Monodisperse and Polydisperse Aerosol Deposition in a Packed Bed

Although polydisperse aerosols in ambient and occupational settings have been associated with adverse health effects, researchers have mostly used monodisperse aerosols to investigate particle deposition in the human lung. The objective of this work was to determine whether the deposition of a series of monodisperse aerosols is reasonable to simulate the deposition of a polydisperse aerosol. A packed bed was used as an approximate surrogate to the human lung. Polydisperse and monodisperse sebacate aerosols were generated by nebulizers and a Monodisperse Aerosol Generator (MAGE), respectively. A Harvard respirator pump "inhaled" and "exhaled" aerosol through the packed bed. Complete size distributions of inhaled and exhaled aerosol were measured by an Aerodynamic Particle Sizer (APS) and a Scanning Mobility Particle Sizer (SMPS). The deposition for discrete sections of polydisperse aerosols was compared with the deposition of monodisperse aerosols. Also, the total deposition of a polydisperse aerosol was compared with the deposition of a series of monodisperse aerosols that formed the same size distribution as the polydisperse aerosol. Experiments were run with and without a charge neutralizer. With the neutralizer, no difference in deposition occurred between the discrete sections of polydisperse and monodisperse aerosols. Thus, total deposition was the same for both a polydisperse and a series of monodisperse aerosols, indicating that a series of monodisperse aerosols is reasonable to represent a polydisperse aerosol. Without a charge neutralizer, discrete sections of polydisperse aerosols with particle diameters of 3 w m or greater deposited no differently than they did with a neutralizer. However, for particle diameters of 1 w m or less, deposition of discrete sections of polydisperse aerosols was greater than that of monodisperse aerosols. Thus, total deposition was greater for polydisperse aerosols than for a series of monodisperse aerosols, indicating the need to condition aerosol with a neutralizer after the nebulization of a sebacate/alcohol solution.

[1]  C. Kim,et al.  Assessment of regional deposition of inhaled particles in human lungs by serial bolus delivery method. , 1996, Journal of applied physiology.

[2]  Chong S. Kim,et al.  Particle Deposition in Cyclic Bifurcating Tube Flow , 1991 .

[3]  Parker C. Reist,et al.  Aerosol science and technology , 1993 .

[4]  D. House,et al.  Dispersion of aerosol boluses in the human lung: dependence on lung volume, bolus volume, and gender. , 1995, Journal of applied physiology.

[5]  M. Lippmann,et al.  Particle deposition within bronchial airways: comparisons using constant and cyclic inspiratory flows. , 1982, The Annals of occupational hygiene.

[6]  J. Heyder,et al.  Removal of aerosol particles from stationary air within porous media , 1985 .

[7]  E. Karg,et al.  Estimation of deposition of polydisperse hygroscopic aerosols in the human respiratory tract , 1993 .

[8]  K. Okuyama,et al.  MEASUREMENT OF ELECTRIC CHARGE OF AEROSOL PARTICLES GENERATED BY VARIOUS METHODS , 1981 .

[9]  M. L. Laucks Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles , 2000 .

[10]  J. Heyder,et al.  The Use of Light Scattering Photometry in Aerosol Medicine , 1988 .

[11]  D. Dockery,et al.  An association between air pollution and mortality in six U.S. cities. , 1993, The New England journal of medicine.

[12]  A M Weirich,et al.  The deposition. , 1996, Home healthcare nurse.

[13]  R. D. Miller,et al.  Characterization of a condensation-type monodisperse aerosol generator (MAGE) , 1991 .

[14]  D. Dockery,et al.  Acute respiratory effects of particulate air pollution. , 1994, Annual review of public health.

[15]  J. Heyder,et al.  Total deposition of aerosol particles in the human respiratory tract for nose and mouth breathing , 1975 .

[16]  Benjamin Y. H. Liu,et al.  Particle Charge Distribution Measurement for Commonly Generated Laboratory Aerosols , 1998 .

[17]  David C.F. Muir,et al.  The Deposition of 0·5 µ Diameter Aerosols in the Lungs of Man , 1967 .

[18]  James S. Brown,et al.  A polydisperse aerosol inhalation system designed for human studies , 2002 .

[19]  P. Anderson,et al.  Aerosol bolus dispersion and convective mixing in human and dog lungs and physical models. , 1992, Journal of applied physiology.

[20]  J. Heyder,et al.  Aerosol transport in the human lung from analysis of single breaths. , 1978, Journal of applied physiology: respiratory, environmental and exercise physiology.