Mechanisms of hemolysis with mitral prosthetic regurgitation. Study using transesophageal echocardiography and fluid dynamic simulation.

OBJECTIVES The aims of this study were to define the hydrodynamic mechanisms involved in the occurrence of hemolysis in prosthetic mitral valve regurgitation and to reproduce them in a numeric simulation model in order to estimate peak shear stress. BACKGROUND Although in vitro studies have demonstrated that shear stresses > 3,000 dynes/cm2 are associated with significant erythrocyte destruction, it is not known whether these values can occur in vivo in conditions of abnormal prosthetic regurgitant flow. METHODS We studied 27 patients undergoing reoperation for significant mitral prosthetic regurgitation, 16 with and 11 without hemolysis. We classified the origin and geometry of the regurgitant jets by using transesophageal echocardiography. By using the physical and morphologic characteristics defined, several hydrodynamic patterns were simulated numerically to determine shear rates. RESULTS Eight (50%) of the 16 patients with hemolysis had paravalvular leaks and the other 8 had a jet with central origin, in contrast to 2 (18%) and 9 (82%), respectively, of the 11 patients without hemolysis (p = 0.12, power 0.38). Patients with hemolysis had patterns of flow fragmentation (n = 2), collision (n = 11) or rapid acceleration (n = 3), whereas those without hemolysis had either free jets (n = 7) or slow deceleration (n = 4) (p < 0.001, power 0.99). Numeric simulation demonstrated peak shear rates of 6,000, 4,500, 4,500, 925 and 950 dynes/cm2 in these five models, respectively. CONCLUSIONS The distinct patterns of regurgitant flow seen in these patients with mitral prosthetic hemolysis were associated with rapid acceleration and deceleration or high peak shear rates, or both. The nature of the flow disturbance produced by the prosthetic regurgitant lesion and the resultant increase in shear stress are more important than the site of origin of the flow disturbance in producing clinical hemolysis.

[1]  A. Bolger,et al.  Transesophageal two-dimensional echocardiography and color Doppler flow velocity mapping in the evaluation of cardiac valve prostheses. , 1988, Circulation.

[2]  Alfrey Cp,et al.  Erythrocyte damage and destruction induced by shearing stress. , 1968 .

[3]  Dwight E. Harken,et al.  Aortic valve replacement with a gaged ball valve , 1962 .

[4]  Randolph P. Martin,et al.  Improvement in the diagnosis of abscesses associated with endocarditis by transesophageal echocardiography. , 1991, The New England journal of medicine.

[5]  R. E. Clark,et al.  The clinical life history of explanted prosthetic heart valves. , 1982, The Annals of thoracic surgery.

[6]  M. Engler,et al.  Actuarial analysis of the risk of undergoing repeat cardiac valve replacement. , 1984, American journal of surgery.

[7]  J. Rothchild,et al.  Chronic Intravascular Hemolysis after Aortic Valve Replacement: Long‐Term Study Comparing Different Types of Ball‐Valve Prostheses , 1971, Circulation.

[8]  A Mügge,et al.  Echocardiography in infective endocarditis: reassessment of prognostic implications of vegetation size determined by the transthoracic and the transesophageal approach. , 1989, Journal of the American College of Cardiology.

[9]  H. Soroff,et al.  Partial and complete prostheses in aortic insufficiency. , 1960, The Journal of thoracic and cardiovascular surgery.

[10]  A. Starr,et al.  Mitral Replacement: Clinical Experience with a Ball‐Valve Prosthesis , 1961, Annals of surgery.

[11]  R. Weed,et al.  Membrane alterations leading to red cell destruction. , 1966, The American journal of medicine.

[12]  D. Sabiston,et al.  Hemolytic Anemia Following Prosthetic Valve Replacement , 1969, Circulation.

[13]  R. E. Clark,et al.  Late clinical problems with Beall model 103 and 104 mitral valve prostheses: hemolysis and valve wear. , 1976, The Annals of thoracic surgery.

[14]  B. Pirofsky Hemolysis in Valvular Heart Disease , 1966 .

[15]  R. Anderson,et al.  Clinical and hemodynamic results with the St. Jude medical aortic valve prosthesis. , 1979, Surgical forum.

[16]  J. Kastor,et al.  Paravalvular leaks and hemolytic anemia following insertion of Starr-Edwards aortic and mitral valves. , 1968, The Journal of thoracic and cardiovascular surgery.

[17]  S. Rajah,et al.  Chronic haemolysis after Lillehei-Kaster valve replacement. Comparison with the findings after Björk-shiley and Starr-Edwards mitral valve replacement. , 1980, Thorax.

[18]  G. Marx,et al.  Dynamic Three‐Dimensional Echocardiography: , 1994 .

[19]  A. Labovitz,et al.  Effect of mitral regurgitation on pulmonary venous velocities derived from transesophageal echocardiography color-guided pulsed Doppler imaging. , 1991, Journal of the American College of Cardiology.

[20]  C. Hufnagel,et al.  HEMOLYTIC ANEMIA OF MECHANICAL ORIGIN WITH AORTIC-VALVE PROSTHESIS. , 1965, The New England journal of medicine.

[21]  J D Hellums,et al.  Red blood cell damage by shear stress. , 1972, Biophysical journal.

[22]  W L Nyborg,et al.  Hemolysis Near a Transversely Oscillating Wire , 1970, Science.

[23]  H. Griswold,et al.  Red Blood Cell Survival in Patients with Aortic Valvular Disease and Ball‐Valve Prostheses , 1965, Circulation.

[24]  S. I. Shapiro,et al.  Hemolysis in simple shear flows , 1970 .

[25]  J. R. Walsh,et al.  Intravascular Hemolysis in Patients with Prosthetic Valves and Valvular Heart Disease , 1969, Circulation.

[26]  J. T. Santinga,et al.  Hemolysis in the aortic prosthetic valve. , 1976, Chest.

[27]  R. Rand,et al.  MECHANICAL PROPERTIES OF THE RED CELL MEMBRANE. II. VISCOELASTIC BREAKDOWN OF THE MEMBRANE. , 1964, Biophysical journal.

[28]  H. W. Ramsey,et al.  Complications following destruction of the cloth covering of a Starr-Edwards aortic valve prosthesis. , 1971, The Journal of thoracic and cardiovascular surgery.

[29]  D. Ross,et al.  Cloth destruction and haemolysis with totally cloth-covered Starr-Edwards prostheses , 1971, Thorax.

[30]  J. T. Santinga,et al.  Hemolytic anemia in series 2300 and 2310 Starr-Edwards prosthetic valves. , 1972, The Annals of thoracic surgery.

[31]  A. Labovitz,et al.  Quantitation of mitral regurgitation by transesophageal echocardiography with Doppler color flow mapping: correlation with cardiac catheterization. , 1992, Journal of the American College of Cardiology.

[32]  A C BURTON,et al.  MECHANICAL PROPERTIES OF THE RED CELL MEMBRANE. I. MEMBRANE STIFFNESS AND INTRACELLULAR PRESSURE. , 1964, Biophysical journal.