A Novel Analog Front End with Voltage-Dependent Input Impedance and Bandpass Amplification for Capacitive Biopotential Measurements

This paper proposes a novel analogue front end (AFE) that has three features: voltage-dependent input impedance, bandpass amplification, and stray capacitance reduction. With a view to applying the AFE to capacitive biopotential measurements (CBMs), the three features were investigated separately in a schematic and mathematical manner. Capacitive electrocardiogram (cECG) or capacitive electromyogram (cEMG) measurements using the AFE were performed in low-humidity conditions (below 35% relative humidity) for a total of seven human subjects. Performance evaluation of the AFE revealed the following: (1) the proposed AFE in cECG measurement with 1.70-mm thick clothing reduced the baseline recovery time and root mean square voltage of respiratory interference in subjects with healthy-weight body mass index (BMI), and increased R-wave amplitude for overweight-BMI subjects; and (2) the proposed AFE in cEMG measurement of biceps brachii muscle yielded stable electromyographic waveforms without the marked DC component for all subjects and a significant (p < 0.01) increase in the signal-to-noise ratio. These results indicate that the proposed AFE can provide a feasible balance between sensitivity and stability in CBMs, and it could be a versatile replacement for the conventional voltage follower used in CBMs.

[1]  Akinori Ueno,et al.  Design and Validation of Front-End Voltage Follower for Capacitive Electrocardiogram Measurement Using Bootstrapping Technique , 2018, 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[2]  Geert Langereis,et al.  Contactless EMG sensors embroidered onto textile , 2007, BSN.

[3]  Rita Paradiso,et al.  A wearable health care system based on knitted integrated sensors , 2005, IEEE Transactions on Information Technology in Biomedicine.

[4]  Enzo Pasquale Scilingo,et al.  Performance evaluation of sensing fabrics for monitoring physiological and biomechanical variables , 2005, IEEE Transactions on Information Technology in Biomedicine.

[5]  S. Leonhardt,et al.  Non-contact ECG monitoring for automotive application , 2008, 2008 5th International Summer School and Symposium on Medical Devices and Biosensors.

[6]  V. C. Padaki,et al.  Smart Vest: wearable multi-parameter remote physiological monitoring system. , 2008, Medical engineering & physics.

[7]  Koichi Matsuda,et al.  Spectral-Distance-Based Detection of EMG Activity From Capacitive Measurements , 2018, IEEE Sensors Journal.

[8]  Steffen Leonhardt,et al.  Wireless and Non-contact ECG Measurement System – the “Aachen SmartChair” , 2007 .

[9]  Akinori Ueno,et al.  An Application of Capacitive Electrode for Detecting Electrocardiogram of Neonates and Infants , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  Tolga Soyata,et al.  Toward Uniform Smart Healthcare Ecosystems: A Survey on Prospects, Security, and Privacy Considerations , 2019, Connected Health in Smart Cities.

[11]  Steffen Leonhardt,et al.  ECG on the Road: Robust and Unobtrusive Estimation of Heart Rate , 2011, IEEE Transactions on Biomedical Engineering.

[12]  Carmen C. Y. Poon,et al.  M-Health: The Development of Cuff-less and Wearable Blood Pressure Meters for Use in Body Sensor Networks , 2006, 2006 IEEE/NLM Life Science Systems and Applications Workshop.

[13]  Gert Cauwenberghs,et al.  Ultra-High Input Impedance, Low Noise Integrated Amplifier for Noncontact Biopotential Sensing , 2011, IEEE Journal on Emerging and Selected Topics in Circuits and Systems.

[14]  M Esashi,et al.  A barium-titanate-ceramics capacitive-type EEG electrode. , 1973, IEEE transactions on bio-medical engineering.

[15]  Michael Friedrich Russold,et al.  Capacitive Sensing of Surface EMG for Upper Limb Prostheses Control , 2016 .

[16]  P. C. Richardson,et al.  Capacitive electrocardiographic and bioelectric electrodes. , 1969, IEEE transactions on bio-medical engineering.

[17]  Farhaan Mirza,et al.  A Systematic Review of Wearable Sensors and IoT-Based Monitoring Applications for Older Adults – a Focus on Ageing Population and Independent Living , 2019, Journal of Medical Systems.

[18]  Steffen Leonhardt,et al.  On the way to a cable free operating theater: An operating table with integrated multimodal monitoring , 2011, 2011 Computing in Cardiology.

