Recent Advances in Ion-selective membrane electrodes for in situ environmental water analysis

Ion-selective membrane electrodes (ISEs) have become very attractive sensing platforms for environmental water analysis. This review mainly presents recent advances in polymeric-based ISEs relevant ...

[1]  Cecylia Wardak,et al.  Solid contact cadmium ion-selective electrode based on ionic liquid and carbon nanotubes , 2015 .

[2]  Eric Bakker,et al.  Solid contact potentiometric sensors for trace level measurements. , 2006, Analytical chemistry.

[3]  Ali Kemal Yetisen,et al.  Paper-based microfluidic point-of-care diagnostic devices. , 2013, Lab on a chip.

[4]  Robert H. Byrne,et al.  Determination of nanomolar levels of nutrients in seawater , 2014 .

[5]  G. Crespo,et al.  Direct ion speciation analysis with ion-selective membranes operated in a sequential potentiometric/time resolved chronopotentiometric sensing mode. , 2012, Analytical chemistry.

[6]  M. Kühl,et al.  A nitrite microsensor for profiling environmental biofilms , 1997, Applied and environmental microbiology.

[7]  Dermot Diamond Peer Reviewed: Internet-Scale Sensing , 2004 .

[8]  A. Ivaska,et al.  Solid-contact ion-selective electrodes with highly selective thioamide derivatives of p-tert-butylcalix[4]arene for the determination of lead(II) in environmental samples. , 2013, Analytical chemistry.

[9]  Dermot Diamond,et al.  Screen-printed electrodes for environmental monitoring of heavy metal ions: a review , 2016, Microchimica Acta.

[10]  Jun Zhao,et al.  Analysis of the spatio-temporal variability of seawater quality in the southeastern Arabian Gulf. , 2016, Marine pollution bulletin.

[11]  Marta Novell,et al.  A novel miniaturized radiofrequency potentiometer tag using ion-selective electrodes for wireless ion sensing. , 2013, The Analyst.

[12]  E. Bakker Electroanalysis with Membrane Electrodes and Liquid-Liquid Interfaces. , 2016, Analytical chemistry.

[13]  Jin-Woo Choi,et al.  Disposable smart lab on a chip for point-of-care clinical diagnostics , 2004, Proceedings of the IEEE.

[14]  Philippe Bühlmann,et al.  Calibration-free ionophore-based ion-selective electrodes with a Co(II)/Co(III) redox couple-based solid contact. , 2014, Analytical chemistry.

[15]  F. Rius,et al.  Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers. , 2008, Analytical chemistry.

[16]  Robyn N Conmy,et al.  Submersible optical sensors exposed to chemically dispersed crude oil: wave tank simulations for improved oil spill monitoring. , 2014, Environmental science & technology.

[17]  G. Crespo,et al.  In-Line Acidification for Potentiometric Sensing of Nitrite in Natural Waters. , 2017, Analytical chemistry.

[18]  G. Crespo,et al.  In Situ Ammonium Profiling Using Solid-Contact Ion-Selective Electrodes in Eutrophic Lakes. , 2015, Analytical chemistry.

[19]  Eric Bakker,et al.  Polyurethane Ionophore-Based Thin Layer Membranes for Voltammetric Ion Activity Sensing. , 2016, Analytical chemistry.

[20]  Dermot Diamond,et al.  Guidelines for Improving the Lower Detection Limit of Ion‐Selective Electrodes: A Systematic Approach , 2007 .

[21]  David Hannah,et al.  Real-time monitoring of nutrients and dissolved organic matter in rivers: Capturing event dynamics, technological opportunities and future directions. , 2016, The Science of the total environment.

[22]  Eric Bakker,et al.  All-solid-state potentiometric sensors with a multiwalled carbon nanotube inner transducing layer for anion detection in environmental samples. , 2015, Analytical chemistry.

[23]  Jean-Louis Marty,et al.  Disposable Screen Printed Electrochemical Sensors: Tools for Environmental Monitoring , 2014, Sensors.

[24]  G. Crespo,et al.  GalvaPot, a custom-made combination galvanostat/potentiostat and high impedance potentiometer for decentralized measurements of ionophore-based electrodes , 2015 .

[25]  Samantha T. Mensah,et al.  Nanomolar detection limits of Cd²⁺, Ag⁺, and K⁺ using paper-strip ion-selective electrodes. , 2014, Analytical chemistry.

