Initial study of the optical spectrum of the ISIS H- ion source plasma.
暂无分享,去创建一个
The front end test stand is being constructed at the Rutherford Appleton Laboratory, with the aim of producing a 60 mA, 2 ms, 50 Hz, perfectly chopped H(-) ion beam. To meet the beam requirements, a more detailed understanding of the ion source plasma is required. To this end, an initial study is made of the optical spectrum of the plasma using a digital spectrometer. The atomic and molecular emission lines of hydrogen and caesium are clearly distinguished and a quantitative comparison is made when the ion source is run in different conditions. The electron temperature is 0.6 eV and measured line widths vary by up to 75%.
[1] S. Lawrie,et al. Latest Results from the Front End Test Stand High Performance H− Ion Source at RAL , 2011 .
[2] J. Pozimski,et al. Redesign of the Analysing Magnet in the ISIS H− Penning Ion Source , 2009 .
[3] Maher I. Boulos,et al. Thermal Plasmas: Fundamentals and Applications , 1994 .
[4] R. Keller,et al. Spectroscopic Measurements on an H- Ion Source Discharge , 1985, IEEE Transactions on Nuclear Science.