An Lp (0 ≤ p ≤ 1)-norm regularized image reconstruction scheme for breast DOT with non-negative-constraint

BackgroundIn diffuse optical tomography (DOT), the image reconstruction is often an ill-posed inverse problem, which is even more severe for breast DOT since there are considerably increasing unknowns to reconstruct with regard to the achievable number of measurements. One common way to address this ill-posedness is to introduce various regularization methods. There has been extensive research regarding constructing and optimizing objective functions. However, although these algorithms dramatically improved reconstruction images, few of them have designed an essentially differentiable objective function whose full gradient is easy to obtain to accelerate the optimization process.MethodsThis paper introduces a new kind of non-negative prior information, designing differentiable objective functions for cases of L1-norm, Lp (0 < p < 1)-norm and L0-norm. Incorporating this non-negative prior information, it is easy to obtain the gradient of these differentiable objective functions, which is useful to guide the optimization process.ResultsPerformance analyses are conducted using both numerical and phantom experiments. In terms of spatial resolution, quantitativeness, gray resolution and execution time, the proposed methods perform better than the conventional regularization methods without this non-negative prior information.Conclusions The proposed methods improves the reconstruction images using the introduced non-negative prior information. Furthermore, the non-negative constraint facilitates the gradient computation, accelerating the minimization of the objective functions.

[1]  A. V. Schaik,et al.  L1 regularization method in electrical impedance tomography by using the L1-curve (Pareto frontier curve) , 2012 .

[2]  Yukio Yamada,et al.  Improvement of image quality of time-domain diffuse optical tomography with lp sparsity regularization , 2011, Biomedical optics express.

[3]  Arye Nehorai,et al.  Image reconstruction for diffuse optical tomography using sparsity regularization and expectation-maximization algorithm. , 2007, Optics express.

[4]  Feng Gao,et al.  A self-normalized, full time-resolved method for fluorescence diffuse optical tomography. , 2008, Optics express.

[5]  Jong Chul Ye,et al.  Compressive Diffuse Optical Tomography: Noniterative Exact Reconstruction Using Joint Sparsity , 2011, IEEE Transactions on Medical Imaging.

[6]  Junzhou Huang,et al.  Diffuse Optical Tomography Enhanced by Clustered Sparsity for Functional Brain Imaging , 2014, IEEE Transactions on Medical Imaging.

[7]  Changqing Li,et al.  Nonconvex regularizations in fluorescence molecular tomography for sparsity enhancement , 2014, Physics in medicine and biology.

[8]  Gabor Fichtinger,et al.  REDMAPS: Reduced-Dimensionality Matching for Prostate Brachytherapy Seed Reconstruction , 2011, IEEE Transactions on Medical Imaging.

[9]  Yuqing Hou,et al.  Improved sparse reconstruction for fluorescence molecular tomography with L1/2 regularization. , 2015, Biomedical optics express.

[10]  Yuying Li,et al.  A computational algorithm for minimizing total variation in image restoration , 1996, IEEE Trans. Image Process..

[11]  S R Arridge,et al.  Three-dimensional time-resolved optical tomography of a conical breast phantom. , 2001, Applied optics.

[12]  Jie Tian,et al.  A fast reconstruction algorithm for fluorescence molecular tomography with sparsity regularization. , 2010, Optics express.

[13]  Feng Gao,et al.  Lock-in-photon-counting-based highly-sensitive and large-dynamic imaging system for continuous-wave diffuse optical tomography. , 2016, Biomedical optics express.

[14]  Mário A. T. Figueiredo,et al.  Gradient Projection for Sparse Reconstruction: Application to Compressed Sensing and Other Inverse Problems , 2007, IEEE Journal of Selected Topics in Signal Processing.

[15]  Marc Teboulle,et al.  A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems , 2009, SIAM J. Imaging Sci..

[16]  Feng Gao,et al.  Determination of optical properties in turbid medium based on time-resolved determination , 2007, International Conference on Photonics and Imaging in Biology and Medicine.

[17]  E.J. Candes,et al.  An Introduction To Compressive Sampling , 2008, IEEE Signal Processing Magazine.

[18]  B. Vojnovic Advanced Time‐Correlated Single Photon Counting Techniques , 2006 .

[19]  Ge Wang,et al.  L(p) regularization for early gate fluorescence molecular tomography. , 2014, Optics letters.

[20]  L. Svaasand,et al.  Non-invasive in vivo characterization of breast tumors using photon migration spectroscopy. , 2000, Neoplasia.

[21]  Christian Jutten,et al.  A Fast Approach for Overcomplete Sparse Decomposition Based on Smoothed $\ell ^{0}$ Norm , 2008, IEEE Transactions on Signal Processing.

[22]  Phaneendra K. Yalavarthy,et al.  Sparse Recovery Methods Hold Promise for Diffuse Optical Tomographic Image Reconstruction , 2014, IEEE Journal of Selected Topics in Quantum Electronics.