The influence of different degrees of stiffness of fixation plates on experimental bone healing

In order to throw some light on the controversial issue of the optimal stiffness in fracture fixation, the effects on bone healing of rabbit tibial osteotomies fixed by plates with four different degrees of stiffness were studied. The least stiff plate was made of glass fiber‐reinforced epoxy; the other three were made of stainless steel. The median bending stiffness in vitro of tibial osteotomies fixed with the various plates were 13%, 17%, 61%, and 74%, related to the stifness of intact tibiae. Transverse midshaft unilateral tibial osteotomies were fixed by the various plates, and the animals were killed after 6 weeks. The amount of periosteal callus was inversely related to the stiffness of the plates. A marked trend toward decreased strength and stiffness occurred in tibiae where the most rigid plate was used, compared with the values of those with the less rigid plates. This indicates that the stress‐protecting effect of very stiff plates begins early in the healing period and is pronounced even at 6 weeks and that a steel plate of lower stiffness is more appropriate for bone healing. However, too flexible plates involve increased risk of redislocation and mechanical failure.

[1]  P Slätis,et al.  The healing of experimental fractures by compression osteosynthesis. I. Torsional strength. , 1979, Acta orthopaedica Scandinavica.

[2]  M. Yamagishi,et al.  The biomechanics of fracture healing. , 1955, The Journal of bone and joint surgery. American volume.

[3]  C L Davidson,et al.  Protection from stress in bone and its effects. Experiments with stainless steel and plastic plates in dogs. , 1976, The Journal of bone and joint surgery. British volume.

[4]  A. White,et al.  Comparison of cyclic loading versus constant compression in the treatment of long-bone fractures in rabbits. , 1981, The Journal of bone and joint surgery. American volume.

[5]  S. Woo,et al.  Less rigid internal fixation plates: Historical perspectives and new concepts , 1984, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[6]  J. Greiff Bone healing in rabbits after compression osteosynthesis: a comparative study between the radiological and histological findings. , 1979, Injury.

[7]  F. W. Rhinelander,et al.  Tibial blood supply in relation to fracture healing. , 1974, Clinical orthopaedics and related research.

[8]  S. Olerud,et al.  Fracture healing in compression osteosynthesis in the dog. , 1968, The Journal of bone and joint surgery. British volume.

[9]  B. Mckibbin,et al.  The biology of fracture healing in long bones. , 1978, The Journal of bone and joint surgery. British volume.

[10]  P. Benum,et al.  Mechanical effects of metal plate fixation. In vitro investigation on intact and osteotomized human and rabbit tibiae. , 1983, Acta orthopaedica Scandinavica.

[11]  T. Terjesen Plate fixation of tibial fractures in the rabbit. Correlation of bone strength with duration of fixation. , 1984, Acta orthopaedica Scandinavica.

[12]  H. Uhthoff,et al.  Bone structure changes in the dog under rigid internal fixation. , 1971, Clinical orthopaedics and related research.

[13]  H. Uhthoff,et al.  The effects of metal plates on post-traumatic remodelling and bone mass. , 1983, The Journal of bone and joint surgery. British volume.

[14]  L. Anderson Compression plate fixation and the effect of different types of internal fixation on fracture healing. , 1993, Instructional course lectures.

[15]  S. Woo,et al.  Principles of less rigid internal fixation with plates. , 1980, Canadian journal of surgery. Journal canadien de chirurgie.

[16]  T. Terjesen Bone healing after metal plate fixation and external fixation of the osteotomized rabbit tibia. , 1984, Acta orthopaedica Scandinavica.

[17]  P. Benum,et al.  The stress-protecting effect of metal plates on the intact rabbit tibia. , 1983, Acta orthopaedica Scandinavica.