Laser absorption diagnostic for measuring acetylene concentrations in shock tubes

Abstract A fixed-wavelength direct absorption laser diagnostic for high-temperature measurements of acetylene concentration was developed. The diagnostic, based on a tunable continuous wave distributed feedback diode laser, was optimized primarily for studying chemical kinetics behind reflected shock waves. The center wavelength (3335.55 cm −1 ) of the tunable diagnostic was typically set at the peak of the 3300 cm −1 absorption band of acetylene at high temperatures. The absorption spectrum of acetylene diluted in argon was characterized using scanned-wavelength direct absorption measurements from 1070 to 1720 K and 0.8 to 4.0 atm. Line fitting of the measured absorption spectra was not possible due to the large number of transitions overlapped by pressure broadening that contribute to the spectrum. Instead, empirical fits for the peak absorption coefficient and its corresponding wavelength as a function of temperature and pressure were generated. Furthermore, in order to allow for characterization of interference absorption in kinetic studies, empirical fits for the acetylene absorption coefficient in the region around the primary absorption feature were developed. Absorption coefficient measurements of propyne and 1-butyne, which may be the primary interference candidates, reveal that their absorption coefficients are constant in the wavelength range of interest, and are much smaller than those of acetylene. Therefore, the acetylene concentration in the presence of these interfering species can be inferred using two-color techniques. The utility of the acetylene diagnostic was demonstrated by measuring acetylene mole fraction time-histories during the pyrolysis of propene and 1-butene.

[1]  Ronald K. Hanson,et al.  Shock tube measurements of ignition delay times for the butanol isomers , 2012 .

[2]  Genny A. Pang,et al.  High-Temperature Measurements of the Rate Constants for Reactions of OH with a Series of Large Normal Alkanes: n-Pentane, n-Heptane, and n-Nonane , 2011 .

[3]  Stephen E. Stein,et al.  Detailed kinetic modeling of soot formation in shock-tube pyrolysis of acetylene , 1985 .

[4]  Ronald K. Hanson,et al.  Recent advances in shock tube/laser diagnostic methods for improved chemical kinetics measurements , 2009 .

[5]  D. Hurtmans,et al.  The ν3 Fundamental in C2H2 , 1993 .

[6]  Fabian Mauss,et al.  Detailed mass spectrometric and modeling study of isomeric butene flames , 2013 .

[7]  D. Jacquemart,et al.  The IR spectrum of 12C2H2 : Line intensity measurements in the 1.4μm region and update of the databases , 2009 .

[8]  Gang Li,et al.  The HITRAN 2008 molecular spectroscopic database , 2005 .

[9]  V. Malathy Devi,et al.  Tunable diode laser measurements of N2- and air-broadened halfwidths: lines in the (ν4+ν5)0 band of 12C2H2 near 7.4 μm , 1985 .

[10]  A. Fayt,et al.  Radiative model for emission spectroscopy from optically thick laboratory acetylene samples at high temperature , 2011 .

[11]  Laurence S. Rothman,et al.  The IR acetylene spectrum in HITRAN: update and new results , 2003 .

[12]  Ronald K. Hanson,et al.  Applications of quantitative laser sensors to kinetics, propulsion and practical energy systems , 2011 .

[13]  R. Hanson,et al.  Multi-species measurements in 1-butanol pyrolysis behind reflected shock waves , 2012 .

[14]  Francisco P. J. Valero,et al.  Measurements of nitrogen-broadened line widths of acetylene at low temperatures , 1983 .

[15]  R. Hanson,et al.  High-Temperature Thermal Decomposition of Isobutane and n-Butane Behind Shock Waves , 2004 .

[16]  M. Allen,et al.  Diode laser absorption sensors for gas-dynamic and combustion flows. , 1998, Measurement science & technology.

[17]  R. Hanson,et al.  Shock tube measurements of the rate constant for the reaction cyclohexene → ethylene + 1,3-butadiene , 2013 .

[18]  Volker Ebert,et al.  TDLAS-based in situ measurement of absolute acetylene concentrations in laminar 2D diffusion flames , 2009 .

[19]  Ronald K. Hanson,et al.  Scanned- and fixed-wavelength absorption diagnostics for combustion measurements using multiplexed diode lasers , 1996 .

[20]  Zachary R Quine,et al.  Acetylene measurement in flames by chirp-based quantum cascade laser spectrometry. , 2009, Applied optics.