Long-term biocompatibility and osseointegration of electron beam melted, free-form–fabricated solid and porous titanium alloy: Experimental studies in sheep

The purpose of the present study was to evaluate the long-term osseointegration and biocompatibility of electron beam melted (EBM) free-form–fabricated (FFF titanium grade 5 (Ti6Al4V) implants. Porous and solid machined cylindrical and disk-shaped implants were prepared by EBM and implanted bilaterally in the femur and subcutaneously in the dorsum of the sheep. After 26 weeks, the implants and surrounding tissue were retrieved. The tissue response was examined qualitatively and quantitatively using histology and light microscopic (LM) morphometry. Selected bone implants specimens were evaluated by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and micro-computed tomography (mCT). The results showed that both porous and solid implants were osseointegrated and high bone–implant contact was observed throughout the porous implant. In the soft tissue, the porous implants showed thinner fibrous encapsulation while no signs of intolerance were observed for either implant type. Taken together, the present experimental results show that FFF Ti6Al4V with and without porous structures demonstrate excellent long-term soft tissue biocompatibility and a high degree of osseointegration. The present findings extend earlier, short-term experimental observations in bone and suggest that EBM, FFF Ti6Al4V implants possess valuable properties in bone and soft tissue applications.

[1]  R. Brånemark,et al.  Acute inflammatory response to laser-induced micro- and nano-sized titanium surface features. , 2013, Clinical implant dentistry and related research.

[2]  Robert F. Singer,et al.  Cellular Titanium by Selective Electron Beam Melting , 2007 .

[3]  D W Hutmacher,et al.  Investigation of microstructural features in regenerating bone using micro computed tomography , 2004, Journal of materials science. Materials in medicine.

[4]  M. Textor,et al.  Effects of surface topography on the connective tissue attachment to subcutaneous implants. , 2006, The International journal of oral & maxillofacial implants.

[5]  Marcus Textor,et al.  Titanium in Medicine : material science, surface science, engineering, biological responses and medical applications , 2001 .

[6]  Anders Snis,et al.  Electron beam-melted, free-form-fabricated titanium alloy implants: Material surface characterization and early bone response in rabbits. , 2008, Journal of biomedical materials research. Part B, Applied biomaterials.

[7]  A. Snis,et al.  Free-Form-Fabricated Commercially Pure Ti and Ti6Al4V Porous Scaffolds Support the Growth of Human Embryonic Stem Cell-Derived Mesodermal Progenitors , 2012, TheScientificWorldJournal.

[8]  R. Brånemark,et al.  Morphological studies on machined implants of commercially pure titanium and titanium alloy (Ti6Al4V) in the rabbit. , 2009, Journal of biomedical materials research. Part B, Applied biomaterials.

[9]  T. Jemt,et al.  Clinical experience of TiUnite implants: a 5-year cross-sectional, retrospective follow-up study. , 2009, Clinical implant dentistry and related research.

[10]  Emeka Nkenke,et al.  Effects of topographical surface modifications of electron beam melted Ti-6Al-4V titanium on human fetal osteoblasts. , 2008, Journal of biomedical materials research. Part A.

[11]  H. Freese,et al.  Metallurgy and Technological Properties of Titanium and Titanium Alloys , 2001 .

[12]  S. Ichinose,et al.  The study of metal ion release and cytotoxicity in Co–Cr–Mo and Ti–Al–V alloy in total knee prosthesis – scanning electron microscopic observation , 2003, Journal of materials science. Materials in medicine.

[13]  B. Kasemo,et al.  Bone response to surface modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology. , 1994, Biomaterials.

[14]  Anders Palmquist,et al.  The correlation between gene expression of proinflammatory markers and bone formation during osseointegration with titanium implants. , 2011, Biomaterials.

[15]  S. Novak,et al.  SiO2 thickness determination by x-ray photoelectron spectroscopy, Auger electron spectroscopy, secondary ion mass spectrometry, Rutherford backscattering, transmission electron microscopy, and ellipsometry , 2000 .

[16]  B. Ratner,et al.  Quantitative characterization of sphere‐templated porous biomaterials , 2005 .

[17]  U. Oron,et al.  Bone growth to metal implants is regulated by their surface chemical properties. , 1993, Biomaterials.

