Numerical model of heat transfer in the human eye with consideration of fluid dynamics of the aqueous humour

In this work we present a new 3D numerical model for heat transfer in the human eye, which takes into account the aqueous humour flow in the anterior chamber. We show that consideration of this phenomenon in the calculations alters the temperature distribution on the corneal and lens surfaces, without, however, noticeably changing their absolute values. The most notable effect is that the coolest area of the cornea moves at a point of 2 mm inferior to its geometric centre. The maximum velocity of the fluid in the anterior chamber was found to be 3.36 × 10(-4) m s(-1). The effect of the flow on displacing the cool area of the corneal surface temperature is counterbalanced by assuming anisotropic thermal conductivity. The model was implemented in the case of an artificial intraocular lens to show the resulting temperature variations.

[1]  L. Tan,et al.  Accuracy and sensitivity of the dynamic ocular thermography and inter-subjects ocular surface temperature (OST) in Chinese young adults. , 2009, Contact lens & anterior eye : the journal of the British Contact Lens Association.

[2]  J J Lagendijk,et al.  A mathematical model to calculate temperature distributions in human and rabbit eyes during hyperthermic treatment. , 1982, Physics in medicine and biology.

[3]  A. Hirata,et al.  Temperature rises in the human eye exposed to EM waves in the frequency range 0.6-6 GHz , 2000 .

[4]  Andres Peratta,et al.  3D low frequency electromagnetic modelling of the human eye with boundary elements: Application to conductive keratoplasty , 2008 .

[5]  E. Y. K. Ng,et al.  A boundary element model of the human eye undergoing laser thermokeratoplasty , 2008, Comput. Biol. Medicine.

[6]  A. Hirata,et al.  Temperature increase in human eyes due to near-field and far-field exposures at 900 MHz, 1.5 GHz, and 1.9 GHz , 2005, IEEE Transactions on Electromagnetic Compatibility.

[7]  James S Wolffsohn,et al.  Ocular Surface Temperature: A Review , 2005, Eye & contact lens.

[8]  B W Raaymakers,et al.  Modelling the impact of blood flow on the temperature distribution in the human eye and the orbit: fixed heat transfer coefficients versus the Pennes bioheat model versus discrete blood vessels , 2006, Physics in medicine and biology.

[9]  Arunn Narasimhan,et al.  Transient simulations of heat transfer in human eye undergoing laser surgery , 2010 .

[10]  E. Y. K. Ng,et al.  Ocular surface temperature: A 3D FEM prediction using bioheat equation , 2007, Comput. Biol. Medicine.

[11]  J. Saiz,et al.  Ring electrode for radio-frequency heating of the cornea: Modelling andin vitro experiments , 2003, Medical and Biological Engineering and Computing.

[12]  Akimasa Hirata Improved Heat Transfer Modeling of the Eye for Electromagnetic Wave Exposures , 2007, IEEE Transactions on Biomedical Engineering.

[13]  V. De Santis,et al.  Prediction of Temperature Increase in Human Eyes Due to RF Sources , 2007, IEEE Transactions on Electromagnetic Compatibility.

[14]  E. Y. K. Ng,et al.  Simulation of aqueous humor hydrodynamics in human eye heat transfer , 2008, Comput. Biol. Medicine.

[15]  A. Taflove,et al.  Computation of the Electromagnetic Fields and Induced Temperatures Within a Model of the Microwave-Irradiated Human Eye , 1975 .

[16]  Alptekin Aksan,et al.  Prediction of the extent of thermal damage in the cornea during conductive keratoplasty , 2010 .

[17]  J. A. Scott The computation of temperature rises in the human eye induced by infrared radiation. , 1988, Physics in medicine and biology.

[18]  James C. Lin,et al.  Effect of 2450-Mhz Radiation on the Rabbit Eye , 1975 .

[19]  E. Y. K. Ng,et al.  FEM simulation of the eye structure with bioheat analysis , 2006, Comput. Methods Programs Biomed..

[20]  Akimasa Hirata,et al.  Calculation of Temperature Rises in the Human Eye Exposed to EM Waves in the ISM Frequency Bands(Special Issue on Recent Progress in Electromagnetic Compatibility Technology) , 2000 .

[21]  H. H. Pennes Analysis of tissue and arterial blood temperatures in the resting human forearm. 1948. , 1948, Journal of applied physiology.

[22]  J. A. Scott,et al.  A finite element model of heat transport in the human eye. , 1988, Physics in medicine and biology.

[23]  J. Doss,et al.  Technique for the selective heating of corneal stroma , 1980 .

[24]  J. Saiz,et al.  Radio-frequency heating of the cornea: theoretical model and in vitro experiments , 2002, IEEE Transactions on Biomedical Engineering.

[25]  Javier Saiz,et al.  Modeling for radio-frequency conductive keratoplasty: implications for the maximum temperature reached in the cornea , 2005, Physiological measurement.

[26]  Jeffrey J. Heys,et al.  A Boussinesq Model of Natural Convection in the Human Eye and the Formation of Krukenberg's Spindle , 2002, Annals of Biomedical Engineering.

[27]  P B Morgan,et al.  Potential Applications of Ocular Thermography , 1993, Optometry and vision science : official publication of the American Academy of Optometry.

[28]  J. Elder,et al.  Ocular effects of radiofrequency energy , 2003, Bioelectromagnetics.

[29]  R Mapstone,et al.  Measurement of corneal temperature. , 1968, Experimental eye research.

[30]  O Fujiwara,et al.  Temperature elevation in the eye of anatomically based human head models for plane-wave exposures , 2007, Physics in medicine and biology.