Modeling for intra-body communication with bone effect

Intra-body communication (IBC) is a new, different “wireless” communication technique based on the human tissue. This short range “wireless” communication technology provides an alternative solution to wearable sensors, home health system, telemedicine and implanted devices. The development of the IBC enables the possibilities of providing less complexity and convenient communication methodologies for these devices. By regarding human tissue as communication channel, IBC making use of the conductivities properties of human tissue to send electrical signal from transmitter to receiver. In this paper, the authors proposed a new mathematical model for galvanic coupling type IBC based on a human limb. Starting from the electromagnetic theory, the authors treat human tissue as volume conductor, which is in analogous with the bioelectric phenomena analysis. In order to explain the mechanism of galvanic coupling type technique of IBC, applying the quasi-static approximation, the governing equation can be reduced to Laplace Equation. Finally, the analytical model is evaluated with on-body measurement for testing its performance. The comparison result shows that the developed mathematical model can provide good approximation for galvanic coupling type IBC on human limb under low operating frequencies.

[1]  Peng Un Mak,et al.  A preliminary two dimensional model for Intra-body Communication of Body Sensor Networks , 2008, 2008 International Conference on Intelligent Sensors, Sensor Networks and Information Processing.

[2]  Wolfgang Fichtner,et al.  An Attempt to Model the Human Body as a Communication Channel , 2007, IEEE Transactions on Biomedical Engineering.

[3]  C. Gabriel Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies. , 1996 .

[4]  Shuichi Shoji,et al.  A very low-power consumption wireless ECG monitoring system using body as a signal transmission medium , 1997, Proceedings of International Solid State Sensors and Actuators Conference (Transducers '97).

[5]  Marc Simon Wegmüller,et al.  Intra-body communication for biomedical sensor networks , 2007 .

[6]  Peng Un Mak,et al.  Preliminary Modeling for Intra-Body Communication , 2009 .

[7]  Thoams Guthrie Zimmerman Personal area networks (PAN) : near-field intra-body communication , 1995 .

[8]  Robert Plonsey,et al.  Volume Conductor Theory , 1999 .

[9]  N. Felber,et al.  Measurement System for the Characterization of the Human Body as a Communication Channel at Low Frequency , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[10]  D. B. Heppner,et al.  Considerations of quasi-stationarity in electrophysiological systems. , 1967, The Bulletin of mathematical biophysics.

[11]  Michael Oberle,et al.  Low power systems-on-chip for biomedical applications , 2002 .

[12]  M. Hull,et al.  A new technique for transmission of signals from implantable transducers , 1998, IEEE Transactions on Biomedical Engineering.

[13]  Thomas G. Zimmerman,et al.  : Near-field , 2022 .