[18]  Ola L. A. Harrysson,et al.  Properties of Ti–6Al–4V non-stochastic lattice structures fabricated via electron beam melting , 2008 .

[19]  U. Nannmark,et al.  In vivo gene expression in response to anodically oxidized versus machined titanium implants. , 2009, Journal of biomedical materials research. Part A.

[20]  R. Brånemark,et al.  Technique for preparation and characterization in cross-section of oral titanium implant surfaces using focused ion beam and transmission electron microscopy. , 2008, Journal of biomedical materials research. Part A.

[21]  T Albrektsson,et al.  Suggested guidelines for the topographic evaluation of implant surfaces. , 2000, The International journal of oral & maxillofacial implants.

[22]  Ann Wennerberg,et al.  Oral implant surfaces: Part 1--review focusing on topographic and chemical properties of different surfaces and in vivo responses to them. , 2004, The International journal of prosthodontics.

[23]  S. Ichinose,et al.  TEM observation of seven retrieved total knee joints made of Co-Cr-Mo and Ti-Al-V alloys. , 2003, Bio-medical materials and engineering.

[24]  O. Harrysson,et al.  Direct metal fabrication of titanium implants with tailored materials and mechanical properties using electron beam melting technology , 2008 .

[25]  Robert F. Singer,et al.  Selective Electron Beam Melting of Cellular Titanium: Mechanical Properties , 2008 .

[26]  Rickard Brånemark,et al.  Biomechanical, histological, and ultrastructural analyses of laser micro- and nano-structured titanium alloy implants: a study in rabbit. , 2009, Journal of biomedical materials research. Part A.

[27]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[28]  R. Singer,et al.  Auxetic cellular structures through selective electron‐beam melting , 2010 .

[29]  Ola L. A. Harrysson,et al.  Evaluation of titanium implant components directly fabricated through electron beam melting technology , 2006 .

[30]  Victoria Franke Stenport,et al.  Evaluations of bone tissue integration to pure and alloyed titanium implants. , 2008, Clinical implant dentistry and related research.

[31]  Emeka Nkenke,et al.  In vivo performance of selective electron beam-melted Ti-6Al-4V structures. , 2010, Journal of biomedical materials research. Part A.

[32]  Buddy D. Ratner,et al.  Biomaterials with tightly controlled pore size that promote vascular in-growth , 2004 .

[33]  K. Donath,et al.  A method for the study of undecalcified bones and teeth with attached soft tissues. The Säge-Schliff (sawing and grinding) technique. , 1982, Journal of oral pathology.

[34]  Wojciech Swieszkowski,et al.  Highly porous titanium scaffolds for orthopaedic applications. , 2010, Journal of biomedical materials research. Part B, Applied biomaterials.

[35]  S. Lugowski,et al.  Release of metal ions from dental implant materials in vivo: determination of Al, Co, Cr, Mo, Ni, V, and Ti in organ tissue. , 1991, Journal of biomedical materials research.

[36]  C. Gay-Escoda,et al.  Ion implantation: surface treatment for improving the bone integration of titanium and Ti6Al4V dental implants. , 2003, Clinical oral implants research.

[37]  Y. Carvalho,et al.  Evaluation of bone ingrowth into porous titanium implant: histomorphometric analysis in rabbits. , 2010, Brazilian oral research.

[38]  J. Olerud,et al.  Epidermal and dermal integration into sphere-templated porous poly(2-hydroxyethyl methacrylate) implants in mice. , 2010, Journal of biomedical materials research. Part A.

[39]  Buddy D Ratner,et al.  A model for studying epithelial attachment and morphology at the interface between skin and percutaneous devices. , 2005, Journal of biomedical materials research. Part A.

[40]  A. Cometa,et al.  Human adipose-derived stem cells (hASCs) proliferate and differentiate in osteoblast-like cells on trabecular titanium scaffolds. , 2010, Journal of biomedical materials research. Part A.

[41]  Shivakumar Raman,et al.  Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM). , 2010, Journal of the mechanical behavior of biomedical materials.

[42]  R. Listrom,et al.  Interface between titanium 6,4 alloy implants and bone. , 1987, International journal of oral and maxillofacial surgery.

[43]  E. Saino,et al.  Stem Cells Grown in Osteogenic Medium on PLGA, PLGA/HA, and Titanium Scaffolds for Surgical Applications , 2010, Bioinorganic chemistry and applications.