Development of a non-invasive treatment system for urinary incontinence using a functional continuous magnetic stimulator (FCMS)

A system composed of a functional continuous magnetic stimulator (FCMS) and a saddle-type coil has been developed for non-invasive treatment of urinary incontinence, especially stress incontinence and urge incontinence. The FCMS conditions were as follows: 2 kW maximum electrical power consumption, 800 V maximum capacitor voltage, 720 μs pulsewidth (180 μs rise time), and 5–30 Hz frequency. A frequency between 5 and 10 Hz is used to treat urge incontinence and a frequency between 25 Hz and 30 Hz is used to treat urge incontinence. The coil (120 mm long, 90 mm wide and 50 mm thick) fits the most suitable region for this treatment, the region from the anus to the perineum. The coil is cooled to maintain a coil temperature between 20 and 25°C so that it can be used efficiently and safely. In experiments with anaesthetised dogs, it was confirmed that the urethral pressure increased when the circumference of the perineum received continuous magnetic stimulation of 720 μs pulsewidth (180 μs rise time), 10Hz frequency and about 520 V capacitor voltage. This result suggests that magnetic stimulation can be effective as a urinary incontinence therapy.

[1]  H. Hosaka,et al.  Eddy current density for non-invasive treatment system for urinary incontinence using Functional Continuous Magnetic Stimulator (FCMS) , 1998, Proceedings of the 2nd International Conference on Bioelectromagnetism (Cat. No.98TH8269).

[2]  S. Bergmann,et al.  Maximal electrostimulation of the pelvic floor in female idiopathic detrusor instability and urge incontinence , 1989 .

[3]  M. Hallett,et al.  Determining the site of stimulation during magnetic stimulation of a peripheral nerve. , 1992, Electroencephalography and clinical neurophysiology.

[4]  I. L. Freeston,et al.  Non-invasive stimulation of motor pathways within the brain using time-varying magnetic fields , 1985 .

[5]  R. Schmidt,et al.  Functional pattern of sacral root stimulation in dogs. II. Urethral closure. , 1982, The Journal of urology.

[6]  R. Schmidt,et al.  Functional pattern of sacral root stimulation in dogs. I. Micturition. , 1982, The Journal of urology.

[7]  A. Barker An Introduction to the Basic Principles of Magnetic Nerve Stimulation , 1991, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[8]  B. Conrad,et al.  Comparison of various coils used for magnetic stimulation of peripheral motor nerves: physiological considerations and consequences for diagnostic use. , 1995, Electroencephalography and clinical neurophysiology.

[9]  HARUKA OKINO,et al.  MINIATURIZED BLOOD PRESSURE TRANSDUCER , 1979 .

[10]  J Cadwell,et al.  Optimizing magnetic stimulator design. , 1991, Electroencephalography and clinical neurophysiology. Supplement.

[11]  R. Sakakibara,et al.  Pelvic floor electrical stimulation in the treatment of stress incontinence: an investigational study and a placebo controlled double-blind trial. , 1997, The Journal of urology.

[12]  P. Vrtačnik,et al.  Short-term electrical stimulation: home treatment for urinary incontinence , 1986, World Journal of Urology.

[13]  J. Reilly Peripheral nerve stimulation by induced electric currents: Exposure to time-varying magnetic fields , 1989, Medical and Biological Engineering and Computing.

[14]  Shinji Wakao,et al.  Eddy current computations in moving conductors by the hybrid FE-BE method , 1995 .

[15]  H. Hosaka,et al.  Non-invasive treatment system for urinary incontinence using continuous magnetic stimulation , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[16]  I. L. Freeston,et al.  Stimulation of nerve trunks with time-varying magnetic fields , 1982, Medical and Biological Engineering and Computing.

[17]  P. Basser,et al.  A model of the stimulation of a nerve fiber by electromagnetic induction , 1990, IEEE Transactions on Biomedical Engineering.

[18]  B Klemar,et al.  A new high-frequency magnetic stimulator with an oil-cooled coil. , 1995, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[19]  Garnham Cw,et al.  Magnetic nerve stimulation: the effect of waveform on efficiency, determination of neural membrane time constants and the measurement of stimulator output. , 1991 .

[20]  J Valls-Solé,et al.  Akinesia in Parkinson's disease. II. Effects of subthreshold repetitive transcranial motor cortex stimulation , 1994, Neurology.

[21]  Á. Pascual-Leone,et al.  Induction of speech arrest and counting errors with rapid‐rate transcranial magnetic stimulation , 1991, Neurology.

[22]  J. P. Reilly,et al.  Magnetic field excitation of peripheral nerves and the heart: a comparison of thresholds , 1991, Medical and Biological Engineering and Computing.

[23]  A Struppler,et al.  The boundary effect in magnetic stimulation. Analysis at the peripheral nerve. , 1995, Electroencephalography and clinical neurophysiology.

[24]  Stanislav Plevnik,et al.  Maximal electrical stimulation for urinary incontinence , 1979 .