Development of a Regenerative Peripheral Nerve Interface for Control of a Neuroprosthetic Limb

Background. The purpose of this experiment was to develop a peripheral nerve interface using cultured myoblasts within a scaffold to provide a biologically stable interface while providing signal amplification for neuroprosthetic control and preventing neuroma formation. Methods. A Regenerative Peripheral Nerve Interface (RPNI) composed of a scaffold and cultured myoblasts was implanted on the end of a divided peroneal nerve in rats (n = 25). The scaffold material consisted of either silicone mesh, acellular muscle, or acellular muscle with chemically polymerized poly(3,4-ethylenedioxythiophene) conductive polymer. Average implantation time was 93 days. Electrophysiological tests were performed at endpoint to determine RPNI viability and ability to transduce neural signals. Tissue samples were examined using both light microscopy and immunohistochemistry. Results. All implanted RPNIs, regardless of scaffold type, remained viable and displayed robust vascularity. Electromyographic activity and stimulated compound muscle action potentials were successfully recorded from all RPNIs. Physiologic efferent motor action potentials were detected from RPNIs in response to sensory foot stimulation. Histology and transmission electron microscopy revealed mature muscle fibers, axonal regeneration without neuroma formation, neovascularization, and synaptogenesis. Desmin staining confirmed the preservation and maturation of myoblasts within the RPNIs. Conclusions. RPNI demonstrates significant myoblast maturation, innervation, and vascularization without neuroma formation.

[1]  R. Midha,et al.  Traumatic neuroma in continuity injury model in rodents. , 2012, Journal of neurotrauma.

[2]  D. Kipke,et al.  Cytotoxic analysis of the conducting polymer PEDOT using myocytes , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  Tae Jin Kang,et al.  Preparation and Properties of Electrically Conducting Textiles by In Situ Polymerization of Poly(3,4- ethylenedioxythiophene) , 2005 .

[4]  In Vivo Electrical Conductivity across Critical Nerve Gaps Using Poly(3,4-ethylenedioxythiophene)-Coated Neural Interfaces , 2010, Plastic and reconstructive surgery.

[5]  S. Mackinnon,et al.  Treatment of the Painful Neuroma by Neuroma Resection and Muscle Implantation , 1986, Plastic and reconstructive surgery.

[6]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[7]  E. Modirian,et al.  Neuroma in bilateral upper limb amputation. , 2008, Orthopedics.

[8]  J. Faulkner,et al.  Functional development of engineered skeletal muscle from adult and neonatal rats. , 2001, Tissue engineering.

[9]  Lloyd H. Michael,et al.  The Guide for the Care and Use of Laboratory Animals. , 2016, ILAR journal.

[10]  T. Kuiken Targeted reinnervation for improved prosthetic function. , 2006, Physical Medicine and Rehabilitation Clinics of North America.

[11]  Miss A.O. Penney (b) , 1974, The New Yale Book of Quotations.

[12]  David C. Martin,et al.  In situ polymerization of a conductive polymer in acellular muscle tissue constructs. , 2008, Tissue engineering. Part A.

[13]  D. Kipke,et al.  Conduction Properties Of Decellularized Nerve Biomaterials. , 2010, IFMBE proceedings.

[14]  Robert D. Lipschutz,et al.  Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms. , 2009, JAMA.

[15]  Kevin J. Otto,et al.  In vivo polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT) in rodent cerebral cortex , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[16]  T. Kuiken,et al.  The effects of targeted muscle reinnervation on neuromas in a rabbit rectus abdominis flap model. , 2012, The Journal of hand surgery.

[17]  D. Elliot,et al.  The surgical management of painful nerves of the upper limb: a unit perspective , 2011, The Journal of hand surgery, European volume.

[18]  A. Pestronk,et al.  A new stain for quantitative measurement of sprouting at neuromuscular junctions , 1978, Muscle & nerve.

[19]  H von Holst,et al.  Toxicity evaluation of PEDOT/biomolecular composites intended for neural communication electrodes , 2009, Biomedical materials.

[20]  T. Kuiken,et al.  Neural Interfaces for Control of Upper Limb Prostheses: The State of the Art and Future Possibilities , 2011, PM & R : the journal of injury, function, and rehabilitation.

[21]  David C. Martin,et al.  Polymerization of the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) around living neural cells. , 2007, Biomaterials.

[22]  Silvestro Micera,et al.  A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems , 2005, Journal of the peripheral nervous system : JPNS.

[23]  Michael D Joseph,et al.  Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes , 2011, Journal of neural engineering.