[26]  Mustafa Yücel,et al.  Marine chemical technology and sensors for marine waters: potentials and limits. , 2009, Annual review of marine science.

[27]  B. Wehrli,et al.  Submicromolar Oxygen Profiles at the Oxic–Anoxic Boundary of Temperate Lakes , 2013, Aquatic Geochemistry.

[28]  A. Radu,et al.  Robust and Ultrasensitive Polymer Membrane-Based Carbonate-Selective Electrodes. , 2015, Analytical chemistry.

[29]  Clare E. Reimers,et al.  In Situ Deployment of Voltammetric, Potentiometric, and Amperometric Microelectrodes from a ROV To Determine Dissolved O2, Mn, Fe, S(-2), and pH in Porewaters , 1999 .

[30]  Martial Taillefert,et al.  Remote in situ voltammetric techniques to characterize the biogeochemical cycling of trace metals in aquatic systems. , 2008, Journal of environmental monitoring : JEM.

[31]  Joseph Wang,et al.  Wearable Electrochemical Sensors and Biosensors: A Review , 2013 .

[32]  W. Schlager,et al.  Carbonates and relative changes in sea level , 1981 .

[33]  A. Stein,et al.  Rational design of all-solid-state ion-selective electrodes and reference electrodes , 2016 .

[34]  M. Yücel,et al.  Compact autonomous voltammetric sensor for sulfide monitoring in deep sea vent habitats , 2013 .

[35]  J. Hudson,et al.  Rapid estimation of phosphate at picomolar concentrations in freshwater lakes with potential application to P-limited marine systems , 2005, Aquatic Sciences.

[36]  R. Byrne Measuring ocean acidification: new technology for a new era of ocean chemistry. , 2014, Environmental science & technology.

[37]  Róbert E. Gyurcsányi,et al.  Quality control criteria for solid-contact, solvent polymeric membrane ion-selective electrodes , 2009 .

[38]  W. Schuhmann,et al.  Prussian Blue Analogues: A Versatile Framework for Solid-Contact Ion-Selective Electrodes with Tunable Potentials , 2017 .

[39]  S. Maggi,et al.  Seasonal and spatial variability of water quality parameters in the Port of Genoa, Italy, from 2000 to 2007. , 2011, Marine pollution bulletin.

[40]  A. Michalska All‐Solid‐State Ion Selective and All‐Solid‐State Reference Electrodes , 2012 .

[41]  R. Schasfoort,et al.  TUTORIAL REVIEW , 2001 .

[42]  Francisco J. Andrade,et al.  Balloon‐Embedded Sensors Withstanding Extreme Multiaxial Stretching and Global Bending Mechanical Stress: Towards Environmental and Security Monitoring , 2016 .

[43]  Luca Fiorani,et al.  Submersible Spectrofluorometer for Real-Time Sensing of Water Quality , 2015, Sensors.

[44]  J. Bobacka,et al.  New Signal Readout Principle for Solid-Contact Ion-Selective Electrodes. , 2016, Analytical chemistry.

[45]  Dermot Diamond,et al.  Opportunities and challenges of using ion-selective electrodes in environmental monitoring and wearable sensors , 2012 .

[46]  D. Schindler,et al.  Phosphate concentrations in lakes , 2000, Nature.

[47]  G. Crespo,et al.  Thin Layer Samples Controlled by Dynamic Electrochemistry. , 2015, Chimia.

[48]  Ning He,et al.  Pre-Polarized Hydrophobic Conducting Polymer Solid-Contact Ion-Selective Electrodes with Improved Potential Reproducibility. , 2017, Analytical chemistry.

[49]  B. Wehrli,et al.  Measurement of Denitrification in Sediments with the 15N Isotope Pairing Technique , 2001, Applied and Environmental Microbiology.

[50]  A. Zirino,et al.  Measurement and prediction of copper ion activity in lake orta, Italy , 1991 .

[51]  Francesco Pomati,et al.  Potentiometric sensing array for monitoring aquatic systems. , 2015, Environmental science. Processes & impacts.

[52]  Eric Bakker,et al.  Tandem electrochemical desalination-potentiometric nitrate sensing for seawater analysis. , 2015, Analytical chemistry.

