Hybrid ground-source heat pump systems for cooling-dominated applications: Experimental and numerical case-study of cooling for cellular tower shelters

Abstract Techno-economic performance of hybrid ground-source (geothermal) heat pump systems for cooling-dominated applications has been investigated. An experimental hybrid ground-source heat pump system, providing an average cooling load of 11 kWth for a cellular tower shelter in Varna, New York, United States (“Varna Site”), was commissioned in 2014 and has been extensively monitored. An air-economizer and dry-fluid cooler provide supplemental heat rejection and limit thermal imbalance in the subsurface. Measurements and analysis showed that over its first two years of operation, the average total system coefficient of performance was 4.8. Various hybrid and non-hybrid ground-source and air-source heat pump configurations have been studied using TRNSYS, calibrated with data measured at the Varna Site. Simulations indicate that for the Varna Site weather and operational conditions, ground-source heat pump-based systems allow the owner to save up to 30% of lifetime electricity consumption in comparison with air-source heat pump-based systems. However, air-source heat pump-based systems can have up to 10% lower total cost of ownership, mainly because of lower upfront capital costs. In the base-case scenario, the hybrid configuration of ground-source heat pump with air-economizer has the lowest lifetime energy consumption of 222 MWhe; the hybrid configuration of air-source heat pump with air-economizer has the lowest lifetime total cost of ownership of $54,000.

[1]  Wei Xu,et al.  Feasibility and performance study of the hybrid ground-source heat pump system for one office building in Chinese heating dominated areas , 2017 .

[2]  Andrew Chiasson Simulation and design of hybrid geothermal heat pump systems , 2007 .

[3]  G. Hellström Ground heat storage : thermal analyses of duct storage systems , 1991 .

[4]  Pingfang Hu,et al.  Study on intermittent operation strategies of a hybrid ground-source heat pump system with double-cooling towers for hotel buildings , 2014 .

[5]  J. Combs,et al.  Thermal conductivity measurement and prediction from geophysical well log parameters with borehole application , 1976 .

[6]  Ioan Sarbu,et al.  General review of ground-source heat pump systems for heating and cooling of buildings , 2014 .

[7]  Z. Fang,et al.  Heat transfer in ground heat exchangers with groundwater advection , 2004 .

[8]  H.-J. G. Diersch,et al.  Transient 3D analysis of borehole heat exchanger modeling , 2011 .

[9]  C. D. Rakopoulos,et al.  Cooling dominated Hybrid Ground Source Heat Pump System application , 2012 .

[10]  J. Desmedt,et al.  Improving the energy efficiency of ground-source heat pump systems in heating dominated school buildings: A case study in Belgium , 2017 .

[11]  Maciej Z. Lukawski,et al.  Hybrid geothermal heat pumps for cooling telecommunications data centers , 2019, Energy and Buildings.

[12]  Hikmet Esen,et al.  Optimization of operating parameters of a ground coupled heat pump system by Taguchi method , 2015 .

[13]  K. Beckers Low-Temperature Geothermal Energy: Systems Modeling, Reservoir Simulation, And Economic Analysis , 2016 .

[14]  Mukesh Pandey,et al.  Hybrid ground coupled heat exchanger systems for space heating/cooling applications: A review , 2016 .

[15]  Yan Gao,et al.  Thermal performance and operation strategy optimization for a practical hybrid ground-source heat-pump system , 2014 .

[16]  Wenzhi Cui,et al.  Optimization of design and operation parameters for hybrid ground-source heat pump assisted with cooling tower , 2015 .

[17]  K. Murugesan,et al.  Experimental study of solar energy storage and space heating using solar assisted ground source heat pump system for Indian climatic conditions , 2017 .

[18]  Javier F. Urchueguía,et al.  Optimization of hybrid – ground coupled and air source – heat pump systems in combination with thermal storage , 2010 .

[19]  Brandon LaBrozzi Utilization of Closed Loop Geothermal Heat Pumps at Verizon Wireless Cellular Towers , 2010 .

[20]  Hiep V. Nguyen,et al.  A methodology and computerized approach for optimizing hybrid ground source heat pump system design , 2013 .

[21]  Daehie Hong,et al.  Performance evaluation and modeling of a hybrid cooling system combining a screw water chiller with a ground source heat pump in a building , 2010 .

[22]  Luis Pérez-Lombard,et al.  A new RC and g-function hybrid model to simulate vertical ground heat exchangers , 2015 .

[23]  Huai Li,et al.  Discussion of a combined solar thermal and ground source heat pump system operation strategy for office heating , 2018 .

[24]  Jeffrey D. Spitler,et al.  Thermal response testing for ground source heat pump systems - An historical review , 2015 .

[25]  Qiang Zhang,et al.  Thermodynamic and economic analysis for ground-source heat pump system coupled with borehole free cooling , 2017 .

[26]  J. Tester,et al.  Co-Generation Opportunities for Lower Grade Geothermal Resources in the Northeast - A Case Study of the Cornell Site in Ithaca, NY , 2010 .

[27]  Wenzhi Cui,et al.  Feasibility study on two schemes for alleviating the underground heat accumulation of the ground source heat pump , 2016 .

[28]  Alessandro Casasso,et al.  Sensitivity Analysis on the Performance of a Ground Source Heat Pump Equipped with a Double U-pipe Borehole Heat Exchanger☆ , 2014 .