A two‐step direct method for estimating the seismic response of nonlinear structures equipped with nonlinear viscous dampers

SUMMARY The insertion of fluid viscous dampers in building structures is an innovative technology that can improve significantly the seismic response. These devices could be very useful also in the retrofit of existing buildings. The effect of this typology of damping system is usually identified with an equivalent supplemental damping ratio, which depends on the maximum displacement of the structure, so that iterative procedures are required. In this paper, a simplified direct assessment method for nonlinear structures equipped with nonlinear fluid viscous dampers is proposed. The method proposed in this study is composed by two steps. The first one yields the direct estimate of the supplemental damping ratio provided by nonlinear viscous dampers in presence of a linear elastic structural response. The second step extends the procedure to structures with nonlinear behavior. Both graphical and analytical approaches have been developed. The proposed method has then been verified through several applications and comparisons with nonlinear dynamic analyses. Moreover, an investigation has been performed with regard to the influence of the relations that define the damping reduction factor and the hysteretic damping. Copyright © 2014 John Wiley & Sons, Ltd.

[1]  Anil K. Chopra,et al.  Earthquake response of elastic SDF systems with non‐linear fluid viscous dampers , 2002 .

[2]  Fahim Sadek,et al.  Linear Procedures for Structures with Velocity-Dependent Dampers , 2000 .

[3]  Mahendra P. Singh,et al.  Optimal placement of dampers for passive response control , 2002 .

[4]  Yu-Yuan Lin,et al.  Study on Damping Reduction Factor for Buildings under Earthquake Ground Motions , 2003 .

[5]  Gary F. Dargush,et al.  Analytical Model of Viscoelastic Fluid Dampers , 1993 .

[6]  Michael C. Constantinou,et al.  Seismic response of structures with supplemental damping , 1993 .

[7]  Luca Landi,et al.  A Methodology for the Direct Assessment of the Damping Ratio of Structures Equipped with Nonlinear Viscous Dampers , 2012 .

[8]  Peter Fajfar,et al.  A Nonlinear Analysis Method for Performance-Based Seismic Design , 2000 .

[9]  Jinkook Kim,et al.  Evaluation of equivalent damping ratio of a structure with added dampers , 2004 .

[10]  Tomaso Trombetti,et al.  A Five-Step Procedure for the Dimensioning of Viscous Dampers to Be Inserted in Building Structures , 2010 .

[11]  Gary F. Dargush,et al.  Multi-Objective Evolutionary Seismic Design with Passive Energy Dissipation Systems , 2009 .

[12]  Luca Landi,et al.  On the Design of Viscous Dampers for the Rehabilitation of Plan-Asymmetric Buildings , 2013 .

[13]  M. Constantinou,et al.  Elastic and Inelastic Seismic Response of Buildings with Damping Systems , 2002 .

[14]  Tomaso Trombetti,et al.  Force reduction factor for building structures equipped with added viscous dampers , 2013, Bulletin of Earthquake Engineering.

[15]  Tomaso Trombetti,et al.  On the dimensioning of viscous dampers for the mitigation of the earthquake-induced effects in moment-resisting frame structures , 2013, Bulletin of Earthquake Engineering.

[16]  Luca Landi,et al.  Simplified method for the assessment of the nonlinear seismic response of structures equipped with viscous dampers , 2013 .

[17]  Izuru Takewaki,et al.  Optimal damper placement for minimum transfer functions , 1997 .

[18]  Gary F. Dargush,et al.  DYNAMIC ANALYSIS OF VISCOELASTIC-FLUID DAMPERS , 1995 .

[19]  Kuo-Chun Chang,et al.  Direct displacement-based design for seismic retrofit of existing buildings using nonlinear viscous dampers , 2008 .

[20]  Luca Landi,et al.  A procedure for the direct determination of the required supplemental damping for the seismic retrofit with viscous dampers , 2014 .

[21]  T. T. Soong,et al.  Passive and Active Structural Vibration Control in Civil Engineering , 1994, CISM International Centre for Mechanical Sciences.

[22]  Andrei M. Reinhorn,et al.  Design of Supplemental Dampers for Control of Structures , 1996 .

[23]  Diego Lo´pez Garci´a A Simple Method for the Design of Optimal Damper Configurations in MDOF Structures , 2001 .

[24]  Iunio Iervolino,et al.  REXEL: computer aided record selection for code-based seismic structural analysis , 2010 .

[25]  Mervyn J. Kowalsky,et al.  Equivalent Damping in Support of Direct Displacement-Based Design , 2004 .

[26]  M. Fardis,et al.  Deformations of Reinforced Concrete Members at Yielding and Ultimate , 2001 .