Possibilities Concerning Diagnosis of the SSP-FK Aircraft Fire Suppression System in Terms of Determination of Reasons for False Fire Alarms / Możliwości Diagnozowania Lotniczego Systemu Przeciwpożarowego SSP-FK w Aspekcie Określania Przyczyn Fałszywego Sygnalizowania Pożaru

Abstract The paper presents selected results of work at the Air Force Institute of Technology (AFIT) in the scope of testing of the SSP-FK fire suppression system used on many types of military aircraft operating in the Polish Armed Forces. For the purpose of determining conditions for false fire alarms, SSP-FK simulation models have been developed. The study was carried out on simulation models in Matlab-Simulink and Circuit-Maker packages. Results of this work have been used for diagnosis of the SSP-FK system during a test of real cases of false activation of these devices. Streszczenie W artykule przedstawiono wybrane wyniki prac realizowanych w Instytucie Technicznym Wojsk Lotniczych (ITWL) w zakresie badań instalacji przeciwpożarowej SSP-FK stosowanej na wielu typach wojskowych statków powietrznych eksploatowanych w Siłach Zbrojnych RP. Dla określania warunków fałszywego sygnalizowania pożaru opracowano modele symulacyjne działania bloków wykonawczych SSP-FK. Badania modeli symulacyjnych wykonano w pakietach obliczeniowych Matlab-Simulink i Circuit-Maker. Wyniki tych prac zostały wykorzystane do diagnostyki instalacji SSP-FK w trakcie badania rzeczywistych przypadków fałszywego zadziałania tych urządzeń.