hong Chen,et al.  Performance studies of four-dimensional cone beam computed tomography , 2011, Physics in medicine and biology.

[17]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[18]  L. Xing,et al.  Overview of image-guided radiation therapy. , 2006, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[19]  Jie Tang,et al.  Prior image constrained compressed sensing: implementation and performance evaluation. , 2011, Medical physics.

[20]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[21]  Emmanuel J. Candès,et al.  Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information , 2004, IEEE Transactions on Information Theory.

[22]  Jing Huang,et al.  Iterative Reconstruction for X-Ray Computed Tomography Using Prior-Image Induced Nonlocal Regularization , 2014, IEEE Transactions on Biomedical Engineering.

[23]  Jie Tang,et al.  Time-resolved cardiac interventional cone-beam CT reconstruction from fully truncated projections using the prior image constrained compressed sensing (PICCS) algorithm , 2012, Physics in medicine and biology.

[24]  Jing Wang,et al.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography , 2006, IEEE Transactions on Medical Imaging.

[25]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[26]  A. Bovik,et al.  A universal image quality index , 2002, IEEE Signal Processing Letters.

[27]  Xiaochuan Pan,et al.  Few-view and limited-angle cone-beam megavoltage CT for breast localization in radiation therapy , 2004, SPIE Medical Imaging.

[28]  Guang-Hong Chen,et al.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study. , 2011, Medical physics.

[29]  Jie Tang,et al.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. , 2008, Medical physics.

[30]  Jing Wang,et al.  High-quality four-dimensional cone-beam CT by deforming prior images. , 2013, Physics in medicine and biology.

[31]  Guang-Hong Chen,et al.  Perfusion measurements by micro-CT using prior image constrained compressed sensing (PICCS): initial phantom results , 2010, Physics in medicine and biology.

[32]  Guang-Hong Chen,et al.  Time-Resolved Interventional Cardiac C-arm Cone-Beam CT: An Application of the PICCS Algorithm , 2012, IEEE Transactions on Medical Imaging.

[33]  G. Herman,et al.  Algebraic reconstruction techniques (ART) for three-dimensional electron microscopy and x-ray photography. , 1970, Journal of theoretical biology.

[34]  Steve B. Jiang,et al.  Low-dose CT reconstruction via edge-preserving total variation regularization. , 2010, Physics in medicine and biology.

[35]  W. Segars,et al.  4D XCAT phantom for multimodality imaging research. , 2010, Medical physics.

[36]  Qianjin Feng,et al.  Low-dose computed tomography image restoration using previous normal-dose scan. , 2011, Medical physics.

[37]  M. V. van Herk,et al.  Respiratory correlated cone beam CT. , 2005, Medical physics.