Linear sweep anodic stripping voltammetry of heavy metals from nitrogen doped tetrahedral amorphous carbon thin films

Abstract Nitrogen doped tetrahedral amorphous carbon (ta-C:N) thin films were deposited on p-Si (1 1 1) substrates (1 × 10 −3 to 6 × 10 −3  Ω cm) by a filtered cathodic vacuum arc technique with different nitrogen flow rates (3 and 20 sccm). The ta-C:N film coated samples were used as working electrodes to detect trace heavy metals such as zinc (Zn), lead (Pb), copper (Cu) and mercury (Hg) by using linear sweep anodic stripping voltammetry in 0.1 M KCl solutions (pH 1). The influence of nitrogen flow rate on the sensitivity of the films to the metal ions was investigated. The results showed that the current response of the ta-C:N film electrodes was significant to differentiate all the tested trace metal ions (Zn 2+ , Pb 2+ , Cu 2+ , and Hg 2+ ) and the three ions (Pb 2+  + Cu 2+  + Hg 2+ ) could be simultaneously identified with good stripping peak potential separations.

[1]  E. Liu,et al.  Stripping Voltammetric Analysis of Heavy Metals at Nitrogen Doped Diamond‐Like Carbon Film Electrodes , 2002 .

[2]  R. Compton,et al.  Sono-cathodic stripping voltammetry of manganese at a polished boron-doped diamond electrode: application to the determination of manganese in instant tea. , 1999, The Analyst.

[3]  P. Barbeira,et al.  Voltammetric Determination of Chloride Ion in Automotive Fuel Ethanol , 2008 .

[4]  R. Wightman,et al.  Cyclic voltammetry and anodic stripping voltammetry with mercury ultramicroelectrodes , 1985 .

[5]  Qingyun Chen,et al.  Peer Reviewed: Boron-Doped Diamond Thin-Film Electrodes , 1997 .

[6]  E. Liu,et al.  Cyclic Voltammetric Behavior of Nitrogen-Doped Tetrahedral Amorphous Carbon Films Deposited by Filtered Cathodic Vacuum Arc , 2008 .

[7]  E. Liu,et al.  Nitrogenated diamond-like carbon films for metal tracing , 2005 .

[8]  Jaco Vangronsveld,et al.  Biosensors for detection of mercury in contaminated soils. , 2004, Environmental pollution.

[9]  K. Boey,et al.  Chronic neurobehavioural effects of elemental mercury in dentists. , 1992, British journal of industrial medicine.

[10]  E. Smith,et al.  Excessive oral zinc supplementation. , 2002, Journal of pediatric hematology/oncology.

[11]  Nicole Jaffrezic-Renault,et al.  Anodic Stripping Voltammetry of Heavy Metals at Nanocrystalline Boron‐Doped Diamond Electrode , 2007 .

[12]  M. C. Granger,et al.  Morphological and Microstructural Stability of Boron‐Doped Diamond Thin Film Electrodes in an Acidic Chloride Medium at High Anodic Current Densities , 1997 .

[13]  H. Cachet,et al.  On the relation between microstructure and electrochemical reactivity of sputtered amorphous carbon nitride electrodes , 2007 .

[14]  Jacques Buffle,et al.  In situ voltammetric measurements in natural waters: Future prospects and challenges , 1993 .

[15]  L H Li,et al.  Psychological effects of low exposure to mercury vapor: application of a computer-administered neurobehavioral evaluation system. , 1993, Environmental research.

[16]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[17]  B. Tay,et al.  Electronic transport properties of nitrogen doped amorphous carbon films deposited by the filtered cathodic vacuum arc technique , 1998 .

[18]  O. Fatoki,et al.  Levels of trace metals in water and sediment from Tyume River and its effects on an irrigated farmland , 2005 .

[19]  F. Marken,et al.  Simultaneous Electrochemical Detection and Determination of Lead and Copper at Boron‐Doped Diamond Film Electrodes , 2002 .

[20]  E. Liu,et al.  Cyclic Voltammetry Studies of Sputtered Nitrogen Doped Diamond‐Like Carbon Film Electrodes , 2002 .

[21]  M. Baldo,et al.  Lead and copper deposition from dilute solutions onto carbon disc microelectrodes. Assessment of quantification procedures by anodic stripping voltammetry , 1998 .

[22]  J. Robertson,et al.  Interpretation of Raman spectra of disordered and amorphous carbon , 2000 .

[23]  J. Zen,et al.  Determination of lead(II) on a copper/mercury-plated screen-printed electrode , 2000 .

[24]  R. Mcfarland,et al.  Chronic mercury poisoning from a single brief exposure. , 1978, Journal of occupational medicine. : official publication of the Industrial Medical Association.

[25]  J. Osteryoung,et al.  Pulse voltammetric techniques applied to the anodization of copper microelectrodes , 1993 .

[26]  H. F. Kraybill,et al.  Toxic effects of cadmium: a review. , 1971, Environmental research.

[27]  Mark P. Taylor,et al.  Sono-cathodic stripping voltammetry of lead at a polished boron-doped diamond electrode: Application to the determination of lead in river sediment , 1999 .

[28]  R. Compton,et al.  Comparative Study to Evaluate the Feasibility of Sono-Anodic and Sono-Cathodic Stripping Voltammetry for the Determination of Pb in a Cu-Pb Alloy , 2000 .

[29]  James Alastair McLaughlin,et al.  Bonding configurations in DBOP-FCVA nitrogenated tetrahedral amorphous carbon films studied by Raman and X-ray photoelectron spectroscopies , 2004 .