Reproducibility of Image-Based Computational Fluid Dynamics Models of the Human Carotid Bifurcation

AbstractRecent studies have demonstrated the ability of magnetic resonance imaging (MRI) to provide anatomically realistic boundary conditions for computational fluid dynamics (CFD) simulations of arterial hemodynamics. To date, however, little is known about the overall reproducibility of such image-based CFD techniques. Towards this end we used serial black blood and cine phase contrast MRI to reconstruct CFD models of the carotid bifurcations of three subjects with early atherosclerosis, each imaged three times at weekly intervals. The lumen geometry was found to be precise on average to within 0.15 mm or 5%, while measured flow and heart rates varied by less than 10%. Spatial patterns of a variety of wall shear stress (WSS) indices were largely preserved among the three repeat models. Time-averaged WSS was reproduced best, on average to within 5 dyn/cm2 or 37%, followed by WSS spatial gradients, angle gradients, and oscillatory shear index. The intrasubject flow rate variations were found to contribute little to the overall WSS variability. Instead, reproducibility was determined largely by the precision of the lumen boundary extraction from the individual MR images, itself shown to be a function of the image quality and proximity to the geometrically complex bifurcation region. © 2003 Biomedical Engineering Society. PAC2003: 8761Lh, 8757Nk, 8719Hh, 8719Rr, 8719Uv

[1]  D. Ku,et al.  Hemodynamics and atherosclerosis. Insights and perspectives gained from studies of human arteries. , 1988, Archives of pathology & laboratory medicine.

[2]  D D Duncan,et al.  Effects of arterial compliance and non-Newtonian rheology on correlations between intimal thickness and wall shear. , 1992, Journal of biomechanical engineering.

[3]  D. Ku,et al.  Pulsatile flow in the human left coronary artery bifurcation: average conditions. , 1996, Journal of biomechanical engineering.

[4]  D A Steinman,et al.  Computational blood flow modelling: errors associated with reconstructing finite element models from magnetic resonance images. , 1997, Journal of biomechanics.

[5]  B. Rutt,et al.  Hemodynamics of human carotid artery bifurcations: computational studies with models reconstructed from magnetic resonance imaging of normal subjects. , 1998, Journal of vascular surgery.

[6]  C Yuan,et al.  Closed contour edge detection of blood vessel lumen and outer wall boundaries in black-blood MR images. , 1999, Magnetic resonance imaging.

[7]  D. Liepsch,et al.  Flow Characteristics in an Anatomically Realistic Compliant Carotid Artery Bifurcation Model. , 1999, Computer methods in biomechanics and biomedical engineering.

[8]  C. R. Ethier,et al.  A characteristic/finite element algorithm for the 3-D Navier–Stokes equations using unstructured grids , 1999 .

[9]  C. R. Ethier,et al.  A numerical study of blood flow patterns in anatomically realistic and simplified end-to-side anastomoses. , 1999, Journal of biomechanical engineering.

[10]  C. Taylor,et al.  Predictive medicine: computational techniques in therapeutic decision-making. , 1999, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[11]  S. Alper,et al.  Hemodynamic shear stress and its role in atherosclerosis. , 1999, JAMA.

[12]  N Alperin,et al.  Improved phase-contrast flow quantification by three-dimensional vessel localization. , 2000, Magnetic resonance imaging.

[13]  A D Hughes,et al.  Blood flow and vessel mechanics in a physiologically realistic model of a human carotid arterial bifurcation. , 2000, Journal of biomechanics.

[14]  R Greene,et al.  Pulsatile flow simulation in arterial vascular segments with intravascular ultrasound images. , 2001, Medical engineering & physics.

[15]  D A Steinman,et al.  Effect of black blood MR image quality on vessel wall segmentation , 2001, Magnetic resonance in medicine.

[16]  Clement Kleinstreuer,et al.  Computational particle-hemodynamics analysis and geometric reconstruction after carotid endarterectomy , 2001, Comput. Biol. Medicine.

[17]  D A Steinman,et al.  A semi-automatic technique for measurement of arterial wall from black blood MRI. , 2001, Medical physics.

[18]  G. Truskey,et al.  Hemodynamic parameters and early intimal thickening in branching blood vessels. , 2001, Critical reviews in biomedical engineering.

[19]  C. Kerber,et al.  Analysis of slipstream flow in a wide-necked basilar artery aneurysm: evaluation of potential treatment regimens. , 2001, AJNR. American journal of neuroradiology.

[20]  B. Rutt,et al.  Reconstruction of carotid bifurcation hemodynamics and wall thickness using computational fluid dynamics and MRI , 2002, Magnetic resonance in medicine.

[21]  David A Steinman,et al.  On the influence of vessel planarity on local hemodynamics at the human carotid bifurcation. , 2002, Biorheology.

[22]  C. R. Ethier,et al.  Factors Influencing Blood Flow Patterns in the Human Right Coronary Artery , 2001, Annals of Biomedical Engineering.

[23]  B. Rutt,et al.  Computational Blood Flow Modeling Based on In Vivo Measurements , 1999, Annals of Biomedical Engineering.

[24]  David A. Steinman,et al.  Image-Based Computational Fluid Dynamics Modeling in Realistic Arterial Geometries , 2002, Annals of Biomedical Engineering.

[25]  C. R. Ethier,et al.  Accuracy of Computational Hemodynamics in Complex Arterial Geometries Reconstructed from Magnetic Resonance Imaging , 2004, Annals of Biomedical Engineering.

[26]  M. Czerny,et al.  Fluid Dynamics, Wall Mechanics, and Oxygen Transfer in Peripheral Bypass Anastomoses , 2002, Annals of Biomedical Engineering.

[27]  博 三岡,et al.  大腿膝窩動脈バイパスの末梢吻合部におけるカフ付き吻合のimage based computational fluid dynamics , 2006 .