Investigation of the Frequency Shift of a SAD Circuit Loop and the Internal Micro-Cantilever in a Gas Sensor

Micro-cantilever sensors for mass detection using resonance frequency have attracted considerable attention over the last decade in the field of gas sensing. For such a sensing system, an oscillator circuit loop is conventionally used to actuate the micro-cantilever, and trace the frequency shifts. In this paper, gas experiments are introduced to investigate the mechanical resonance frequency shifts of the micro-cantilever within the circuit loop(mechanical resonance frequency, MRF) and resonating frequency shifts of the electric signal in the oscillator circuit (system working frequency, SWF). A silicon beam with a piezoelectric zinc oxide layer is employed in the experiment, and a Self-Actuating-Detecting (SAD) circuit loop is built to drive the micro-cantilever and to follow the frequency shifts. The differences between the two resonating frequencies and their shifts are discussed and analyzed, and a coefficient α related to the two frequency shifts is confirmed.

[1]  A. Hierlemann,et al.  Complementary metal oxide semiconductor cantilever arrays on a single chip: mass-sensitive detection of volatile organic compounds. , 2002, Analytical chemistry.

[2]  Todd Sulchek,et al.  Mercury vapor detection with a self-sensing, resonating piezoelectric cantilever , 2003 .

[3]  Olivier Français,et al.  Chemical sensing: millimeter size resonant microcantilever performance , 2004 .

[4]  G. Fedder,et al.  CMOS MEMS oscillator for gas chemical detection , 2004, Proceedings of IEEE Sensors, 2004..

[5]  C. Vancura,et al.  Magnetically actuated complementary metal oxide semiconductor resonant cantilever gas sensor systems. , 2005, Analytical chemistry.

[6]  Christoph Hagleitner,et al.  Monolithic CMOS multi-transducer gas sensor microsystem for organic and inorganic analytes , 2007 .

[7]  T. Thundat,et al.  Measurement of Mechanical Properties of Cantilever Shaped Materials , 2008, Sensors.

[8]  Angel Ríos,et al.  Micro-electromechanical sensors in the analytical field. , 2009, The Analyst.

[9]  Ryutaro Maeda,et al.  Characterization and improvement on quality factor of microcantilevers with self-actuation and self-sensing capability , 2009 .

[10]  Hai-Feng Ji,et al.  Mechanical and electronic approaches to improve the sensitivity of microcantilever sensors , 2009, Acta mechanica Sinica = Li xue xue bao.

[11]  Anja Boisen,et al.  Cantilever Sensors: Nanomechanical Tools for Diagnostics , 2009 .

[12]  Pengcheng Xu,et al.  Resonant-cantilever bio/chemical sensors with an integrated heater for both resonance exciting optimization and sensing repeatability enhancement , 2009 .

[13]  Zheng You,et al.  Resonating Frequency of a SAD Circuit Loop and Inner Microcantilever in a Gas Sensor , 2010, IEEE Sensors Journal.