Automated Metabolic Gas Analysis Systems

The use of automated metabolic gas analysis systems or metabolic measurement carts (MMC) in exercise studies is common throughout the industrialised world. They have become essential tools for diagnosing many hospital patients, especially those with cardiorespiratory disease. Moreover, the measurement of maximal oxygen uptake (.VO2max) is routine for many athletes in fitness laboratories and has become a de facto standard in spite of its limitations. The development of metabolic carts has also facilitated the noninvasive determination of the lactate threshold and cardiac output, respiratory gas exchange kinetics, as well as studies of outdoor activities via small portable systems that often use telemetry. Although the fundamental principles behind the measurement of oxygen uptake (.VO2) and carbon dioxide production (.VCO2) have not changed, the techniques used have, and indeed, some have almost turned through a full circle.Early scientists often employed a manual Douglas bag method together with separate chemical analyses, but the need for faster and more efficient techniques fuelled the development of semi- and full-automated systems by private and commercial institutions. Yet, recently some scientists are returning back to the traditional Douglas bag or Tissot-spirometer methods, or are using less complex automated systems to not only save capital costs, but also to have greater control over the measurement process. Over the last 40 years, a considerable number of automated systems have been developed, with over a dozen commercial manufacturers producing in excess of 20 different automated systems. The validity and reliability of all these different systems is not well known, with relatively few independent studies having been published in this area.For comparative studies to be possible and to facilitate greater consistency of measurements in test-retest or longitudinal studies of individuals, further knowledge about the performance characteristics of these systems is needed. Such information, along with the costs and the common features associated with these systems, may aid physicians and scientists to select a system that is best suited to their requirements and may also improve the quality of these frequently reported physiological measures.

[1]  J H Wilmore,et al.  Reproducibility of cardiovascular, respiratory, and metabolic responses to submaximal exercise: the HERITAGE Family Study. , 1998, Medicine and science in sports and exercise.

[2]  G Atkinson,et al.  Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine , 1998, Sports medicine.

[3]  J. Roitman,et al.  ACSM's Resource Manual for Guidelines for Exercise Testing and Prescription , 1998 .

[4]  H. S. Wolff,et al.  The integrating motor pneumotachograph: a new instrument for the measurement of energy expenditure by indirect calorimetry. , 1958, Quarterly journal of experimental physiology and cognate medical sciences.

[5]  T D Noakes,et al.  Implications of exercise testing for prediction of athletic performance: a contemporary perspective. , 1988, Medicine and science in sports and exercise.

[6]  Wim H. M. Saris,et al.  Measuring Physical Activity and Energy Expenditure , 1996 .

[7]  David R. Bassett,et al.  Validation Of The Cosmed K4b2 Portable Metabolic Measurement System , 2001 .

[8]  R. Zeballos,et al.  Behind the scenes of cardiopulmonary exercise testing. , 1994, Clinics in chest medicine.

[9]  J. E. Hansen,et al.  Principles of Exercise Testing and Interpretation , 1994 .

[10]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[11]  N. Jones Clinical Exercise Testing , 1982 .

[12]  Andrew S. Jackson,et al.  AN EVALUATION OF AN AUTOMATED SYSTEM FOR MEASUREMENT OF CARDIORESPIRATORY FUNCTION DURING EXERCISE , 1983 .

[13]  D R Bassett,et al.  Limiting factors for maximum oxygen uptake and determinants of endurance performance. , 2000, Medicine and science in sports and exercise.

[14]  B E Ainsworth,et al.  Validation of the COSMED K4 b2 Portable Metabolic System , 2001, International journal of sports medicine.

[15]  A X Bigard,et al.  Evaluation of the Cosmed K2 telemetry system during exercise at moderate altitude. , 1995, Medicine and science in sports and exercise.

[16]  J H Wilmore,et al.  An automated system for assessing metabolic and respiratory function during exercise. , 1976, Journal of applied physiology.

