Estimation of the shear force in Transverse Dynamic Force Microscopy using a sliding mode observer

This paper concerns the application of a sliding mode observer to the problem of estimation of the shear force affecting the cantilever dynamics of a Transverse Dynamic Force Microscope (TDFM). The oscillated cantilever in proximity to a specimen permits the investigation of the specimen topography at nano-metre precision. The oscillation amplitude, but also in particular the shear forces, are a measure of distance to the specimen, and therefore the estimation of the shear force is of significance when attempting to construct TDFM images at submolecular accuracy. For estimation of the shear forces, an approximate model of the cantilever is derived using the method of lines. Model order reduction and sliding mode techniques are employed to reconstruct the unknown shear force affecting the cantilever dynamics based on only tip position measurements. Simulations are presented to illustrate the proposed scheme, which is to be implemented on the TDFM set up at the Centre for NSQI at Bristol.

[1]  William E. Schiesser,et al.  A Compendium of Partial Differential Equation Models: Method of Lines Analysis with Matlab , 2009 .

[2]  B. Moore Principal component analysis in linear systems: Controllability, observability, and model reduction , 1981 .

[3]  R. Colton,et al.  Measuring the nanomechanical properties and surface forces of materials using an atomic force microscope , 1989 .

[4]  Kathy L. Rowlen,et al.  Tip Characterization from AFM Images of Nanometric Spherical Particles , 1998 .

[5]  Othmar Marti,et al.  Influence of environmental conditions on shear–force distance control in near-field optical microscopy , 1999 .

[6]  A Ulcinas,et al.  A new detection system for extremely small vertically mounted cantilevers , 2008, Nanotechnology.

[7]  Guido Herrmann,et al.  Cantilever dynamics modelling for the Transverse Dynamic Force Microscope , 2014, 53rd IEEE Conference on Decision and Control.

[8]  D. Courjon,et al.  Influence of the water layer on the shear force damping in near-field microscopy , 1998 .

[9]  Murti V. Salapaka,et al.  Real-time detection of probe loss in atomic force microscopy , 2006 .

[10]  Toshio Ando,et al.  High-Speed Atomic Force Microscopy , 2012, Microscopy.

[11]  Chee Pin Tan,et al.  Sliding mode observers for fault detection and isolation , 2002 .

[12]  Jonathan D. Adams,et al.  Components for high speed atomic force microscopy. , 2006, Ultramicroscopy.

[13]  Halim Alwi,et al.  Sliding mode estimation schemes for incipient sensor faults , 2009, Autom..

[14]  S. Sastry,et al.  Adaptive Control: Stability, Convergence and Robustness , 1989 .

[15]  William E. Schiesser,et al.  A Compendium of Partial Differential Equation Models: Frontmatter , 2009 .

[16]  Athanasios C. Antoulas,et al.  Approximation of Large-Scale Dynamical Systems , 2005, Advances in Design and Control.

[17]  Richard M. Murray,et al.  Feedback Systems An Introduction for Scientists and Engineers , 2007 .

[18]  Christopher Edwards,et al.  On the solvability of the constrained Lyapunov problem , 2007, 2006 American Control Conference.

[19]  M. Antognozzi,et al.  Modeling of cylindrically tapered cantilevers for transverse dynamic force microscopy (TDFM). , 2001, Ultramicroscopy.

[20]  Javier Tamayo,et al.  Interpretation of phase contrast in tapping mode AFM and shear force microscopy: a study of Nafion , 2001 .

[21]  Massimo Antognozzi,et al.  Observation of molecular layering in a confined water film and study of the layers viscoelastic properties , 2001 .

[22]  Marouane Alma,et al.  On observer-based estimation enhancement by parametric amplification in a weak force measurement device , 2008, 2008 47th IEEE Conference on Decision and Control.

[23]  Georg Schitter,et al.  Improving the Imaging Speed of AFM with Modern Control Techniques , 2011 .

[24]  L. Fridman,et al.  Higher‐order sliding‐mode observer for state estimation and input reconstruction in nonlinear systems , 2008 .

[25]  Christopher Edwards,et al.  Robust Fault Reconstruction in Uncertain Linear Systems Using Multiple Sliding Mode Observers in Cascade , 2010, IEEE Transactions on Automatic Control.

[26]  Yuri B. Shtessel,et al.  Sliding mode parameter identification of systems with measurement noise , 2007, Int. J. Syst. Sci..

[27]  A Ulcinas,et al.  Micro-fabricated mechanical sensors for lateral molecular-force microscopy. , 2011, Ultramicroscopy.

[28]  T. Ando Control techniques in high-speed atomic force microscopy , 2008, 2008 American Control Conference.

[29]  Gerber,et al.  Atomic Force Microscope , 2020, Definitions.

[30]  Christopher Edwards,et al.  Sliding mode control : theory and applications , 1998 .

[31]  Christopher Edwards,et al.  SLIDING MODE OUTPUT TRACKING WITH APPLICATION TO A MULTIVARIABLE HIGH TEMPERATURE FURNACE PROBLEM , 1997 .

[32]  Christopher Edwards,et al.  Nonlinear robust fault reconstruction and estimation using a sliding mode observer , 2007, Autom..

[33]  Guido Herrmann,et al.  Estimation of the shear force in Transverse Dynamic Force Microscopy using a sliding mode observer , 2013, ACC.

[34]  S. Żak,et al.  State observation of nonlinear uncertain dynamical systems , 1987 .

[35]  L. Fridman,et al.  High-Order Sliding-Mode Observation and Identification for Linear Systems with Unknown Inputs , 2006, Proceedings of the 45th IEEE Conference on Decision and Control.

[36]  J. Hörber,et al.  Methods for imaging DNA in liquid with lateral molecular-force microscopy , 2012, Nanotechnology.

[37]  Christopher Edwards,et al.  Sliding mode observers for reconstruction of simultaneous actuator and sensor faults , 2003, 42nd IEEE International Conference on Decision and Control (IEEE Cat. No.03CH37475).

[38]  Arvind Raman,et al.  Accurate force spectroscopy in tapping mode atomic force microscopy in liquids , 2010 .

[39]  T. Ando,et al.  High-speed atomic force microscopy for nano-visualization of dynamic biomolecular processes , 2008 .