Fabrication and characterization of SU-8-based capacitive micromachined ultrasonic transducer for airborne applications

Abstract. We present a successful fabrication and characterization of a capacitive micromachined ultrasonic transducer (CMUT) with SU-8 as the membrane material. The goal of this research is to develop a post-CMOS compatible CMUT that can be monolithically integrated with the CMOS circuitry. The fabrication is based on a simple, three mask process, with all wet etching steps involved so that the device can be realized with minimal laboratory conditions. The maximum temperature involved in the whole process flow was 140°C, and hence, it is post-CMOS compatible. The fabricated device exhibited a resonant frequency of 835 kHz with bandwidth 62 kHz, when characterized in air. The pull-in and snapback characteristics of the device were analyzed. The influence of membrane radius on the center frequency and bandwidth was also experimentally evaluated by fabricating CMUTs with membrane radius varying from 30 to 54  μm with an interval of 4  μm. These devices were vibrating at frequencies from 5.2 to 1.8 MHz with an average Q-factor of 23.41. Acoustic characterization of the fabricated devices was performed in air, demonstrating the applicability of SU-8 CMUTs in airborne applications.

[1]  D. Schindel,et al.  The use of broadband acoustic transducers and pulse-compression techniques for air-coupled ultrasonic imaging. , 2001, Ultrasonics.

[2]  E. Ventsel,et al.  Thin Plates and Shells: Theory: Analysis, and Applications , 2001 .

[3]  Rudra Pratap,et al.  Elasto-Electrostatic Analysis of Circular Microplates Used in Capacitive Micromachined Ultrasonic Transducers , 2010, IEEE Sensors Journal.

[4]  A. Fenster,et al.  3-D ultrasound imaging: a review , 1996 .

[5]  J. Yeow,et al.  Fabrication of capacitive micromachined ultrasonic transducers based on adhesive wafer bonding technique , 2016 .

[6]  Butrus T. Khuri-Yakub,et al.  The microfabrication of capacitive ultrasonic transducers , 1998 .

[7]  D. Schindel,et al.  Air-coupled ultrasonic NDE of bonded aluminum lap joints , 1997 .

[8]  Robert C. White,et al.  Releasing SU-8 structures using polystyrene as a sacrificial material , 2004 .

[9]  O. Oralkan,et al.  A Low-Noise Oscillator based on a Multi-Membrane CMUT for High Sensitivity Resonant Chemical Sensors , 2009, 2009 IEEE 22nd International Conference on Micro Electro Mechanical Systems.

[10]  Kwan Kyu Park,et al.  Capacitive micromachined ultrasonic transducers for chemical detection in nitrogen , 2007 .

[11]  Xuefeng Zhuang,et al.  Capacitive micromachined ultrasonic transducers (CMUTs) with isolation posts , 2004, IEEE Ultrasonics Symposium, 2004.

[12]  N. Spencer,et al.  Tailoring SU-8 surfaces: covalent attachment of polymers by means of nitrene insertion. , 2014, Langmuir : the ACS journal of surfaces and colloids.

[13]  Shiv Govind Singh,et al.  Fabrication of SU-8 based Capacitive Micromachined Ultrasonic Transducer for low frequency therapeutic applications , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[14]  Butrus T. Khuri-Yakub,et al.  Capacitive Micromachined Ultrasonic Transducers: Theory and Technology , 2003 .

[15]  Abdullah Atalar,et al.  Bandwidth, power and noise considerations in airborne cMUTs , 2009, 2009 IEEE International Ultrasonics Symposium.

[16]  Deleep R. Nair,et al.  Study of the Effect of Surface Roughness on the Performance of RF MEMS Capacitive Switches Through 3-D Geometric Modeling , 2016, IEEE Journal of the Electron Devices Society.

[17]  Qiongfeng Shi,et al.  MEMS Based Broadband Piezoelectric Ultrasonic Energy Harvester (PUEH) for Enabling Self-Powered Implantable Biomedical Devices , 2016, Scientific Reports.

[18]  I. Ladabaum,et al.  The microfabrication of capacitive ultrasonic transducers , 1997, Proceedings of International Solid State Sensors and Actuators Conference (Transducers '97).

[19]  Registration of surface structures using airborne focused ultrasound. , 1991, Ultrasound in medicine & biology.

[20]  M. Despont,et al.  SU-8: a low-cost negative resist for MEMS , 1997 .

