Operating performance in cooling mode of a ground source heat pump of a nearly-zero energy building in the cold region of China

A hybrid ground source heat pump system is utilized to meet the energy demands of the first nearly-zero energy office building located in the cold region of China. The simulation result shows that the heating, cooling and lighting demands of the building could be reduced to 25 kWh/m2 yr with the utilization of high-performance envelopes and the hybrid renewable energy system. A ground loop consisting of two rectangular fields of 70 borehole heat exchangers is utilized together with the solar energy system to meet the building's energy demand. During the system commissioning phase, from 1 July to 15 August 2014, the inlet and outlet water temperatures of the heat pump unit and boreholes were collected and analysed. The coefficient of performance (COP) of the heat pump unit could reach 5.0 in cooling operation strategy, which satisfies the energy reduction requirement and meets the room temperature standard.

[1]  Egidijus Juodis,et al.  Simulation based complex energy assessment of office building fenestration , 2010 .

[2]  E. Caamaño-Martín,et al.  ‘State-of-the-art’ of building integrated photovoltaic products , 2013 .

[3]  Nima Mirkhani,et al.  A comprehensive feasibility study of applying solar energy to design a zero energy building for a typical home in Tehran , 2014 .

[4]  Mahjoub Elnimeiri,et al.  The effect of geometry factors on fenestration energy performance and energy savings in office buildings , 2013 .

[5]  Xuyong Li,et al.  Modeling and performance evaluation of shallow ground water heat pumps in Beijing plain, China , 2011 .

[6]  Hyung-Jo Jung,et al.  Optimization of building window system in Asian regions by analyzing solar heat gain and daylighting elements , 2013 .

[7]  Marc A. Rosen,et al.  Geothermal heat pump systems: Status review and comparison with other heating options , 2013 .

[8]  Hatice Sözer,et al.  Improving energy efficiency through the design of the building envelope , 2010 .

[9]  Aie World Energy Outlook 2011 , 2001 .

[10]  Paul Kenny,et al.  From net energy to zero energy buildings: Defining life cycle zero energy buildings (LC-ZEB) , 2010 .

[11]  Arild Gustavsen,et al.  Windows in the Buildings of Tomorrow; Energy Losers or Energy Gainers? , 2013 .

[12]  Ove Mørck,et al.  The EU CONCERTO project Class 1 - Demonstrating cost-effective low-energy buildings - Recent results with special focus on comparison of calculated and measured energy performance of Danish buildings , 2012 .

[13]  Ergo Pikas,et al.  Facade design principles for nearly zero energy buildings in a cold climate , 2013 .

[14]  William W. Braham,et al.  Re(De)fining Net Zero Energy: Renewable Emergy Balance in environmental building design , 2012 .

[15]  Jing Zhao,et al.  Optimum combinations of building envelop energy-saving technologies for office buildings in different climatic regions of China , 2013 .

[16]  Daniel Pahud,et al.  Geocooling potential of borehole heat exchangers' systems applied to low energy office buildings , 2012 .

[17]  Robert Fuller,et al.  Progress in ZEBs—A review of definitions, policies and construction activity , 2013 .

[18]  M. Thring World Energy Outlook , 1977 .

[19]  Risto Kosonen,et al.  REHVA proposal for uniformed national implementation of EPBD recast , 2011 .

[20]  Karsten Voss,et al.  Net zero energy buildings: A consistent definition framework , 2012 .

[21]  Paul Rowley,et al.  Towards low carbon homes – a simulation analysis of building-integrated air-source heat pump systems , 2012 .

[22]  Joseph Sarkis,et al.  Regional application of ground source heat pump in China: A case of Shenyang , 2013 .