[17]  V B Unnithan,et al.  Validation of the sensormedics (S2900Z) metabolic cart for pediatric exercise testing. , 1994, Canadian journal of applied physiology = Revue canadienne de physiologie appliquee.

[18]  C. Hausswirth,et al.  The Cosmed K4 Telemetry System as an Accurate Device for Oxygen Uptake Measurements during Exercise , 1997, International journal of sports medicine.

[19]  A Marko,et al.  A new, miniaturized, multichannel, personal radiotelemetry system. , 1968, Journal of applied physiology.

[20]  V. Froelicher,et al.  Effect of sampling on variability and plateau in oxygen uptake. , 1990, Journal of applied physiology.

[21]  C Peel,et al.  Oxygen consumption using the K2 telemetry system and a metabolic cart. , 1993, Medicine and science in sports and exercise.

[22]  V Louhevaara,et al.  Comparison of three field methods for measuring oxygen consumption. , 1985, Ergonomics.

[23]  Mikael Fogelholm,et al.  THE COMPARISON BETWEEN THREE DIFFERENT RESPIRATORY GAS-ANALYSERS , 1999 .

[24]  P S Freedson,et al.  Reliability and validity of a portable metabolic measurement system. , 1996, Canadian journal of applied physiology = Revue canadienne de physiologie appliquee.

[25]  P G Versteeg,et al.  Automated Systems for Measurement of Oxygen Uptake During Exercise Testing , 1989, International journal of sports medicine.

[26]  W G Hopkins,et al.  Design and analysis of research on sport performance enhancement. , 1999, Medicine and science in sports and exercise.

[27]  W L Beaver,et al.  Improved detection of lactate threshold during exercise using a log-log transformation. , 1985, Journal of applied physiology.

[28]  D A Sainsbury,et al.  An on-line microcomputer program for the monitoring of physiological variables during rest and exercise. , 1988, Computers in biology and medicine.

[29]  A Huszczuk,et al.  A respiratory gas exchange simulator for routine calibration in metabolic studies. , 1990, The European respiratory journal.

[30]  D. Heil,et al.  The Pressor Response to Submaximal Cycle Ergometry While Using Aerodynamic Handlebars , 1997, International journal of sports medicine.

[31]  K. Beck,et al.  Delay time adjustments to minimize errors in breath-by-breath measurement of Vo2 during exercise. , 1996, Journal of applied physiology.

[32]  A Geyssant,et al.  Validity of oxygen uptake measurements during exercise under moderate hyperoxia. , 1998, Medicine and science in sports and exercise.

[33]  B. Whipp,et al.  On-line computer analysis and breath-by-breath graphical display of exercise function tests. , 1973, Journal of applied physiology.

[34]  B. A. Bush,et al.  Microprocessor exercise physiology systems vs a nonautomated system. A comparison of data output. , 1987, Chest.

[35]  C J Gore,et al.  Automated VO2max calibrator for open-circuit indirect calorimetry systems. , 1997, Medicine and science in sports and exercise.

[36]  J T Kearney,et al.  Validity and Reliability of the Cosmed K2 Instrument , 1993, International journal of sports medicine.

[37]  B R Londeree,et al.  The Use of Laboratory Test Results with Long Distance Runners , 1986, Sports medicine.

[38]  Will G. Hopkins,et al.  Measures of Reliability in Sports Medicine and Science: Correspondence , 2000 .

[39]  A. Dirix,et al.  The Olympic Book of Sports Medicine , 1991 .

[40]  R. Fagard,et al.  Comparison of cardiac output measured by two automated methods of CO2 rebreathing. , 2000, Medicine and science in sports and exercise.

[41]  T. Verde,et al.  Four commonly utilized metabolic systems fail to produce similar results during submaximal and maximal exercise , 1994 .

