Ultrasonic Measurement of Fine Head Movements in a Standard Ophthalmic Headrest

We aimed to investigate the naturally occurring horizontal plane movements of a head stabilized in a standard ophthalmic headrest and to analyze their magnitude, velocity, spectral characteristics, and correlation to the cardio pulmonary system. Two custom-made air-coupled highly accurate (±2 ¿m) ultrasound transducers were used to measure the displacements of the head in different horizontal directions with a sampling frequency of 100 Hz. Synchronously to the head movements, an electrocardiogram (ECG) signal was recorded. Three healthy subjects participated in the study. Frequency analysis of the recorded head movements and their velocities was carried out, and functions of coherence between the two displacements and the ECG signal were calculated. Frequency of respiration and the heartbeat were clearly visible in all recorded head movements. The amplitude of head displacements was typically in the range of ±100 ¿m. The first harmonic of the heartbeat (in the range of 2-3 Hz), rather than its principal frequency, was found to be the dominant frequency of both head movements and their velocities. Coherence analysis showed high interdependence between the considered signals for frequencies of up to 20 Hz. These findings may contribute to the design of better ophthalmic headrests and should help other studies in the decision making of whether to use a heavy headrest or a bite bar.

[1]  H. Kasprzak,et al.  Dynamics in longitudinal eye movements and corneal shape , 2006, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.

[2]  J. Mizrahi,et al.  Postural stability in stroke patients: Vectorial expression of asymmetry, sway activity and relative sequence of reactive forces , 1989, Medical and Biological Engineering and Computing.

[3]  D. R. Iskander,et al.  Ocular Microfluctuations and Videokeratoscopy , 2002, Cornea.

[4]  Péter Gáspár,et al.  High-speed videotopographic measurement of tear film build-up time. , 2002, Investigative ophthalmology & visual science.

[5]  D. R. Iskander,et al.  Spectral characteristics of longitudinal corneal apex velocities and their relation to the cardiopulmonary system , 2007, Eye.

[6]  F. Gueuning,et al.  Accurate distance measurement by an autonomous ultrasonic system combining time-of-flight and phase-shift methods , 1996, Quality Measurement: The Indispensable Bridge between Theory and Reality (No Measurements? No Science! Joint Conference - 1996: IEEE Instrumentation and Measurement Technology Conference and IMEKO Tec.

[7]  P Artal,et al.  Dynamics of the eye's wave aberration. , 2001, Journal of the Optical Society of America. A, Optics, image science, and vision.

[8]  D. O'leary,et al.  High-frequency autorotational testing of the vestibulo-ocular reflex. , 1990, Neurologic clinics.

[9]  G.C.Y. Peng,et al.  Predicting vestibular, proprioceptive, and biomechanical control strategies in normal and pathological head movements , 1999, IEEE Transactions on Biomedical Engineering.

[10]  B W Peterson,et al.  Mechanisms controlling human head stabilization. II. Head-neck characteristics during random rotations in the vertical plane. , 1995, Journal of neurophysiology.

[11]  Mark R. Morelande,et al.  Analyzing the dynamic wavefront aberrations in the human eye , 2004, IEEE Transactions on Biomedical Engineering.

[12]  W P Medendorp,et al.  Human gaze stabilization during active head translations. , 2002, Journal of neurophysiology.

[13]  Stefan Eberl,et al.  A practical 3D tomographic method for correcting patient head motion in clinical SPECT , 1998 .

[14]  Yoshinobu Ebisawa A pilot study on ultrasonic sensor-based measurement of head movement , 2002, IEEE Trans. Instrum. Meas..

[15]  Hikaru Inooka,et al.  Identification of the head-neck complex in response to trunk horizontal vibration , 2004, Biological Cybernetics.

[16]  L. Stark,et al.  Effect of External Viscous Load on Head Movement , 1984, IEEE Transactions on Biomedical Engineering.

[17]  D. R. Iskander,et al.  Applications of high‐speed videokeratoscopy , 2005, Clinical & experimental optometry.

[18]  D. Webster A pulsed ultrasonic distance measurement system based upon phase digitizing , 1994 .

[19]  J. Zuckerman,et al.  Noncontact detection of ocular pulse--correlation with carotid stenosis. , 1977, Investigative ophthalmology & visual science.