[53]  Dermot Diamond,et al.  An integrated sensing and wireless communications platform for sensing sodium in sweat , 2016 .

[54]  A. Ivaska,et al.  Potentiometric ion sensors. , 2008, Chemical reviews.

[55]  J. Bobacka,et al.  Solid-contact lead(II) ion-selective electrodes for potentiometric determination of lead(II) in presence of high concentrations of Na(I), Cu(II), Cd(II), Zn(II), Ca(II) and Mg(II) , 2015 .

[56]  F. Graziottin,et al.  Gel‐Integrated Voltammetric Microsensors and Submersible Probes as Reliable Tools for Environmental Trace Metal Analysis and Speciation , 2008 .

[57]  Beat Müller,et al.  Mineralization pathways in lake sediments with different oxygen and organic carbon supply , 2009 .

[58]  Ernö Pretsch,et al.  Lowering the detection limit of solvent polymeric ion-selective electrodes. 1. Modeling the influence of steady-state ion fluxes , 1999 .

[59]  Philippe Bühlmann,et al.  Ionic Liquid Reference Electrodes With a Well-Controlled Co(II)/Co(III) Redox Buffer as Solid Contact , 2015 .

[60]  S. N. White,et al.  Optical tools for ocean monitoring and research , 2008 .

[61]  R. de Marco,et al.  Coulometric sodium chloride removal system with Nafion membrane for seawater sample treatment. , 2012, Analytical chemistry.

[62]  M. Ramírez-Silva,et al.  Ion-Selective Electrodes for Mercury Determination at Low Concentrations: Construction, Optimization and Application , 2016 .

[63]  A. Bissett,et al.  A microsensor for carbonate ions suitable for microprofiling in freshwater and saline environments , 2008 .

[64]  Eric Bakker,et al.  Thin-Layer Chemical Modulations by a Combined Selective Proton Pump and pH Probe for Direct Alkalinity Detection. , 2015, Angewandte Chemie.

[65]  G. Crespo,et al.  Local Acidification of Membrane Surfaces for Potentiometric Sensing of Anions in Environmental Samples. , 2016, ACS sensors.

[66]  G. Crespo,et al.  Exhaustive thin-layer cyclic voltammetry for absolute multianalyte halide detection. , 2014, Analytical chemistry.

[67]  J. J. Morgan,et al.  Aquatic Chemistry: Chemical Equilibria and Rates in Natural Waters , 1970 .

[68]  Johan Bobacka,et al.  Electrochemical control of the standard potential of solid-contact ion-selective electrodes having a conducting polymer as ion-to-electron transducer , 2014 .

[69]  J. Bobacka,et al.  Instrument-free control of the standard potential of potentiometric solid-contact ion-selective electrodes by short-circuiting with a conventional reference electrode. , 2014, Analytical chemistry.

[70]  Joseph Wang,et al.  Electrochemical biosensors: towards point-of-care cancer diagnostics. , 2006, Biosensors & bioelectronics.

[71]  Ning Wang,et al.  Review: Wireless sensors in agriculture and food industry-Recent development and future perspective , 2006 .

[72]  B. Pejcic,et al.  Ion-Selective Electrode Potentiometry in Environmental Analysis , 2007 .

[73]  Xiaobo Zou,et al.  Hybrid-power wireless electrochemical platform coupled to screen-printed electrode module for natural water monitoring , 2017 .

[74]  Richard A. Feely,et al.  Spectrophotometric measurement of calcium carbonate saturation states in seawater. , 2013, Environmental science & technology.

[75]  Beat Müller,et al.  Microscale mineralization pathways in surface sediments: A chemical sensor study in Lake Baikal , 2006 .

[76]  G. Crespo,et al.  Alkalinization of Thin Layer Samples with a Selective Proton Sink Membrane Electrode for Detecting Carbonate by Carbonate-Selective Electrodes. , 2016, Analytical chemistry.

[77]  Timothy M. Shank,et al.  Use of voltammetric solid-state (micro)electrodes for studying biogeochemical processes: Laboratory measurements to real time measurements with an in situ electrochemical analyzer (ISEA) , 2008 .

[78]  J. Riu,et al.  Nanostructured materials in potentiometry , 2011, Analytical and bioanalytical chemistry.

