Properties of preprocessed sinogram data in x-ray computed tomography.

The accurate determination of x-ray signal properties is important to several computed tomography (CT) research and development areas, notably for statistical reconstruction algorithms and dose-reduction simulation. The most commonly used model of CT signal formation, assuming monoenergetic x-ray sources with quantum counting detectors obeying simple Poisson statistics, does not reflect the actual physics of CT acquisition. This paper describes a more accurate model, taking into account the energy-integrating detection process, nonuniform flux profiles, and data-conditioning processes. Methods are developed to experimentally measure and theoretically calculate statistical distributions, as well as techniques to analyze CT signal properties. Results indicate the limitations of current models and suggest improvements for the description of CT signal properties.

[1]  M. A. Bouman,et al.  Spatial Modulation Transfer in the Human Eye , 1967 .

[2]  S J Riederer,et al.  Noise Due to Photon Counting Statistics in Computed X‐Ray Tomography , 1977, Journal of computer assisted tomography.

[3]  R Birch,et al.  Computation of bremsstrahlung X-ray spectra and comparison with spectra measured with a Ge(Li) detector. , 1979, Physics in medicine and biology.

[4]  D. Morgenthaler,et al.  Noise factor of a polyenergetic x-ray beam in computed tomography. , 1980, Physics in medicine and biology.

[5]  S L Fritz,et al.  A comparison of computed and measured heel effect for various target angles. , 1982, Medical physics.

[6]  Andreas Höfer,et al.  Ein Programm für die Berechnung von diagnostischen Röntgenspektren , 1985 .

[7]  M. Rabbani,et al.  Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[8]  Majid Rabbani,et al.  Analysis of signal and noise propagation for several imaging mechanisms , 1989 .

[9]  R Van Metter,et al.  An application of multivariate moment-generating functions to the analysis of signal and noise propagation in radiographic screen-film systems. , 1990, Medical physics.

[10]  D R Dance,et al.  Monte Carlo study of grid performance in diagnostic radiology: factors which affect the selection of tube potential and grid ratio. , 1993, The British journal of radiology.

[11]  R. F. Wagner,et al.  SNR and noise measurements for medical imaging: I. A practical approach based on statistical decision theory. , 1993, Physics in medicine and biology.

[12]  A. Leung,et al.  Simulated dose reduction in conventional chest CT: validation study. , 1997, Radiology.

[13]  W A Kalender,et al.  Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studies. , 1999, Medical physics.

[14]  Holger Greess,et al.  Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers , 1999, European Radiology.

[15]  M Danielsson,et al.  Detective quantum efficiency dependence on x-ray energy weighting in mammography. , 1999, Medical physics.

[16]  Joseph A O'Sullivan,et al.  Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction. , 2002, Medical physics.

[17]  Jeffrey A. Fessler,et al.  Statistical image reconstruction for polyenergetic X-ray computed tomography , 2002, IEEE Transactions on Medical Imaging.

[18]  C.W.J. Beenakker,et al.  Quantum shot noise , 2003 .

[19]  J. Marchal Extension of x-ray imaging linear systems analysis to detectors with energy discrimination capability. , 2005, Medical physics.

[20]  T. Mulkens,et al.  Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. , 2005, Radiology.