[42]  T. Reybrouck,et al.  Evaluation of breath-by-breath measurement of respiratory gas exchange in pediatric exercise testing. , 1992, Chest.

[43]  J. Mitchell,et al.  The physiological meaning of the maximal oxygen intake test. , 1958, The Journal of clinical investigation.

[44]  R M Gardner,et al.  Turbine flowmeter vs. Fleisch pneumotachometer: a comparative study for exercise testing. , 1987, Journal of applied physiology.

[45]  D R Bassett,et al.  Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system. , 2001, Journal of applied physiology.

[46]  S. Horvath,et al.  Validation of open-circuit method for the determination of oxygen consumption. , 1973, Journal of applied physiology.

[47]  H. Benoit,et al.  A system to simulate gas exchange in humans to control quality of metabolic measurements , 1998, European Journal of Applied Physiology and Occupational Physiology.

[48]  J W. Yates,et al.  THE VALIDATION OF A METABOLIC CART WITHOUT HUMAN SUBJECTS , 2001 .

[49]  P. F. Scholander Analyzer for accurate estimation of respiratory gases in one-half cubic centimeter samples. , 1947, The Journal of biological chemistry.

[50]  R. E. Johnson,et al.  A versatile system for measuring oxygen consumption in man. , 1967, Journal of applied physiology.

[51]  J. Sutton,et al.  VO2max--new concepts on an old theme. , 1992, Medicine and science in sports and exercise.

[52]  B E Ainsworth,et al.  Validation of Aerosport KB1-C portable metabolic system. , 1999, International journal of sports medicine.

[53]  J Daniels Portable respiratory gas collection equipment. , 1971, Journal of applied physiology.

[54]  K. Wasserman,et al.  Evaluation of a symmetrically disposed Pitot tube flowmeter for measuring gas flow during exercise. , 1994, Journal of applied physiology.

[55]  D. Rosenthal,et al.  Clinical exercise testing, 3rd ed , 1988 .

[56]  John L. Hankinson,et al.  Standardization of Spirometry, 1994 Update. American Thoracic Society. , 1995, American journal of respiratory and critical care medicine.

[57]  J. Pivarnik,et al.  The reliability of aerobic capacity (VO2max) testing in adolescent girls. , 1996, Research quarterly for exercise and sport.

[58]  A HENSCHEL,et al.  Maximal oxygen intake as an objective measure of cardio-respiratory performance. , 1955, Journal of applied physiology.

[59]  E. Howley,et al.  Criteria for maximal oxygen uptake: review and commentary. , 1995, Medicine and science in sports and exercise.

[60]  J. Macdougall,et al.  Physiological testing of the high-performance athlete , 1993 .

[61]  N L Jones,et al.  Quality control of exercise test measurements. , 1979, Medicine and science in sports.

[62]  Kenneth R. Turley,et al.  Maximal Treadmill Versus Cycle Ergometry Testing in Children: Differences, Reliability, and Variability of Responses , 1995 .

[63]  Lawrence E. Armstrong,et al.  Variability of Respiration and Metabolism: Responses to Submaximal Cycling and Running , 1985 .

[64]  D M Selkowitz,et al.  High frequency electrical stimulation in muscle strengthening , 1989, The American journal of sports medicine.

[65]  V. Katch,et al.  Reliability and Within Subject Variability of V̇E, V̇O2, Heart Rate and Blood Pressure During Submaximum Cycle Ergometry , 1993, International journal of sports medicine.

[66]  T. Ienna,et al.  51 COMPARISON OF A PORTABLE TELEMETRIC OXYGEN ANALYZER WITH THE MEDICAL GRAPHICS 2001 EXERCISE SYSTEM , 1993 .

[67]  G. Ruppel Manual of Pulmonary Function Testing , 1987 .

[68]  C. Consolazio,et al.  Physiological Measurements of Metabolic Functions in Man , 1963 .

