VCE early acoustic test results of General Electric's high-radius ratio coannular plug nozzle
暂无分享,去创建一个
Results of variable cycle engine (VCE) early acoustic engine and model scale tests are presented. A summary of an extensive series of far field acoustic, advanced acoustic, and exhaust plume velocity measurements with a laser velocimeter of inverted velocity and temperature profile, high radius ratio coannular plug nozzles on a YJ101 VCE static engine test vehicle are reviewed. Select model scale simulated flight acoustic measurements for an unsuppressed and a mechanical suppressed coannular plug nozzle are also discussed. The engine acoustic nozzle tests verify previous model scale noise reduction measurements. The engine measurements show 4 to 6 PNdB aft quadrant jet noise reduction and up to 7 PNdB forward quadrant shock noise reduction relative to a fully mixed conical nozzle at the same specific thrust and mixed pressure ratio. The influences of outer nozzle radius ratio, inner stream velocity ratio, and area ratio are discussed. Also, laser velocimeter measurements of mean velocity and turbulent velocity of the YJ101 engine are illustrated. Select model scale static and simulated flight acoustic measurements are shown which corroborate that coannular suppression is maintained in forward speed.
[1] Meyer J. Benzakein,et al. Supersonic Jet Exhaust Noise. , 1972 .
[2] Paul R Knott. Supersonic Jet Exhaust Noise Investigation , 1974 .
[3] P. H. Heck,et al. Acoustic tests of duct-burning turbofan jet noise simulation: Comprehensive data report. Volume 1, section 1: Model scale data , 1978 .
[4] James R. Stone. An improved method for predicting the effects of flight on jet mixing noise , 1979 .