High frequency volume coils for clinical NMR imaging and spectroscopy

A tuned transmission line resonator has been developed in theory and in practical design for the clinical NMR volume coil application at 4.1 tesla. The distributed circuit transmission line resonator was designed for high frequency, large conductive volume applications where conventional lumped element coil designs perform less efficiently. The resonator design has made use of a resonant coaxial cavity, which could be variably tuned to the Larmor frequency of interest by tunable transmission line elements. Large head‐ and body‐sized volumes, high efficiencies, and broad tuning ranges have been shown to be characteristic of the transmission line resonator to frequencies of 500 MHz. The B1 homogeneity of the resonator has been demonstrated to be a function of the electromagnetic properties of the load itself. By numerically solving Maxwell's: equations for the fully time‐dependent B1 field, coil homogeneity was predicted with finite‐element models of anatomic structure, and inhomogeneities corrected for. A how‐to exposition of coil design and construction has been included. Simple methods of quadrature driving and double tuning the transmission line resonator have also been presented. Human head images obtained with a tuned transmission line resonator at 175 MHz have clearly demonstrated uncompromised high field advantages of signal‐to‐noise and spatial resolution.

[1]  D. Mitchell,et al.  Cirrhosis: Multiobserver analysis of hepatic MR imaging findings in a heterogeneous population , 1993, Journal of magnetic resonance imaging : JMRI.

[2]  R. Ladebeck,et al.  In vivo magnetic resonance imaging and spectroscopy of humans with a 4 t whole‐body magnet , 1990, NMR in biomedicine.

[3]  J. Tropp The theory of the bird-cage resonator , 1989 .

[4]  P. Röschmann,et al.  Spectroscopy and imaging with a 4 tesla whole‐body mr system , 1988, NMR in biomedicine.

[5]  Eleanor G. Hall Book Review: Education of the Gifted and Talented , 1986 .

[6]  W. Barber,et al.  Comparison of linear and circular polarization for magnetic resonance imaging , 1985 .

[7]  Jr. R. Wyndrum Microwave filters, impedance-matching networks, and coupling structures , 1965 .

[8]  R. Harrington Time-Harmonic Electromagnetic Fields , 1961 .

[9]  J T Vaughan,et al.  High resolution neuroimaging at 4.1T. , 1995, Magnetic resonance imaging.

[10]  Jullie W Pan,et al.  High frequency coils for clinical nuclear magnetic resonance imaging and spectroscopy , 1993 .

[11]  P. Cahill,et al.  Explicit treatment of mutual inductance in eight-column birdcage resonators. , 1992, Magnetic resonance imaging.

[12]  F. Duck Physical properties of tissue , 1990 .

[13]  A. Chapman,et al.  Elements of Microwave Engineering , 1986 .

[14]  Samuel Y. Liao,et al.  Microwave Devices and Circuits , 1980 .

[15]  P. Dullenkopf,et al.  Slotted tube resonator: A new NMR probe head at high observing frequencies , 1977 .

[16]  Robert A. Chipman,et al.  Schaum's outline of theory and problems of transmission lines , 1968 .