Online oxygen measurements inside a microreactor with modeling of transport phenomena

Oxygen imaging using an epifluorescent microscope was performed inside a microfluidic chip by utilizing nanosensor particles stained with oxygen-sensitive luminescent dye. The oxidation reaction of β-d-glucose to hydrogen peroxide and δ-d-gluconolactone by molecular oxygen in the presence of glucose oxidase from Aspergillus niger inside microreactors with Y-shaped microchannels was followed with this measuring technique. This reaction is widely used in diagnostics and biotechnology. Dissolved oxygen concentrations were measured at various flow rates and microchannel dimensions. Additional batch experiments and microreactor experiments with a reaction-free set-up were conducted. Mathematical models, ranging from a full 3D description of transport phenomena, incorporating convection, diffusion and enzymatic reaction terms along with the parabolic velocity profile, to simplified less precise models were developed to simulate the concentration of dissolved oxygen inside the microchannels, to assess the required model complexity for achieving precise results and to depict the governing transport characteristics at the microscale.

[1]  Polona Žnidaršič-Plazl,et al.  Modelling of laccase-catalyzed l-DOPA oxidation in a microreactor , 2009 .

[2]  Depthwise averaging approach to cross-stream mixing in a pressure-driven microchannel flow , 2005 .

[3]  Visualization and measurement of dissolved oxygen concentrations in hydrodynamic flow focusing , 2009, 2009 IEEE Sensors.

[4]  D. Peričin,et al.  Glucose oxidase from Aspergillus niger: the mechanism of action with molecular oxygen, quinones, and one-electron acceptors. , 2005, The international journal of biochemistry & cell biology.

[5]  P. Cremer,et al.  Generating fixed concentration arrays in a microfluidic device , 2003 .

[6]  Guy Marin,et al.  Multi-zone TAP-reactors theory and application: I. The global transfer matrix equation , 2001 .

[7]  Nam-Trung Nguyen,et al.  Nonlinear diffusive mixing in microchannels: theory and experiments , 2004 .

[8]  Andrei G. Fedorov,et al.  Hydrogen generation in a reverse‐flow microreactor: 1. Model formulation and scaling , 2005 .

[9]  D. J. Porter,et al.  7 Flavoprotein Oxidases , 1975 .

[10]  Alexander Mitsos,et al.  Introduction chapter: Microfabricated Power Generation Devices: Design and Technology , 2009 .

[11]  Polona Žnidaršič-Plazl,et al.  l-Malic acid production within a microreactor with surface immobilised fumarase , 2011 .

[12]  Feliksas Ivanauskas,et al.  Mathematical Modeling of Biosensors: An Introduction for Chemists and Mathematicians , 2009 .

[13]  Mitja Lakner,et al.  Parallel flow of immiscible liquids in a microreactor: modeling and experimental study , 2012 .

[14]  Guy Marin,et al.  Multi-zone TAP-reactors theory and application, II: the three-dimensional theory , 2001 .

[15]  P. Su,et al.  Polyamidoamine dendrimer as a spacer for the immobilization of glucose oxidase in capillary enzyme microreactor. , 2010, Analytical biochemistry.

[16]  Mayuresh V. Kothare,et al.  Modeling of Multicomponent Concentration Profiles in Membrane Microreactors , 2005 .

[17]  G. Jovanovic,et al.  Dechlorination of p-chlorophenol in a microreactor with bimetallic Pd/Fe catalyst , 2005 .

[18]  R. Blaikie,et al.  Spatially Resolved Measurement of Dissolved Oxygen in Multistream Microfluidic Devices , 2010, IEEE Sensors Journal.

[19]  Kyung Chun Kim,et al.  Measurement of dissolved oxygen concentration field in a microchannel using PtOEP/PS film , 2011, J. Vis..

[20]  T. Mukherjee,et al.  Institute of Physics Publishing Journal of Micromechanics and Microengineering Systematic Modeling of Microfluidic Concentration Gradient Generators , 2022 .

[21]  Dionisios G. Vlachos,et al.  Microreactor Modeling for Hydrogen Production from Ammonia Decomposition on Ruthenium , 2004 .

[22]  Ingo Klimant,et al.  Poly(styrene-block-vinylpyrrolidone) beads as a versatile material for simple fabrication of optical nanosensors. , 2008, Analytical chemistry.

[23]  G. Hébrard,et al.  Experimental study of oxygen diffusion coefficients in clean water containing salt, glucose or surfactant: Consequences on the liquid-side mass transfer coefficients , 2010 .

[24]  Jacob N. Chung,et al.  Numerical modeling of hydrogen production from ammonia decomposition for fuel cell applications , 2010 .

[25]  Alexander Mitsos,et al.  Microfabricated Power Generation Devices , 2009 .

[26]  Ingo Klimant,et al.  Microsphere sedimentation arrays for multiplexed bioanalytics , 2006 .

[27]  Norbert Kockmann,et al.  Micro process engineering : fundamentals, devices, fabrication, and applications , 2013 .

[28]  H J Bright,et al.  The oxidation of 1-deuterated glucose by glucose oxidase. , 1967, The Journal of biological chemistry.

[29]  Polona Žnidaršič-Plazl,et al.  Modelling and experimental studies on lipase-catalyzed isoamyl acetate synthesis in a microreactor , 2009 .

[30]  J. Raba,et al.  Glucose Oxidase as an Analytical Reagent , 1995 .

[31]  V MASSEY,et al.  PURIFICATION AND PROPERTIES OF THE GLUCOSE OXIDASE FROM ASPERGILLUS NIGER. , 1965, The Journal of biological chemistry.

[32]  I. Klimant,et al.  Ultrabright oxygen optodes based on cyclometalated iridium(III) coumarin complexes. , 2007, Analytical chemistry.

[33]  Harvey G. Stenger,et al.  Water gas shift reaction kinetics and reactor modeling for fuel cell grade hydrogen , 2003 .

[34]  Dionisios G. Vlachos,et al.  From Density Functional Theory to Microchemical Device Homogenization: Model Prediction of Hydrogen Production For Portable Fuel Cells , 2004 .

[35]  B. Finlayson,et al.  Quantitative analysis of molecular interaction in a microfluidic channel: the T-sensor. , 1999, Analytical chemistry.

[36]  D. Beard Response to “Comment on ‘Taylor dispersion of a solute in a microfluidic channel’ [J. Appl. Phys. 90, 6553 (2001)]” , 2001 .

[37]  I. Klimant,et al.  Luminescent nanobeads for optical sensing and imaging of dissolved oxygen , 2008 .

[38]  Hyung Gyu Park,et al.  Methanol steam reformer on a silicon wafer , 2006, Journal of Microelectromechanical Systems.

[39]  G. Kameia,et al.  The kinetics of reactions between pyrite and O2-bearing water revealed from in situ monitoring of DO, Eh and pH in a closed system , 2000 .

[40]  K. Groebe,et al.  Glucose diffusion coefficients determined from concentration profiles in EMT6 tumor spheroids incubated in radioactively labeled L-glucose. , 1994, Advances in experimental medicine and biology.

[41]  Hongjun Song,et al.  Cross-stream diffusion under pressure-driven flow in microchannels with arbitrary aspect ratios: a phase diagram study using a three-dimensional analytical model , 2012, Microfluidics and nanofluidics.