Hemodynamics in a compliant hydraulic in vitro model of straight versus tapered PTFE arteriovenous graft.

BACKGROUND Hemodialysis patients require a vascular access to deliver sufficient blood flow to the artificial kidney. Of these vascular accesses, 30% are prosthetic (mainly polytetrafluorethylene [PTFE]) graft implants. These grafts are prone to the development of stenosis in the vein due to intimal hyperplasia, subsequently leading to thrombosis and graft failure. AIM We investigated the hemodynamics in a straight and a tapered PTFE-graft and compare the hydrodynamical behavior of both grafts. MATERIALS AND METHODS Two different vascular access geometry models were examined: a 6-mm diameter straight graft and a 4- to 7-mm tapered graft. The grafts were sutured to a compliant silicon model of an artery and vein in a loop configuration. Flow rate varied between 500 and 1500 mL/min. Two conditions were tested: 1). control: mean pressure is 100 mm Hg at the arterial inlet; and 2). low resistance condition: pressure is 20 mm Hg at the venous outlet. Pulse pressure is 60 mm Hg at the arterial inlet for both conditions. Pressure and flow velocity are measured continuously, while flow rate is measured volumetrically. RESULTS The pressure drop at the arterial anastomosis of the tapered graft is three times higher compared to the straight graft model. Intragraft pressure drops are similar in both graft types. Mean pressure and pulse pressure in the graft and vein are decreased in the low resistance condition. Also, the difference between maximum and minimum velocity is smaller in this. CONCLUSIONS No significant differences are noted between the graft geometries: pressure drop over the graft is almost equal. The major difference is the higher pressure drop at the arterial anastomosis of the tapered graft.

[1]  R. Planken,et al.  Evaluation of 4-mm to 7-mm versus 6-mm prosthetic brachial-antecubital forearm loop access for hemodialysis: results of a randomized multicenter clinical trial. , 2003, Journal of vascular surgery.

[2]  C Kleinstreuer,et al.  Computational haemodynamics analysis and comparison study of arterio-venous grafts. , 2000, Journal of medical engineering & technology.

[3]  A P Hoeks,et al.  Anastomotic intimal hyperplasia in prosthetic arteriovenous fistulas for hemodialysis is associated with initial high flow velocity and not with mismatch in elastic properties. , 1995, Journal of the American Society of Nephrology : JASN.

[4]  M. Stegall,et al.  Preliminary experience with a cuffed ePTFE graft for hemodialysis vascular access. , 2000 .

[5]  K. Rigg COMPLICATIONS OF VASCULAR ACCESS , 2001 .

[6]  A. Leuprecht,et al.  Numerical study of hemodynamics and wall mechanics in distal end-to-side anastomoses of bypass grafts. , 2002, Journal of biomechanics.

[7]  A P Hoeks,et al.  Mismatch in elastic properties around anastomoses of interposition grafts for hemodialysis access. , 1994, Journal of the American Society of Nephrology : JASN.

[8]  T V How,et al.  Sites of stenosis in AV fistulae for haemodialysis access. , 1999, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[9]  H. Y. Liang,et al.  A numerical simulation of steady flow fields in a bypass tube. , 2001, Journal of biomechanics.

[10]  R. Schwartz,et al.  Graft geometry and venous intimal-medial hyperplasia in arteriovenous loop grafts. , 1990, Journal of vascular surgery.

[11]  J. Akoh,et al.  Dialysis Access: Current Practice , 2001 .

[12]  C. L. Mesh,et al.  Improving longevity of prosthetic dialysis grafts in patients with disadvantaged venous outflow. , 2000, Journal of vascular surgery.

[13]  A. Banes,et al.  Mechanical stress stimulates aortic endothelial cells to proliferate. , 1987, Journal of vascular surgery.

[14]  Pascal Verdonck,et al.  Principles of vascular physiology , 2002 .

[15]  H. Scholz,et al.  Comparison of two different arteriovenous anastomotic forms by numerical 3D simulation of blood flow , 2000, The International journal of angiology : official publication of the International College of Angiology, Inc.

[16]  Acute effects of haemodialysis on endothelial function and large artery elasticity. , 2001, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[17]  P. Verdonck,et al.  Computer-controlledin vitro model of the human left heart , 1992, Medical and Biological Engineering and Computing.

[18]  C. Butler,et al.  Hemodialysis Access Part B — Permanent , 1996 .

[19]  P. Verdonck,et al.  Hemodynamic Comparison of Two Different Pediatric Aortic Cannulas , 2002, The International journal of artificial organs.

[20]  H. Udaykumar,et al.  Application of large-eddy simulation to the study of pulsatile flow in a modeled arterial stenosis. , 2001, Journal of biomechanical engineering.