[21]  P. Hasler,et al.  Front-end CMOS electronics for monolithic integration with CMUT arrays: Circuit design and initial experimental results , 2008, 2008 IEEE Ultrasonics Symposium.

[22]  Yipeng Lu,et al.  Modeling, Fabrication, and Characterization of Piezoelectric Micromachined Ultrasonic Transducer Arrays Based on Cavity SOI Wafers , 2015, Journal of Microelectromechanical Systems.

[23]  O. Oralkan,et al.  Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  R. Kodzius,et al.  Resonant gravimetric immunosensing based on capacitive micromachined ultrasound transducers , 2014, Microchimica Acta.

[26]  D. Hutchins,et al.  The use of air-coupled ultrasound to test paper , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  O. Oralkan,et al.  6D-1 The Capacitive Micromachined Ultrasonic Transducer (CMUT) as a Chem/Bio Sensor , 2007, 2007 IEEE Ultrasonics Symposium Proceedings.

[28]  B. Khuri-Yakub,et al.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging? , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[29]  Edward Hæggström,et al.  Fabricating capacitive micromachined ultrasonic transducers with wafer-bonding technology , 2003 .

[30]  Shiv Govind Singh,et al.  A low pull-in SU-8 based Capacitive Micromachined Ultrasonic Transducer for medical imaging applications , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[31]  A. Boisen,et al.  Functionalization of SU-8 photoresist surfaces with IgG proteins , 2008 .

[32]  O. Oralkan,et al.  Wafer-bonded 2-D CMUT arrays incorporating through-wafer trench-isolated interconnects with a supporting frame , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[33]  Omer Oralkan,et al.  Fabrication of anodically bonded capacitive micromachined ultrasonic transducers with vacuum-sealed cavities , 2014, 2014 IEEE International Ultrasonics Symposium.

[34]  Nam-Trung Nguyen,et al.  SU‐8 as a structural material for labs‐on‐chips and microelectromechanical systems , 2007, Electrophoresis.

[35]  Jack W. Judy,et al.  Micromachined polymer-based chemical gas sensor array , 2001 .

[36]  Chengkuo Lee,et al.  Zero-Bending Piezoelectric Micromachined Ultrasonic Transducer (pMUT) With Enhanced Transmitting Performance , 2015, Journal of Microelectromechanical Systems.

[37]  Sujeet K. Sinha,et al.  Releasing high aspect ratio SU-8 microstructures using AZ photoresist as a sacrificial layer on metallized Si substrates , 2013 .

[38]  I. Ladabaum,et al.  Theory and analysis of electrode size optimization for capacitive microfabricated ultrasonic transducers , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[39]  Bozena Kaminska,et al.  PDMS as a sacrificial substrate for SU-8-based biomedical and microfluidic applications , 2008 .

[40]  M. Kupnik,et al.  CMUTs for air coupled ultrasound with improved bandwidth , 2011, 2011 IEEE International Ultrasonics Symposium.

[41]  Rudra Pratap,et al.  Coupled nonlinear effects of surface roughness and rarefaction on squeeze film damping in MEMS structures , 2004 .

[42]  Gailius Vanagas,et al.  Capacitive micromachined ultrasound transducer (cMUT) for immunosensor design. , 2010, The Analyst.

[43]  G. Palasantzas Self-affine roughness influence on the pull-in voltage in capacitive electromechanical devices , 2005 .

[44]  J. D. Fox,et al.  Acoustic microscopy in air at 2 MHz , 1985 .

[45]  Peter Vettiger,et al.  High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS , 1998 .

[46]  Kwan Kyu Park,et al.  Capacitive micromachined ultrasonic transducer as a chemical sensor , 2008, 2008 IEEE Sensors.

[47]  Laura M. Lechuga,et al.  Polymeric cantilever arrays for biosensing applications , 2003 .

[48]  Jeong-Bong (JB) Lee,et al.  A SU-8-Based Microfabricated Implantable Inductively Coupled Passive RF Wireless Intraocular Pressure Sensor , 2012, Journal of Microelectromechanical Systems.

[49]  Wanjun Wang,et al.  A quantitative study on the adhesion property of cured SU-8 on various metallic surfaces , 2005 .

[50]  Confocal scanning acoustic air microscope with phase contrast , 1998 .

[51]  Anja Boisen,et al.  SU-8 cantilever sensor system with integrated readout , 2005 .

[52]  O. Oralkan,et al.  A low-power gas sensor for environmental monitoring using a capacitive micromachined ultrasonic transducer , 2014, IEEE SENSORS 2014 Proceedings.