[19]  C. Van Hoof,et al.  Body-Heat Powered Autonomous Pulse Oximeter , 2006, 2006 5th IEEE Conference on Sensors.

[20]  N. Taccini,et al.  Sensing Fabrics for Monitoring Physiological and Biomechanical Variables: E-textile solutions , 2006, 2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors.

[21]  Kwang Suk Park,et al.  Common mode noise cancellation for electrically non-contact ECG measurement system on a chair. , 2005, Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference.

[22]  T. Jung,et al.  Dry and Noncontact EEG Sensors for Mobile Brain–Computer Interfaces , 2012, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[23]  Akinori Ueno,et al.  Stability improvement and noise suppression in non-contact in-bed electrocardiogram measurement using laminated feedback electrode , 2017, 2017 IEEE Biomedical Circuits and Systems Conference (BioCAS).

[24]  Gerhard Tröster,et al.  Unobtrusive physiological monitoring in an airplane seat , 2009, Personal and Ubiquitous Computing.

[25]  Kyung-Sup Kwak,et al.  The Internet of Things for Health Care: A Comprehensive Survey , 2015, IEEE Access.

[26]  Nikolaos G. Bourbakis,et al.  A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis , 2010, IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews).

[27]  Makoto Noshiro,et al.  Feasibility of Capacitive Sensing of Surface Electromyographic Potential through Cloth , 2012 .

[28]  Zhibo Pang,et al.  Smart Homes for Elderly Healthcare—Recent Advances and Research Challenges , 2017, Sensors.

[29]  Carmen C. Y. Poon,et al.  A clip-free eyeglasses-based wearable monitoring device for measuring photoplethysmograhic signals , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[30]  Akinori Ueno,et al.  Multi-layered fabric electrode for movement artifact reduction in capacitive ECG measurement , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[31]  G. Cauwenberghs,et al.  Micropower non-contact EEG electrode with active common-mode noise suppression and input capacitance cancellation , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[32]  Hannu Tenhunen,et al.  Bio-Patch Design and Implementation Based on a Low-Power System-on-Chip and Paper-Based Inkjet Printing Technology , 2012, IEEE Transactions on Information Technology in Biomedicine.

[33]  Tzyy-Ping Jung,et al.  Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review , 2010, IEEE Reviews in Biomedical Engineering.

[34]  Paul Lukowicz,et al.  AMON: a wearable multiparameter medical monitoring and alert system , 2004, IEEE Transactions on Information Technology in Biomedicine.

[35]  Ko Keun Kim,et al.  The ECG measurement in the bathtub using the insulated electrodes , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[36]  Rosalind W. Picard,et al.  Motion-tolerant magnetic earring sensor and wireless earpiece for wearable photoplethysmography , 2010, IEEE Transactions on Information Technology in Biomedicine.

[37]  Akinori Ueno,et al.  Noncontact In-Bed Measurements of Physiological and Behavioral Signals Using an Integrated Fabric-Sheet Sensing Scheme , 2019, IEEE Journal of Biomedical and Health Informatics.

[38]  Steffen Leonhardt,et al.  Triboelectricity in Capacitive Biopotential Measurements , 2011, IEEE Transactions on Biomedical Engineering.

[39]  K. Park,et al.  The electrically noncontacting ECG measurement on the toilet seat using the capacitively-coupled insulated electrodes , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[40]  Nitish V. Thakor,et al.  Ground-Free ECG Recording with Two Electrodes , 1980, IEEE Transactions on Biomedical Engineering.

[41]  Phillip A. Laplante,et al.  The Internet of Things in Healthcare: Potential Applications and Challenges , 2016, IT Professional.

[42]  Yong Gyu Lim,et al.  Conductive Polymer Foam Surface Improves the Performance of a Capacitive EEG Electrode , 2012, IEEE Transactions on Biomedical Engineering.

[43]  Akinori Ueno,et al.  Non-Contact Simultaneous Measurements of Electrocardiogram and Respiratory Movements Using Capacitive Sheet Electrodes , 2017 .

[44]  Tsuyoshi Kato,et al.  Capacitive Sensing of Electrocardiographic Potential Through Cloth From the Dorsal Surface of the Body in a Supine Position: A Preliminary Study , 2007, IEEE Transactions on Biomedical Engineering.

[45]  Wei Huang,et al.  Smart healthcare: making medical care more intelligent , 2019, Global Health Journal.