Solid-beam finite element analysis of Nitinol stents

Abstract This paper discusses the finite element (FE) modelling of Nitinol stent structures by means of a recently introduced solid-beam finite element technology. FE stenting simulations based on standard 3D solid elements are computationally very expensive. An adequate FE discretization of the stent structure requires a large number of elements for two reasons: Several elements are needed in the thickness directions of the stent struts in order to resolve localized martensite transformations. Additionally, due to the slenderness of the struts, a dense discretization in longitudinal direction is required to retain reasonable element aspect ratios. In combination with non-linearities emerging from the non-linear material behaviour, large deformations, and contact, stenting simulations become very challenging and time consuming. The solid-beam finite element technology is considered to reduce computational costs by working with only one element in thickness direction and allowing larger aspect ratios while the results are still acceptable to be used in the iterative design process. The here suggested formulation based on an eight-node brick element geometry is suitable to efficiently model beam-like structures with prismatic cross-sections without the necessity of abstracting the beam axes from the three-dimensional (3D) geometry. All relevant locking phenomena are alleviated by a tailored combination of different techniques. The combination of the new finite element technology with a sophisticated material model that represents the pseudoelastic behaviour of Nitinol is an additional aspect to be investigated in this regard. Validations at the example of an isolated strut show that very accurate results are obtained for thick and thin strut geometries. Moreover, we successfully simulate the crimping–expanding process of an intracranial stent showing a very complex geometry. The results match those based on high density solid meshes very well. The computational benefit becomes clearly evident.

[1]  Stefanie Reese,et al.  On the modelling of non‐linear kinematic hardening at finite strains with application to springback—Comparison of time integration algorithms , 2008 .

[2]  J. F. Caseiro,et al.  On the Assumed Natural Strain method to alleviate locking in solid-shell NURBS-based finite elements , 2014 .

[3]  S. W. Robertson,et al.  Fatigue and durability of Nitinol stents. , 2008, Journal of the mechanical behavior of biomedical materials.

[4]  Vladimir Brailovski,et al.  Finite element modeling of a progressively expanding shape memory stent. , 2006, Journal of biomechanics.

[5]  Stefanie Reese,et al.  Finite deformation pseudo-elasticity of shape memory alloys – Constitutive modelling and finite element implementation , 2008 .

[6]  T. Hughes,et al.  Isogeometric analysis : CAD, finite elements, NURBS, exact geometry and mesh refinement , 2005 .

[7]  Ferdinando Auricchio,et al.  Shape-memory alloys: macromodelling and numerical simulations of the superelastic behavior , 1997 .

[8]  Min Qi,et al.  Delivery and release of nitinol stent in carotid artery and their interactions: a finite element analysis. , 2007, Journal of biomechanics.

[9]  Stefanie Reese,et al.  A reduced integration solid‐shell finite element based on the EAS and the ANS concept—Large deformation problems , 2011 .

[10]  Salim Belouettar,et al.  Optimization Based Simulation of Self-expanding Nitinol Stent , 2013 .

[11]  F. Auricchio,et al.  Evaluation of carotid stent scaffolding through patient-specific finite element analysis. , 2012, International journal for numerical methods in biomedical engineering.

[12]  Neil Morgan,et al.  Medical shape memory alloy applications—the market and its products , 2004 .

[13]  R. Kaplow,et al.  A vena cava filter using thermal shape memory alloy. Experimental aspects. , 1977, Radiology.

[14]  D. Stoeckel,et al.  A survey of stent designs , 2002, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[15]  Tae Jin Kang,et al.  Mechanical modeling of self-expandable stent fabricated using braiding technology. , 2008, Journal of biomechanics.

[16]  Ferdinando Auricchio,et al.  Shape-memory alloys: modelling and numerical simulations of the finite-strain superelastic behavior , 1997 .

[17]  F. Auricchio,et al.  Carotid artery stenting simulation: from patient-specific images to finite element analysis. , 2011, Medical engineering & physics.

[18]  Dirk Helm,et al.  Shape memory behaviour: modelling within continuum thermomechanics , 2003 .

[19]  T. Hughes,et al.  Finite Elements Based Upon Mindlin Plate Theory With Particular Reference to the Four-Node Bilinear Isoparametric Element , 1981 .

[20]  J. C. Simo,et al.  Geometrically non‐linear enhanced strain mixed methods and the method of incompatible modes , 1992 .

[21]  Alessandro Reali,et al.  Locking-free isogeometric collocation methods for spatial Timoshenko rods , 2013 .

[22]  Tom Duerig,et al.  Self-expanding nitinol stents: material and design considerations , 2004, European Radiology.

[23]  Salim Belouettar,et al.  Deployment of a self-expanding stent inside an artery: A finite element analysis , 2012 .

[24]  S. Felber,et al.  A Novel Microcatheter-Delivered, Highly-Flexible and Fully-Retrievable Stent, Specifically Designed for Intracranial Use , 2003, Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences.

[25]  Eduardo N. Dvorkin,et al.  A formulation of general shell elements—the use of mixed interpolation of tensorial components† , 1986 .

[26]  A. Pelton,et al.  An overview of nitinol medical applications , 1999 .

[27]  S. Reese,et al.  On the theoretical and numerical modelling of Armstrong–Frederick kinematic hardening in the finite strain regime , 2004 .

[28]  Stefanie Reese,et al.  A solid-beam finite element and non-linear constitutive modelling , 2013 .

[29]  C. Kleinstreuer,et al.  Computational mechanics of Nitinol stent grafts. , 2008, Journal of biomechanics.

[30]  T W Duerig,et al.  An Overview of Superelastic Stent Design , 2000, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.