The electronic evaluation of fetal heart rate

Abstract 1.1. Modern electronic techniques provide a more accurate indication of the fetal heart rate during normal and abnormal labor than it is possible to obtain by present clinical methods. 2.2. With normal breech presentations and the majority of vertex presentations studied, the fetal heart rate does not slow significantly with contractions. 3.3. In the minority of vertex presentations, usually in primigravidas, the instantaneous fetal heart rate may drop as low as 60 to 70 beats per minute and may return to normal 10 to 15 seconds before the contraction is over. 4.4. In vertex presentations, fetal bradycardia with contractions is probably related to an increase in intracranial pressure which in turn is related to the amount of cervical dilatation present. 5.5. A preliminary evaluation of a working clinical hypothesis based on changes in the instantaneous fetal heart rate suggests the possibility of a more sensitive index of fetal distress.

[1]  S. J. Ginsburg The Significance of the Signs of Fetal Distress , 1957 .

[2]  S. R. Reynolds,et al.  Bradycardia in the lamb fetus in response to circulatory distress. , 1953, The American journal of physiology.

[3]  E. Taylor,et al.  A comparative study of the disappearance of radioactive sodium from human uterine muscle in normal and abnormal pregnancy. , 1958, American journal of obstetrics and gynecology.

[4]  C. J. Lund,et al.  The use of heroin (diacetyl-morphine) in labor , 1943 .

[5]  A. Mogg,et al.  CARDIAC ARRHYTHMIA: EFFECT OF VAGAL STIMULATION AND HYPOXIA , 1955, Anesthesiology.

[6]  S. R. Reynolds,et al.  Relation of bradycardia and blood pressure of the fetal lamb in utero to mild and severe hypoxia. , 1958, The American journal of physiology.

[7]  L. Schamroth Electrocardiographic effects of eyeball compression. , 1958, The American journal of cardiology.

[8]  J. Mccall,et al.  A study of fetal distress, its interpretation and significance. , 1953, American journal of obstetrics and gynecology.

[9]  E. L. King Some observations regarding the fetal heart tones and the presence of meconium during the course of labor , 1940 .

[10]  Kilner Tp Repair of skin defects. , 1947 .

[11]  R. Bernstine,et al.  Prenatal fetal electrocardiography. , 1955, American journal of obstetrics and gynecology.

[12]  N. Veall,et al.  THE MATERNAL PLACENTAL BLOOD FLOW IN NORMOTENSIVE AND HYPERTENSIVE WOMEN , 1953, The Journal of obstetrics and gynaecology of the British Empire.

[13]  P. Vara,et al.  [Fetal electrocardiography]. , 1953, Die Medizinische.

[14]  S. R. Reynolds,et al.  Hemodynamic characteristics of the fetal circulation. , 1954, American journal of obstetrics and gynecology.

[15]  J. Donnelly,et al.  [The induction of premature labor by means of pitocin in patients with toxemia of pregnancy]. , 1952, American journal of obstetrics and gynecology.

[16]  P. Vara,et al.  On Foetal Electrocardiography. II , 1952, Acta obstetricia et gynecologica Scandinavica.

[17]  W. C. Keettel,et al.  The hazards of elective induction of labor. , 1958, American journal of obstetrics and gynecology.

[18]  C. Flowers,et al.  Perinatal mortality in the North Carolina Memorial Hospital, 1952-1958. , 1959, Journal of the American Medical Association.

[19]  E. Southern,et al.  Fetal anoxia and its possible relation to changes in the prenatal fetal electrocardiogram. , 1957, American journal of obstetrics and gynecology.

[20]  A. Master THE ELECTROCARDIOGRAM AND THE “TWO‐STEP” EXERCISE: A Test of Cardiac Function and Coronary Insufficiency*† , 1944 .

[21]  C. J. Lund The Recognition and Treatment of Fetal Heart Arrhythmias due to Anoxia , 1940 .

[22]  J. Lanman Physiology of Prematurity , 1958, The Yale Journal of Biology and Medicine.

[23]  J. Walker,et al.  Haemoglobin and red cells in the human foetus and their relation to the oxygen content of the blood in the vessels of the umbilical cord. , 1953, Lancet.

[24]  E. Hon,et al.  Instrumentation of fetal electrocardiography. , 1957, Science.

[25]  C. G. Clayton,et al.  STUDIES IN PLACENTAL ACTION DURING PROLONGED AND DYSFUNCTIONAL LABOURS USING RADIOACTIVE SODIUM , 1955, The Journal of obstetrics and gynaecology of the British Empire.