[69]  J S Janicki,et al.  Long-term reproducibility of respiratory gas exchange measurements during exercise in patients with stable cardiac failure. , 1990, Chest.

[70]  C S Garrard,et al.  The reproducibility of the respiratory responses to maximum exercise. , 1986, Respiration; international review of thoracic diseases.

[71]  J. Durnin,et al.  CHANGES IN CONCENTRATION OF GASES IN THE RUBBER BLADDERS OF MAX-PLANCK RESPIROMETERS. , 1964, Journal of applied physiology.

[72]  Carl Foster,et al.  Physiological Assessment of Human Fitness , 1995 .

[73]  M. Farrally,et al.  Validity and reliability of the Cosmed K2 to measure oxygen uptake. , 1993, Canadian journal of applied physiology = Revue canadienne de physiologie appliquee.

[74]  J E Cochrane,et al.  Alignment of ventilation and gas fraction for breath-by-breath respiratory gas exchange calculations in exercise. , 1991, Computers and biomedical research, an international journal.

[75]  J H Wilmore,et al.  Reproducibility of maximal exercise test data in the HERITAGE family study. , 1999, Medicine and science in sports and exercise.

[76]  L Stangeland,et al.  Respiratory gas exchange during treadmill exercise testing: reproducibility and comparison of different exercise protocols. , 1991, Scandinavian journal of clinical and laboratory investigation.

[77]  Dj Macfarlane Who do exercise physiologists test best - athletes or themselves , 1991 .

[78]  G. Balady,et al.  ACSM/AHA JOINT POSITION STATEMENT , 1999 .

[79]  G S Pechar,et al.  Comparison of continuous and discontinuous treadmill and bicycle tests for max Vo2. , 1973, Medicine and science in sports.

[80]  E. Leslie Chusid,et al.  PULMONARY FUNCTION TESTING GUIDELINES AND CONTROVERSIES , 1984 .

[81]  P B Raven,et al.  Evaluation of the Cosmed K2 portable telemetric oxygen uptake analyzer. , 1992, Medicine and science in sports and exercise.

[82]  H Heck,et al.  The Validity of the Telemetric System CORTEX X1 in the Ventilatory and Gas Exchange Measurement during Exercise , 1997, International journal of sports medicine.

[83]  S. Strømme,et al.  Assessment of maximal aerobic power in specifically trained athletes. , 1977, Journal of applied physiology: respiratory, environmental and exercise physiology.

[84]  P. Åstrand,et al.  Textbook of Work Physiology , 1970 .

[85]  L L Smith,et al.  Cytokine hypothesis of overtraining: a physiological adaptation to excessive stress? , 2000, Medicine and science in sports and exercise.

[86]  W G Hopkins,et al.  Measures of Reliability in Sports Medicine and Science , 2000, Sports medicine.

[87]  H. Welch,et al.  Measurement of metabolic rate in hyperoxia. , 1981, Journal of applied physiology: respiratory, environmental and exercise physiology.

[88]  A V Hill,et al.  The position occupied by the production of heat, in the chain of processes constituting a muscular contraction , 1911, The Journal of physiology.

[89]  R. Hughson,et al.  Field testing of VO2peak in cross-country skiers with portable breath-by-breath system. , 2001, Canadian journal of applied physiology = Revue canadienne de physiologie appliquee.

[90]  Kissen At,et al.  New approach for on-line, continuous determination of oxygen consumption in human subjects. , 1967 .

[91]  R M Gardner,et al.  Performance evaluation of contemporary spirometers. , 1990, Chest.

[92]  S V Dawson,et al.  Linearity and frequency response of pneumotachographs. , 1972, Journal of applied physiology.

[93]  J Grønlund,et al.  A modified photo- and magnetoacoustic multigas analyzer applied in gas exchange measurements. , 1994, Journal of applied physiology.

[94]  J. Smith,et al.  Critical Power is Related to Cycling Time Trial Performance , 1999, International journal of sports medicine.

