T est ing and analysi ng innovative design of UHPFRC anchor blocks for post-tensioning tendons
暂无分享,去创建一个
Experimental validation of innovative design of anchor blocks for post-tensioning tendons was carried out. The tested specimens were made of UHPFRC, namely Ductal®-FM for 9 blocks and BSI® for 3 other blocks, and did not contain any passive reinforcement normally provided for confining concrete submitted to localized compression, and preventing bursting. They were dedicated to 4T15S, 7T15S and 12T15S pre-stressing units. Splitting in the middle of block sides, leading to sub-vertical cracks, appears as the dominant critical mechanism. Depending on lateral dimensions of UHPFRC around the reservation, and possible size effects concerning this zone submitted to intense tensile stresses, the maximum load has been obtained from 1,2 to 2,2 times the ultimate force of the tendons Fprg, with a typical scatter about ± 10 %. While refinements remain possible for optimizing the safety margin depending on project requirements, obtained results validate the innovative (reinforcement-free) design and typical dimensions of these UHPFRC anchor blocks. 2 EXPERIMENTAL PROGRAM
[1] M. Behloul,et al. Seonyu Ductal® Footbridge , 2004 .
[2] Ziad Hajar,et al. Construction of an Ultra High Performance Fibre Reinforced Concrete thin shell structure over the Millau Viaduct toll-gates , 2004 .
[3] François Toutlemonde,et al. Innovative Design of Ultra High-Performance Fiber Reinforced Concrete Ribbed Slab: Experimental Validation and Preliminary Detailed Analyses , 2005 .
[4] F. Toutlemonde,et al. Safety of VHSC structures under concentrated loading: experimental approach , 2004 .