[26]  J. Barcroft Researches on Pre-Natal Life , 1947 .

[27]  S. Osborn,et al.  EFFECTIVE UTERINE BLOOD‐FLOW DURING EXERCISE IN NORMAL AND PRE‐ECLAMPTIC PREGNANCIES , 1956 .

[28]  L. Hellman Factors influencing successful posterior pituitary treatment of functional uterine dystocia with particular consideration of its intravenous administration. , 1949, American journal of obstetrics and gynecology.

[29]  D A HOLADAY,et al.  The acid-base status of human infants in relation to birth asphyxia and the onset of respiration. , 1958, The Journal of pediatrics.

[30]  E. Hon The fetal heart rate patterns preceding death in utero. , 1959, American journal of obstetrics and gynecology.

[31]  Frederick C. Freed Clinical signs of fetal distress during labor , 2022 .

[32]  E. Southern,et al.  ELECTROCARDIOGRAPHY AND PHONOCARDIOGRAPHY OF THE FOETAL HEART , 1954, The Journal of obstetrics and gynaecology of the British Empire.

[33]  E. Hon,et al.  The electronic evaluation of fetal heart rate. II. Changes with maternal hypotension. , 1960, American journal of obstetrics and gynecology.

[34]  OBSERVATIONS ON “PATHOLOGIC” FETAL BRADYCARDIA , 1959, American journal of obstetrics and gynecology.

[35]  G. Dawes,et al.  Oxygen lack and autonomic nervous control of the foetal circulation in the lamb , 1956, The Journal of physiology.

[36]  B. Ranney Intravenous pitocin infusion. , 1957, Obstetrics and gynecology.

[37]  R. Bartholomew Clinical interpretation and importance of the fetal heart sounds during labor , 1925 .

[38]  A. Greenfield,et al.  Cardiovascular responses to asphyxia in the foetal guinea‐pig , 1953, The Journal of physiology.

[39]  C. J. Lund Fetal tachycardia during labor , 1943 .

[40]  S. Osborn,et al.  Effective uterine blood flow during labor. , 1958, American journal of obstetrics and gynecology.

[41]  S. Osborn,et al.  Effective circulation of the uterine wall in late pregnancy measured with 24NaCl. , 1955, Lancet.

[42]  H. Mann,et al.  A clinical evaluation of fetal electrocardiography , 1942 .

[43]  T. Montgomery Physiologic considerations in labor and the puerperium. , 1958, American journal of obstetrics and gynecology.

[44]  R. M. Samuel,et al.  CLINICAL MEASUREMENT OF UTERINE FORCES IN PREGNANCY AND LABOR , 1955 .

[45]  P. T. Moore,et al.  CLEARANCE RATES OF RADIOSODIUM FROM MYOMETRIUM , 1957, The Journal of obstetrics and gynaecology of the British Empire.

[46]  L. Cox,et al.  THE EFFECT OF PRE‐ECLAMPTIC TOXAEMIA ON THE EXCHANGE OF SODIUM IN THE BODY AND THE TRANSFER OF SODIUM ACROSS THE PLACENTA, MEASURED BY Na24 TRACER METHODS , 1953, The Journal of obstetrics and gynaecology of the British Empire.

[47]  R. Mackay OBSERVATIONS ON THE OXYGENATION OF THE FOETUS IN NORMAL AND ABNORMAL PREGNANCY , 1957, The Journal of obstetrics and gynaecology of the British Empire.

[48]  R. D. Mussey,et al.  Technic and results of routine fetal electrocardiography during pregnancy , 1938 .

[49]  A. Master The two-step test of myocardial function☆ , 1935 .

[50]  A. Master,et al.  A SIMPLE EXERCISE TOLERANCE TEST FOR CIRCULATORY EFFICIENCY WITH STANDARD TABLES FOR NORMAL INDIVIDUALS , 1929 .

[51]  W. Hamilton,et al.  THE RELATIONSHIP BETWEEN ABDOMINAL, UTERINE AND ARTERIAL PRESSURES DURING LABOR , 1938 .

[52]  C. Hendricks The hemodynamics of a uterine contraction. , 1958, American journal of obstetrics and gynecology.

[53]  W. Tolles,et al.  Studies in fetal well-being: variations in fetal heart rate. , 1958, American journal of obstetrics and gynecology.

[54]  T. B. Fitzgerald,et al.  Foetal Distress and Intra-partum Foetal Death , 1955, British medical journal.

[55]  E. Hon,et al.  The electronic evaluation of fetal heart rate. 3. The effect of an oxytocic agent used for the induction of labor. , 1960, American Journal of Obstetrics and Gynecology.