[79]  Robust Solid-Contact Ion Selective Electrodes for High-Resolution In Situ Measurements in Fresh Water Systems , 2017 .

[80]  D. Connelly,et al.  Developments in marine pCO2 measurement technology; towards sustained in situ observations , 2017 .

[81]  A. Hemmi,et al.  A flow electrolysis cell with a thin aqueous phase and a thin organic phase for the absolute determination of trace ionic species , 2013 .

[82]  Dermot Diamond,et al.  Combining Remote Temperature Sensing with in-Situ Sensing to Track Marine/Freshwater Mixing Dynamics , 2016, Sensors.

[83]  Ernö Pretsch,et al.  Potentiometric sensors for trace-level analysis. , 2005, Trends in analytical chemistry : TRAC.

[84]  Mathieu Lepot,et al.  Recent Trends in Monitoring of European Water Framework Directive Priority Substances Using Micro-Sensors: A 2007–2009 Review , 2010, Sensors.

[85]  E. Pretsch,et al.  Approaches to Improving the Lower Detection Limit of Polymeric Membrane Ion-Selective Electrodes. , 2006, Electroanalysis.

[86]  M. Kühl,et al.  A microsensor study of light enhanced Ca2+ uptake and photosynthesis in the reef-building hermatypic coral Favia sp. , 2000 .

[87]  R. Crooks,et al.  Electrochemical Desalination for a Sustainable Water Future , 2014 .

[88]  R. Schwarzenbach,et al.  The Challenge of Micropollutants in Aquatic Systems , 2006, Science.

[89]  Joseph Wang,et al.  Tattoo‐Based Wearable Electrochemical Devices: A Review , 2015 .

[90]  Yoon,et al.  Potentiometric evaluation of solvent polymeric carbonate-selective membranes based on molecular tweezer-type neutral carriers , 2000, Analytical chemistry.

[91]  Ernö Pretsch,et al.  Lowering the Detection Limit of Solvent Polymeric Ion-Selective Membrane Electrodes. 2. Influence of Composition of Sample and Internal Electrolyte Solution , 1999 .

[92]  R. Forster,et al.  Ion‐Selective Electrodes in Environmental Analysis , 2000 .

[93]  Robbyn K. Anand,et al.  Supporting Information Electrochemically Mediated Seawater Desalination** , 2022 .

[94]  Eric Bakker,et al.  Thin layer coulometry with ionophore based ion-selective membranes. , 2010, Analytical chemistry.

[95]  G. Crespo,et al.  Dynamic electrochemistry with ionophore based ion-selective membranes , 2013 .

[96]  C. Fay,et al.  Wireless Ion-Selective Electrode Autonomous Sensing System , 2011, IEEE Sensors Journal.

[97]  R. Tauler,et al.  Investigation of Arctic and Antarctic spatial and depth patterns of sea water in CTD profiles using chemometric data analysis , 2014 .

[98]  Dermot Diamond,et al.  Ion selective electrodes in environmental analysis , 2013 .

[99]  G. Luther,et al.  Use of Voltammetry to Monitor O2 Using Au/Hg Electrodes and to Control Physical Sensors on an Unattended Observatory in the Delaware Bay , 2007 .

[100]  Eric Bakker,et al.  Paper-based thin-layer coulometric sensor for halide determination. , 2015, Analytical chemistry.

[101]  D. de Beer,et al.  A fast‐responding CO2 microelectrode for profiling sediments, microbial mats, and biofilms , 1997 .

[102]  E. Pretsch,et al.  Large Improvement of the Lower Detection Limit of Ion-Selective Polymer Membrane Electrodes , 1997 .

[103]  Beat Müller,et al.  High spatial resolution measurements in lake sediments with PVC based liquid membrane ion‐selective electrodes , 1998 .

[104]  S. Kounaves,et al.  Solid Contact Ion-Selective Electrodes for in Situ Measurements at High Pressure. , 2017, Analytical chemistry.

[105]  Leo M.L. Nollet,et al.  Handbook of Water Analysis , 2013 .

[106]  F. Rius,et al.  Rubber-based substrates modified with carbon nanotubes inks to build flexible electrochemical sensors. , 2014, Analytica chimica acta.

[107]  G. Crespo,et al.  Phenytoin speciation with potentiometric and chronopotentiometric ion-selective membrane electrodes. , 2016, Biosensors & bioelectronics.