Reuse of Data Center Waste Heat in Nearby Neighborhoods: A Neural Networks-Based Prediction Model

This paper addresses the problem of data centers’ cost efficiency considering the potential of reusing the generated heat in district heating networks. We started by analyzing the requirements and heat reuse potential of a high performance computing data center and then we had defined a heat reuse model which simulates the thermodynamic processes from the server room. This allows estimating by means of Computational Fluid Dynamics simulations the temperature of the hot air recovered by the heat pumps from the server room allowing them to operate more efficiently. To address the time and space complexity at run-time we have defined a Multi-Layer Perceptron neural network infrastructure to predict the hot air temperature distribution in the server room from the training data generated by means of simulations. For testing purposes, we have modeled a virtual server room having a volume of 48 m3 and two typical 42U racks. The results show that using our model the heat distribution in the server room can be predicted with an error less than 1 °C allowing data centers to accurately estimate in advance the amount of waste heat to be reused and the efficiency of heat pump operation.

[1]  Graeme Maidment,et al.  Using data centres for combined heating and cooling: An investigation for London , 2016 .

[2]  Geoffrey C. Fox,et al.  Task scheduling with ANN-based temperature prediction in a data center: a simulation-based study , 2011, Engineering with Computers.

[3]  Jahar Sarkar,et al.  Performance of a Transcritical CO2 Heat Pump for Simultaneous Water Cooling and Heating , 2009 .

[4]  Bahgat Sammakia,et al.  Neural Network Modeling in Model-Based Control of a Data Center , 2015 .

[5]  Jeffrey S. Chase,et al.  Making Scheduling "Cool": Temperature-Aware Workload Placement in Data Centers , 2005, USENIX Annual Technical Conference, General Track.

[6]  Jaume Salom,et al.  Energy-efficient, thermal-aware modeling and simulation of data centers: The CoolEmAll approach and evaluation results , 2015, Ad Hoc Networks.

[7]  Miika Rämä,et al.  Models for fast modelling of district heating and cooling networks , 2018 .

[8]  Kelum A. A. Gamage,et al.  Forecasting Hot Water Consumption in Residential Houses , 2015 .

[9]  Yogendra Joshi,et al.  Rapid Temperature Predictions in Data Centers using Multi-Parameter Proper Orthogonal Decomposition , 2014 .

[10]  Marcel Antal,et al.  DC Thermal Energy Flexibility Model for Waste Heat Reuse in Nearby Neighborhoods , 2017, e-Energy.

[11]  Vishok Amar Kumar Real Time Temperature Prediction In A Data Center Environment Using An Adaptive Algorithm , 2014 .

[12]  Jinkyun Cho,et al.  Evaluation of air distribution system's airflow performance for cooling energy savings in high-density data centers , 2014 .

[13]  Morten Boje Blarke,et al.  Thermal battery with CO2 compression heat pump: Techno-economic optimization of a high-efficiency Smart Grid option for buildings , 2012 .

[14]  Marcel Antal,et al.  Transforming Data Centers in Active Thermal Energy Players in Nearby Neighborhoods , 2018 .

[15]  Jukka Manner,et al.  Utilizing data center waste heat in district heating – Impacts on energy efficiency and prospects for low-temperature district heating networks , 2017 .

[16]  Ariel Oleksiak,et al.  Energy and thermal models for simulation of workload and resource management in computing systems , 2015, Simul. Model. Pract. Theory.

[17]  Giovanni Giuliani,et al.  A methodology to predict the power consumption of servers in data centres , 2011, e-Energy.

[18]  Morgane Colombert,et al.  Recov’Heat: An estimation tool of urban waste heat recovery potential in sustainable cities , 2017 .

[19]  Jessica Lind,et al.  Industrial Symbiosis in Heat Recovery Collaborations between Data Centers and District Heating and Cooling Companies , 2017 .

[20]  Suman Nath,et al.  ThermoCast: a cyber-physical forecasting model for datacenters , 2011, KDD.

[21]  B. Zhang,et al.  Simulation of Thermal Distribution and Airflow for Efficient Energy Consumption in a Small Data Centers , 2017 .

[22]  Sami Alkharabsheh,et al.  Dynamic models for server rack and CRAH in a room level CFD model of a data center , 2014, Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm).

[23]  Ariel Oleksiak,et al.  Modeling Impact of Power- and Thermal-Aware Fans Management on Data Center Energy Consumption , 2015, e-Energy.

[24]  Jaume Salom,et al.  Minimization of Costs and Energy Consumption in a Data Center by a Workload-Based Capacity Management , 2014, E2DC.

[25]  Qinghui Tang,et al.  Sensor-Based Fast Thermal Evaluation Model For Energy Efficient High-Performance Datacenters , 2006, 2006 Fourth International Conference on Intelligent Sensing and Information Processing.