Dynamic Parameter Optimization and Experimental Study of Tuned Slab Damper on Metro Systems

With the increase of axle weight and speed, the interaction between vehicles and the track becomes more and more intense, and the problem of wheel-rail dynamic action is more serious. In order to reduce the low-frequency vibration caused by train operation, a three-layer elastic track damping structure is proposed. The complex method is used to optimize the dynamic parameters, structural patterns, and coupling relations of the track structure, which allows multiple elastic units to work in harmony with each other to achieve the effects of absorbing vibration energy and reducing vibration transmission. Finally, a real size model experimental platform is set up to verify the dynamic parameter optimization results. The results show that the vertical mode of the main track system of the coupling-tuned slab damper-floating slab is 26.898 Hz close to the train excitation frequency, and the corresponding equivalent mass is 6074.53 kg. The amplitude of the vibration components in the 20∼40 Hz band can be reduced to 41.8% by using the complex method. The maximum insertion loss is about 10 dB, and the vibration of low-frequency band is not amplified.

[1]  N. Gil-Negrete,et al.  Constrained Layer Damper Modelling and Performance Evaluation for Eliminating Squeal Noise in Trams , 2014 .

[2]  Hua Yan,et al.  Low-frequency vibration control of floating slab tracks using dynamic vibration absorbers , 2015 .

[3]  K. Bathe,et al.  Stability and accuracy analysis of direct integration methods , 1972 .

[4]  Edward L. Wilson,et al.  Numerical methods in finite element analysis , 1976 .

[5]  David Thompson,et al.  Ground Vibration from Trains: Experimental Parameter Characterization and Validation of a Numerical Model , 2011 .

[6]  C. F. Ng,et al.  The effects of floating slab bending resonances on the vibration isolation of rail viaduct , 2009 .

[7]  Anbin Wang,et al.  A test rig to investigate slab track structures for controlling ground vibration , 2006 .

[8]  S Wolf Potential low frequency ground vibration (<6.3 Hz) impacts from underground LRT operations , 2003 .

[9]  Fangsen Cui,et al.  The effectiveness of floating slab track system — Part I. Receptance methods , 2000 .

[10]  M. Osama Al-Hunaidi,et al.  Digital frequency-weighting filters for evaluation of human exposure to building vibration , 1996 .

[11]  Guanghui Xu,et al.  Research on Test Method and Dynamic Characteristics of the Rail System with Multi-player Elastic Components , 2018 .

[12]  L. G. Jaeger,et al.  Dynamics of structures , 1990 .

[13]  Geert Lombaert,et al.  The control of ground-borne vibrations from railway traffic by means of continuous floating slabs , 2006 .

[14]  Edward L. Wilson,et al.  Nonlinear dynamic analysis of complex structures , 1972 .

[15]  David Thompson,et al.  Decay rates of propagating waves in railway tracks at high frequencies , 2009 .