Research on regulation performance evaluation of Automatic Generation Control in power plants and its application

Automatic Generation Control (AGC) system is an important component of the power system for frequency control. Regulation performance of the large capacity generating units in the control area is closely associated with the development of AGC system. Therefore, to meet the safety of AGC and the efficiency of the generating units the regulation quality of the generating units which play the roles of peak regulation, frequency modulation in power grid should be regularly tested. According to the analysis of the dynamic process of actual generating power tracking AGC load instructions, a calculation approach of AGC regulation performance indicators based on the operation historical data from the power plants is proposed in this paper. In consideration of the transmission delays of information, the differences of regulation performance indicators calculation between generating units and grid dispatching center are analyzed. On the research of “two rules” implemented widely in China, the transmission delay time of AGC load instructions, the minimum retention time of effective instructions and the unit response moment are defined to calculate the regulation performance indicators more accurately. The proposed algorithm is applied to kinds of generating units in north China grid. The coincidence of the results from the approach and the actual AGC performance indicators verifies the validity of the proposed algorithm. The application of the approach is helpful to improves security and economy of power plants and power grid.

[1]  Li Ping-kan The realization and developments in Automatic Generation Control technology , 2004 .

[2]  K. Tomsovic,et al.  Application of linear matrix inequalities for load frequency control with communication delays , 2004, IEEE Transactions on Power Systems.

[3]  T. Sasaki,et al.  Dynamic analysis of generation control performance standards , 2002, IEEE Power Engineering Society Summer Meeting,.

[4]  Khosrow Moslehi,et al.  Power System Control Centers: Past, Present, and Future , 2005, Proceedings of the IEEE.

[5]  Han Fukun,et al.  Compensation Strategies of AGC Regulation Performance in Plants Management and Assessment System , 2010 .

[6]  H. Bevrani,et al.  A control strategy for LFC design with communication delays , 2005, 2005 International Power Engineering Conference.

[7]  D.C.H. Prowse,et al.  Experience with joint AGC regulation , 1994 .

[8]  Muwaffaq I. Alomoush,et al.  Load frequency control and automatic generation control using fractional-order controllers , 2010 .

[9]  Chika O. Nwankpa,et al.  Towards the real time monitoring of AGC , 2000, Proceedings of the 33rd Annual Hawaii International Conference on System Sciences.

[10]  Mohammad Bagher Menhaj,et al.  Decentralized robust adaptive load frequency control using interactions estimation , 2003 .

[11]  Shimin Yi,et al.  A modern heuristic optimization method for AGC performance assessment at a power plant level , 2009 .

[12]  Takashi Hiyama,et al.  Robust decentralized PI based LFC design for time-delay power systems , 2008 .

[13]  Li Dong-ming QUANTITATIVE EVALUATION OF REGULATION EFFICIENCY OF GENERATING SETS WITH AGC AND STUDY ON THE COMDENSATION MODES , 2001 .

[14]  Yannis L. Karnavas,et al.  AGC for autonomous power system using combined intelligent techniques , 2002 .

[15]  K. R. Sudha,et al.  Fuzzy C-Means clustering for robust decentralized load frequency control of interconnected power system with Generation Rate Constraint , 2012 .

[16]  Jun-yong Liu,et al.  Dynamical optimal real-time AGC reserve dispatch strategy and unit selection for frequency regulation , 2009, 2009 International Conference on Sustainable Power Generation and Supply.

[17]  He Fei-yue Networked AGC Robust Controller Design in Consideration of Communication Delay , 2006 .

[18]  Han Fu-kun A SURVEY ON AUTOMATIC GENERATION CONTROL SYSTEM IN NORTH CHINA POWER GRID , 2005 .