[95]  J. E. Engebretson VALIDITY OF A BREATH-BY-BREATH GAS EXCHANGE ANALYSIS SYSTEM , 1998 .

[96]  D. J. Cunningham,et al.  Claude Gordon Douglas, 1882-1963 , 1964, Biographical Memoirs of Fellows of the Royal Society.

[97]  H. Kuipers,et al.  Validation of a Computerized Metabolic Measurement System (Oxycon-Pro®) During Low and High Intensity Exercise1 , 2001, International journal of sports medicine.

[98]  V L Katch,et al.  Biological variability in maximum aerobic power. , 1982, Medicine and science in sports and exercise.

[99]  C. V. Taylor SOME PROPERTIES OF MAXIMAL AND SUBMAXIMAL EXERCISE WITH REFERENCE TO PHYSIOLOGICAL VARIATION AND THE MEASUREMENT OF EXERCISE TOLERANCE , 1944 .

[100]  R J Shephard,et al.  Tests of Maximum Oxygen Intake A Critical Review , 1984, Sports medicine.

[101]  S Miodownik,et al.  System of automated gas-exchange analysis for the investigation of metabolic processes. , 2000, Journal of applied physiology.

[102]  Hart Jd,et al.  The calibration of gas volume measuring devices at continuous and pulsatile flows. , 1996 .

[103]  Cureton Tk Interpretation of the oxygen intake test. What is it , 1973 .

[104]  M H Harrison,et al.  The 'Oxylog': an evaluation. , 1982, Ergonomics.

[105]  Walter R. Frontera,et al.  Reliability of VO2max in Adolescent Runners: A Comparison Between Plateau Achievers and Nonachievers , 1995 .

[106]  G Atkinson,et al.  Typical Error Versus Limits of Agreement , 2000, Sports medicine.

[107]  S A Ward,et al.  Physiological determinants of pulmonary gas exchange kinetics during exercise. , 1990, Medicine and science in sports and exercise.

[108]  T D Noakes,et al.  Maximal oxygen uptake: "classical" versus "contemporary" viewpoints: a rebuttal. , 1998, Medicine and science in sports and exercise.

[109]  R. Edwards,et al.  A new technique for recording respiratory transients at the start of exercise. , 1974, Respiration physiology.

[110]  G. Gaesser,et al.  Assessment of the aerosport TEEM 100 portable metabolic measurement system. , 1996, Medicine and science in sports and exercise.

[111]  E. Russi,et al.  Effect of training on repeatability of cardiopulmonary exercise performance in normal men and women. , 1997, Medicine and science in sports and exercise.

[112]  W L Beaver,et al.  Water vapor corrections in oxygen consumption calculations. , 1973, Journal of applied physiology.

[113]  N L Jones,et al.  Evaluation of a microprocessor-controlled exercise testing system. , 1984, Journal of applied physiology: respiratory, environmental and exercise physiology.

[114]  Luc Léger,et al.  Variability of Maximum Oxygen Consumption Measurement in Various Metabolic Systems , 1999 .

[115]  M C Lancaster,et al.  A comparison of the reproducibility and physiologic response to three maximal treadmill exercise protocols. , 1974, Chest.

[116]  J. Durnin,et al.  Energy, work and leisure. , 1967 .

[117]  M. Whaley,et al.  INTER-LABORATORY RELIABILITY OF VO2MAX AND SUBMAXIMAL MEASUREMENTS87 , 1996 .

[118]  J H Wilmore,et al.  Semiautomated systems approach to the assessment of oxygen uptake during exercise. , 1974, Journal of applied physiology.

[119]  J. Timmons,et al.  Reproducibility of cardiorespiratory measurements during submaximal and maximal running in children. , 1993, British journal of sports medicine.

[120]  R. Shephard,et al.  A critical examination of the Douglas bag technique * , 1955, The Journal of physiology.