LVD micromirror for rapid reference scanning in optical coherence tomography

A translationally-scanning mirror is always desired for the axial scanning in optical coherence tomography (OCT), but conventional scanners are bulky and have relatively slow scanning speed. This paper reports a micromirror that has the potential to achieve both the scanning speed and range required by OCT. The large piston motion of the micromirror is obtained using a large-vertical-displacement (LVD) microactuator. The device is fabricated using a deep-reactive-ion-etch (DRIE) CMOS-MEMS process. A pair of electrothermal bimorph actuators is employed to achieve tilt-free mirror plate and large piston motion. A linear voltage divider with a voltage ratio of 1:2.3 between the two electrothermal actuators has been used to obtain static displacements up to 200 &mgr;m. The frequency response of this device was obtained using a laser Doppler vibrometer, and resonant peaks were observed at 1.18 and 2.62 kHz. AC signals at 50 Hz with a voltage ratio of 1:1.2 were supplied to the actuators, and the maximum dynamic piston motion was measured to be 26 &mgr;m. The decreasing amplitude over increasing frequency was caused by the heat-sink effect of the mirror plate. A phase delay between the two actuators was also observed.

[1]  Ming C. Wu,et al.  High-resolution 3D OCT imaging with a MEMS scanning endoscope , 2005, SPIE MOEMS-MEMS.

[2]  S Yazdanfar,et al.  Electrostatic micromachine scanning mirror for optical coherence tomography. , 2003, Optics letters.

[3]  Kevin Barraclough,et al.  I and i , 2001, BMJ : British Medical Journal.

[4]  J. Fujimoto,et al.  High resolution imaging of the upper respiratory tract with optical coherence tomography: a feasibility study. , 1998, American journal of respiratory and critical care medicine.

[5]  G. Fedder,et al.  A two-axis electrothermal micromirror for endoscopic optical coherence tomography , 2004, IEEE Journal of Selected Topics in Quantum Electronics.

[6]  Huikai Xie,et al.  A thermal bimorph micromirror with large bi-directional and vertical actuation , 2005 .

[7]  Gary K. Fedder,et al.  Endoscopic optical coherence tomographic imaging with a CMOS-MEMS micromirror $ , 2003 .

[8]  I. Alex Vitkin,et al.  Dynamic focus control in high-speed optical coherence tomography based on a microelectromechanical mirror , 2004 .

[9]  Woonggyu Jung,et al.  3D MEMS based minimally invasive optical coherence tomography , 2005, The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05..

[10]  Zhongping Chen,et al.  Real-time phase-resolved optical coherence tomography and optical Doppler tomography. , 2002, Optics Express.

[11]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[12]  J M Schmitt,et al.  Subsurface imaging of living skin with optical coherence microscopy. , 1995, Dermatology.

[13]  Zhihua Ding,et al.  High-resolution optical coherence tomography over a large depth range with an axicon lens. , 2002, Optics letters.

[14]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[16]  Andrew A. Goldenberg,et al.  Micromachined 2-D scanner for 3-D optical coherence tomography , 2005 .

[17]  Andrew M. Rollins,et al.  Reference Optical Delay Scanning , 2001 .

[18]  J. Nelson,et al.  High-speed fiber based polarization-sensitive optical coherence tomography of in vivo human skin. , 2000, Optics letters.

[19]  J. Fujimoto,et al.  Optical coherence microscopy in scattering media. , 1994, Optics letters.

[20]  J. Fujimoto,et al.  Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging , 1992 .

[21]  Victor X D Yang,et al.  Micromachined array tip for multifocus fiber-based optical coherence tomography. , 2004, Optics letters.

[22]  G. Fedder,et al.  Endoscopic optical coherence tomography based on a microelectromechanical mirror. , 2001, Optics letters.

[23]  J. Fujimoto,et al.  In vivo ultrahigh-resolution optical coherence tomography. , 1999, Optics letters.

[24]  J. Fujimoto,et al.  Spectroscopic optical coherence tomography. , 2000 .

[25]  Matthew Brenner,et al.  In vivo endoscopic optical coherence tomography by use of a rotational microelectromechanical system probe. , 2004, Optics letters.

[26]  J G Fujimoto,et al.  Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography. , 2004, Optics letters.

[27]  J. Izatt,et al.  In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography. , 1997, Optics letters.

[28]  S. Yun,et al.  High-speed spectral-domain optical coherence tomography at 1.3 mum wavelength. , 2003, Optics express.

[29]  Y.C. Chen,et al.  Development of a fast scanning miniature probe and methods of dispersion management for high-resolution optical coherence tomography , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[30]  G. Gelikonov,et al.  In vivo OCT imaging of hard and soft tissue of the oral cavity. , 1998, Optics express.

[31]  J. Fujimoto,et al.  In vivo endoscopic optical biopsy with optical coherence tomography. , 1997, Science.